Application
Measuring the volume of cold potable water passing through the pipeline
Working conditions
Water temperature :≤50ºC
Water pressure: ≤1.6Mpa
Features
1.mechanical transmission ,
2.dry type register
3.advanced structure
4.internal strainer
Compliance with standard
Technical data conform to ISO 4064 class B
Standard for horizontal installation
Options
Non return valve for selecting except LXS-50E
With threaded ends and with flanged ends
Meter for hot water up to 90ºCis available
Installation requirements
The meter should be installed in horizontal positon With the register face upwards Pipeline must be flushed before installation
The meter should be constantly full of water during operation
Indicating error
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) tooverload flow rate(qs)
Technical dataNominal diameterDNmm152025Inch1/23/41Overall length without connectorsL2mm95100110Overall length with connectorsL1mm170180210Thread meter G x BD1Inch3/411 1/2Thread connector R xD2Inch1/23/41maxm³99,99999,99999,999Maximum temperature°C505050Operating pressure, maxPNbar161616Head loss atQmaxbar111HeightH1mm115120125WidthBmm809595Weightkg1.21.72.5