Business Type:
Trading Company
Business Range:
Laboratory Equipment and Instrument, Medical Equipment
Establishment:
2018
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment
Main Markets:
East Asia(Japan, South Korea), Domestic
OEM/ODM Service
Sample Available

Laminar Air Flow, Flow Bench, Bench Cabinet manufacturer / supplier in China, offering All-Steel Chemical Laboratory Equipment Fume Hood Laboratory, Semi-Exhaust Type Biological Safety Cabinet Research Institute, Semi-Exhaust Type Biological Safety Cabinet Laboratory and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Optical Lens & Instrument Spectrometer Double Beam Atomic Absorption Spectrophotometer Aas for Metal Element

Double Beam Atomic Absorption Spectrophotometer Aas for Metal Element

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $6500.00/ Piece
Local Area: Zhengzhou, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment
Application: Laboratory Apparatus
Warranty: > 1Year
Detection Method: Spectrophotometer
Double beam atomic absorption spectrophotometer AAS for metal elementAtomic absorption spectroscopy (AAS) is a spectroanalytical procedure for the quantitative determination of chemical elements using the absorption of optical radiation (light) by free atoms in the gaseous state. Atomic absorption spectroscopy is based on absorption of light by free metallic ions.AA320N Atomic Absorption Spectrophotometer can be used to measure constant quantity and trace metal elements in various samples through atomic absorption analysis and flame emission analysis by flame method, graphite furnace method and hydride method.
Feature:
Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentrationHigh energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.Parameter:
ModelAA320NWavelength range190-900nmWavelength accuracy≤±0.5nmWavelength repeatability≤0.3nm (single direction)Spectrum bandwidth0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nmResolution<40%base line stability±0.004Abs/30minCharacteristic concentration of copper≤ 0.04μg/ml/1%Detection limit of copper≤0.008μg/mlBackground calibration abilityGreater than 30 timesRS232includingPrinteroptionalPower supply220V 3A, 50HzG.W.160Kg65KgPackage Dimensions1220x770x730mm (Main instrument)800x400x900mm ( Accessories )Options:1. Graphite Furnace Autosampler
2. HGA graphite furnace system
3. Hydride generator
4. Hollow cathode lamp
5. Graphite tube