The homocysteine (HCY) rapid test system
is designed mainly for medium and small scalehospitals, consisting of an HCY assay kit and fluorescence spectrometer OP-162 for the diagnosis of H-type hypertension. The concentration of HCY in blood can be measured precisely and rapidly by this product.
Testing PrinciplesThe plasma Hcy concentrations are measured by enzyme conversion method. Hcy is first reduced by the oxidant and is decomposed by the gene recombinase afterwards. The product react with the chromogenic agent, emitting fluorescent light of 710 nm while being simulated by the light of 660 nm. The plasma Hcy concentrations can be calculated from the fluorescence differentials. Product FeaturesEuropean technoogy & imported raw materias of enzyme reagents; Pre-filled single tube is fast and convenient for individual tests; Lyophiized preparation features high stabiity, and is effective for 16 months;Fluorescence colorimetric method guarantees high sensitivity and specificity; Deliver quantitative results within 10 minutes, making the kit suitable for point-of-care testing ( POCT ); Standard reagent included; Both batch and random testing are available;The 4-point calibration curve guarantees the accuracy of the test results; Wide linear range of 1-100 mol/L & linear correlation coefficient (r)≥0.990; Accuracy: absolute deviation is within ±10 % Precision : repeatability ≤5 %; between-run precision ≤ 5 %; It meets the target requirements of commercial quality control products.
Test Procedures
System Composition
NumberProduct NameSpecificationQuantityRemark1Fluorescence detectorOP-1621Standard2Centrifuge machine80-11Optional3Water bathPointer Type1Optional4Pipette2-20μl1Optional5Pipette20-200μl1Optional6NozzleSupporting Products1000Consumables7Teflon Eppendorf tube shelfMultiple Usage1Optional8Centrifuge tube
(Eppendorf tube)0.5 ml1000Consumables9Timer90min1Optional10Hcy Kitfor 120 people1Consumables
Parameters of Fluorescence Spectrometer OP-162
LightBlue high-brightness LEDOptical ReceiverHighly sensitive silicon photocellExcitation Wavelength650 nmEmission Wavelength710 nmQuantitative Range0-100 μmol/LApplicable Centrifuge Tube0.2 ml, 0.5 mlMinimum Sample Quantity20μl(Centrifuge Tube of 0.2 ml), 25μl(Centrifuge Tube of 0.5 ml)Analysis MethodFluorescence Scattering MethodCurve FittingStraight lineProject Quantity10 projectsSensitivityx0.25-x3.75 (adjustable)Contrast Test Result170 reportsReport Storage1300 reportsDisplayLCD monitor,Resolution of 240x128, Size of 12.7cm(5'')Communication InterfaceRS-232C interfacePrint57mm Mini thermal printerInput Power30 VAFuseΦ5mm x 20mm,T 2 A/250 VAmbient Temperature & Relative Humidity10ºC-30ºC & ≤80%Power SupplyAC 220 V ± 22 V, 50 Hz ± 1 HzDimensions350 mm*285 mm*96 mm (length*width*height)Weigh3 kg