Business Type:
Manufacturer/Factory
Business Range:
Current Transformer, Voltage Transformer, Combined Transformer, Vacuum Circuit Breaker, ..
Establishment:
1996
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, WesternUnion
Main Markets:
Southeast Asia, Middle East, East Asia(Japan, South Korea), Domestic
OEM/ODM Service
Sample Available

10kv, Casting Resin, Current Transformer manufacturer / supplier in China, offering Single Phase Voltage Transformer for OEM, Indoor Current Transformer Low Voltage Current Transformer, High Quality Low Voltage CT Current Transformer for Switch Gear and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Power Transmission & Transformer Isolation Switch Factory Price High Voltage AC 12kv Outdoor Disconnect Switch

Factory Price High Voltage AC 12kv Outdoor Disconnect Switch

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $100.00/ Piece
Local Area: Wenzhou, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, WesternUnion
Type: High-voltage
Structure: Three-column Disconnector
Installation: Outdoor High-voltage
General
The "(H)GW9-12" outdoor high voltage switch equipment of single phase AC 50Hz.The product is suitable for power system with rated voltage 10kV to make or break power supply under circumstances of with voltage and no load.The isolator is adopts isolated hook rod to operate.Model &Definition
Service conditions
1.The altitude does not exceed 1000m.
2.The ambient air temperature:Maximum:+40ºC;Minimum:-30ºC,Paramos:-40ºC
3.The wind pressure does not exceed 700Pa.(corresponding to 34m/s wind speed).
4.The earthquake intensity does not exceed 8 degrees.
5.The working situation hasn't frequent violent vibration.
6.The installation site of ordinary type isolator should be kept away from gas,smoke chemical deposition,salt-spray fog,dust and other explosive and corrosive maters that affect seriously insulation and conduction capability of the isolator.
7.Pollution-proof type isolator is applying to severe filthy conduction area;however,it shouldn't be any explosive matters and matters causing fire.Technical parametersNo.ItemUnitData1Rated frequencyHz502Rated voltagekV123Rated currentA630(1250)4Rated short-time withstand current and durationkA/s20(25)/45Rated peak withstand currentkA50(63)6Rated short-time power frequency withstand voltageInterphase, to earth(dry)kV/min42/1Interphase, to earth(wet)30/1Break(dry)48/1Break(wet)36/17Rated lightning impulse withstand voltageInterphase, to earthkV75Break858Circuit resistanceμΩ≤809Machanical lifeTimes300010Pollution gradee class11Creepage distancemm≥372Note: If altitude over than 1000m, the rated insulation level should be modify as appropriate.