Emergency Time: 1 to 3 Hours
Installation: Suspended/Ceiling Mounted/Recessed;
Emergency Indoor&Outdoor Lighting LED Round Panellight System with TUV
Emergency Lighting LED Panels are a functional kit for helping the lamps to make shorter lighting time
when meet special situations after whole power is off and offer people's convenience for actitities in daily life,
especially for life escape, which is done according to international enmergency lighting time& quality standards.
Specification:
Part No.CCT availableSize(mm)PowerEmergency PowerEmergency TimeCRIFunctionLS-01-PL30302800K-6500K295x295mm18W5W/6W/7W/15W1-3 hours>80RaEmergencyLS-01-PL59592800K-6500K595x595mm40W/48W12W-30W1-3 hours>80RaEmergencyLS-01-PL60602800K-6500K600x600mm40W/48W12W-30W1-3 hours>80RaEmergencyLS-01-PL62622800K-6500K620x620mm40W/48W12W-30W1-3 hours>80RaEmergencyLS-01-PL30122800K-6500K295x1195mm40W/48W12W-30W1-3 hours>80RaEmergencyLS-01-PL60122800K-6500K595x1195mm48W/60W12W-30W1-3 hours>80RaEmergencyLS-01-R52800K-6500KΦ180mm10W3W/5W/8W1-3 hours>80RaEmergencyLS-01-R62800K-6500KΦ200mm12W3W/5W/8W1-3 hours>80RaEmergencyLS-01-R82800K-6500KΦ240mm15W3W/5W/8W1-3 hours>80RaEmergen
Features:
LED high lumen output, view-side light;
Warm white, natural white, cool white and other colors can be available;
Color temperature 2800K-3300K, 4000-4500K,5000-5500K, 6000K-6500K;
Input voltage: AC100-240V, constant current;
Dimensions: 5'', 6'', 8'', 595*595mm,600*600mm, 620*620mm, 300*1200mm, 600*1200mm;
Luminous efficacy >100lm/W;
CRI. 80-85Ra;
Working temperature:-15ºC~55ºC;
Beam angle: 120°;
Lifetime: more than 50,000Hours;
Install method: suspended/ceiling mounted/recessed;
Materials: High lumen and quality Epistar 2835 SMD LEDs(22-26lms), 6063 aluminum housing profiles(silver/white);
Adopt own design structure and nice heat sink to keep panel structure steady and high quality;
High-efficiency, low-heat and energy-saving, eco-friendly, long lifetime, UV-resistant,dustproof;
With TUV CE, RoHs approval,TUV/UL driver, 3 years' warranty;
With LED emergency lighting time 1 hour to 3 hours available.
Emergency Lighting Driver Introduction:
Match with DC12V battery (ni-M H), (ni-C d) , which can be high temperature resistant and can be charged.
The device can meet the requirement of 10-100 watts full power LED panel to realize the emergency function;
When emergency lighting is started, the brightness can be 30% -50% of the normal lighting.
It meets international emergency standard, 30% emergency lighting, three-color indicat or lights.
When AC power is working, the inverter makes the battery in the situation of charging or preparing
to work; once earthquak es, fire disasters or explosions happen, the AC power is off, so the inverter
will start the emergency batteries to offer power to lights.
When the battery finishes charging, it will keep the power , compensate the battery' s discharging
and maintain the performance and lifetime of battery.
It can meet 1-5 hour s emergency lighting after match the fitful batteries.
Environment temperature : -20 to 60ºC .
Connect the driver and panel strictly by seeing the connected drawing, do not
advise to take off the cover .
Customer could check the inverter 's power stock per iodically.
Parameters(take 40W emergency panel as sample):
1>. AC 100-240V input , 50/ 60Hz;
2>. DC20-70V Out put;
3>. For LED power : 10-100W
4>. Em ergency time: 3 hrs ( can be custom if possible)
5>. Batter: Dc12V;
6>. Charge current: 100-200m A;
7>. Charge time: 30-45Hrs by slowing charge way;
8>. Max. Size: 440* 75* 75mm.
Emergency Driver Connect Drawing & Attention:
Seeing the connect drawing and each part will separately connect
to the following lines:
1>. "1" connect AC"L".
2>. "2" connect AC"N" and LED driver's AC "-" ends.
3>. From "1" to connect one wire to wall switcher "S",
then connect to "3". LED driver's AC "L" also needsto connect to "3".
4>. "4" connect LED driver's DC"+" of DC output end.
5>. "5"connect Lamp's "-" and LED driver's DC"-" here.
6>. "6"connect lamp's " +" here.
After all connections are finished, then turn on the power to test.
Do not allow the emergency driver to be no load, no matter to check the
lighting function or test the inverter's charging function, it must connect lamp to work.
Main driver wire: AC "L" and "N" must connect to the main wire in the emergency
box, switcher is not allowed to install on them.
When lamp starts emergency lighting, it will be not controlled by Switcher.
Green LED: it shows driver working; Red LED, it shows recharging; Yellow LED:
it shows malfunction.
In the emergency lighting, except LED lamp, all working sign lamps will be turned off.