Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Transformers, inductors, electronic transformer for Instrument use. Current Transformer, ..
Establishment:
2005
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Split Core, High Accuracy, Current Transformer manufacturer / supplier in China, offering 1: 3000 Split Core Current Transducer Lo-Sp3010 CT, Round Zero Sequence Current Transformer, Rectance Residual Current Current Sensor and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Sensor Current Sensor High Frequency Current Transformer 1: 50 to 300 10A Input

High Frequency Current Transformer 1: 50 to 300 10A Input

Get Latest Price
Min. Order / Reference FOB Price
100 Pieces US $0.70/ Pieces
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: Electromagnetic
Output Signal Type: Analog Output
Production Process: Encapsulaiton

The LO-GP5600 series of current sense transformers are designed to monitor AC currents. They can be used for
high frequency current sensing, forexample in switched-mode power supplies, motor control and electronic lighting ballasts.
RoHS compliant
50, 100, 200 & 300 Turn variants
Primary current rating 10A
20kHz-200kHz frequency range
Centre tapped variants availableSELECTION GUIDE
Order CodeNumber of
TurnsInductance
Min.DC ResistanceTerminating Resistance to Produce 1VOUT/1AIN±1TurnPins 1&3Pins 1&3, ΩΩLO-56050C504.5mH @1V, 50kHz0.133 - 0.19950LO-56100C10018mH @1V, 50kHz0.93 - 1.40 100LO-56200C20072mH @1V, 10kHz1.87 - 2.81 200LO-56300C300160mH @1V, 10kHz5.73 - 8.59 300LO-56T100C100CT18mH @1V, 50kHz0.93 - 1.40 100LO-56T200C200CT72mH @1V, 10kHz1.87 - 2.81 200LO-56T300C300CT160mH @1V, 10kHz5.73 - 8.59 300ABSOLUTE MAXIMUM RATINGSOperating free air temperature range-40°C to 85°CStorage temperature range-40°C to 100°CSOLDERING INFORMATION1Peak wave solder temperature300˚C for 10 secondsPin finishTin
TECHNICAL NOTES
ISOLATION VOLTAGE
All LO-5600 current sense transformers are tested at 500Vdc for a minimum of 1 second during our standard test procedure.
In addition, as part of our qualification process carried out prior to product launch, the 5600 series demonstrated no isolation breakdown at 10kVdc or 6kVac with a bare conductor as the primary winding. Whilst this does not imply these parts are designed for environments where such high voltages may be present, it does demonstrate the level of isolation voltage these products are able to withstand. Full mains safety isolation can be achieved with appropriately insulated wire on the primary winding.