TECHNICAL PARAMETERS
1. Gas treatment capacity: m3/h, can be designed according to actual requirements from customers.
2.Normal fluegas temperature: 120-180ºC
3.Allowed max gas temperature: 250ºC
4.Allowed dust rate resistance: 104 -1011Ω/cm
5. Flue gas dew point: 60~65ºC
6. Dust concentration at flue gas inlet: <20(g/m3)
7. Dust concentration at flue gas outlet: <50(mg/m3), or to be designed according to requirements.
8. Controls: automatic controlSTANDARD SPECIFICATIONS (EXAMPLE)NO.ITEMSVALUEREMARKS1effective cross sectional area(m2)282Flue gas capacity(m3/h)360003Gas velocity through ESP(m/s)0.364Spacing between collecting plate(mm)4005Length of electric field(m)2*36Number of passages107Type of corona wireBS wire8Rows of corona wire1010Rapping method of corona wiresFlexible arm11Rapping method of collecting plateFlexible arm12Type of collecting plateC48013Rows of collecting plate1114Total area of collecting plate(m2)84015Effective height of collecting plate(m)716Treatment time(s)16.717Allowed pressure (Pa)+200~-500018Pressure drop(Pa)<30019Allowed max flue gas temperature (ºC)25020Dust concentration at flue gas inlet (g/m3)<2021Dust concentration at flue gas outlet (mg/m3)<5022Designed dust collecting efficiency99.5%23High-voltage constant current power supply0.2A/100KVx2 sets
SUCCESSFUL PROJECTS OVERSEAS
1. THAILAND: 5 SETS
2. POLAND: 1SET