Diff. Measuring ranges from 35kPa to 2.5 MPa
Isolated construction, suitable for various fluid medium
Wide suitability and easy operation, soild, reliability
Temperature compensation by laser trimming
Mass production, cost-effective
Constant current or voltage excitationApplications:
Process control systems
Hydraulic systems and valves
Biomedical instruments.
Performance SpecificationElectric PerformancePower supply: ≤2.0mADC
Electric connection: 100mm silicon rubber flexible wires
Common mode voltage input: 50% of input (typ.)
Input impedance: 3kΩ~8kΩ
Output impedance: 3.5kΩ~6kΩ
Response (10%~90%): <1ms
Insulation resistor: 100MΩ, 100VDC
Overpressure: to see Order Guide
Max. static pressure: 20MPa
Zero drift/static pressure: ≤0.5mV/MPaConstruction SpecificationDiaphragm material: stainless steel 316L
Housing: stainless steel 316L
Pin: silicon rubber flexible wire
O-ring: Vinton
Net weight: approx 36gEnvironment ConditionPosition effect: deviate 90° from any orientation, zero change ≤0.2%FS
Shock: no change at 10gRMS,(20~2000)Hz
Impact: 100g, 11ms
Media compatibility: the gas or media which is compatible with stainless steel and VitonBasic ConditionMedia temperature: (25±1)ºC
Environment temperature: (25±1)ºC
Shock: 0.1g (1m/s/s) Max.
Humidity: (50%±10%)RH
Local air pressure: (86~106)kPa
Power supply: (1.5±0.0015)mADCBasic SpecificationSpecification*Min.Typ.Max.UnitsLinearity±0.15±0.25%FS,BFSLRepeatability±0.05±0.075%FSHysteresis±0.05±0.075%FSZero output±3mVDCFS output60mVDCZero thermal error±1.0±1.2%FS, @25ºCSpan thermal error±1.0±1.2%FS, @25ºCCompensated temp. range0~50ºCWorking temp. range-40~125ºCStorage temp. range-40~125ºCLong-term stability±0.3±0.5%FS/year*testing at basic condition
1. The resistance bridge on the left of the dashed is sensor's bridge circuit;
2.The sensor has no laser trimming board, it compensates zero and temperature drift by outer compensated resistors, the connection to see the above chart; connect zero trimming resistor R3(R4), the other R4(R3) is short circuit as negative power supply; R1 or R2 is zero temperature drift compensated resistor, only one of them is used, the other is open circuit, please select the right resistor according to the specification label enclosed with sensor; R5 is sensitivity temperature compensated resistor. We suggest that please connect the outer resistor and differential pressure sensor as close as possible.