Current Transformer, Split Core Current Transformer, Split Current Transformer manufacturer / supplier in China, offering Waterproof Outdoor Split Core CT Current Transformer for Power Meter, 500/5A Split Core CT Current Transformer, 2500 AMP Accu CT Split Core Current Transformer 333mv Sensor and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Sensor Voltage Sensor High Quality AC Current and Voltage Transducer

High Quality AC Current and Voltage Transducer

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Chaoyang, Liaoning, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Voltage Type: AC Voltage
Measuring Principle: Electromagnetic Type
Output Signal Type: Analog Type
High Quality AC current and voltage Transducer
Function & Feature
Transforms the measured AC current/voltage to the DC current/voltage output according to the linear scale
Excellent temperature characteristic and good working stability
Configuration compactness and briefnessFUD-Type-Input-Power Supply-OutputTypeI: Single Phase AC Current Transducer
U: Single Phase AC Voltage Transducer
Ir: Single Phase AC Real RMS Current Transducer
Ur: Single Phase AC Real RMS Voltage TransducerAC InputA1: 0~1A, A2: 0~5A, A3: 0~10A.
V0: 0~70V, V1: 0~120V, V2: 0~250V,
V3: 0~300V, V4: 0~450V, V5: 0~500V.Power SupplyP1: AC110V±10%, P2: AC220V±15%,
P3: AC110V~330V.DC OutputO1: 0~5V, O2: 1~5V, O3: 0~20mA,
O4: 4~20mA, O5: RS485.Example 1: FUD-I-A2-P2-O4FUD Series Single Phase AC Current TransducerInput: AC0~5APower Supply: AC220V±15%Output: DC4~20mAExample 2: FUD-Ur-V3-P2-O4Details: FUD Series Single Phase AC Real RMS Voltage TransducerInput: AC 0~300VPower Supply: AC220V±15%Output: DC4~20mAPlease check the Type, Input range, Output range and Power supply at your order.
Technical Index
StandardGB/T 13850-1998, IEC688:1992Accuracy0.2%, 0.5%Consumption≤3VAAccutacy driftAnnual Variation < 0.2%Insulation VoltageAC 2kV/min.1mA (Between Input ~ Output / Power)Insulation Resistance≥20MΩ (DC500V)Surge voltage5KV (Peak Value), 1.2/50μsResponse Time≤350msInput RangeAC 0~10A ,AC 0~500V(Optional), 50/60HzAbsorbed Power<0.5VA/450V, <0.2VA/100V, <0.1VA/5AOverloadCurrent: 2 times continuous,30 times /1s .Voltage: 2 times continuousLoad ResistanceCurrent output: RL≤550Ω
Voltage output: RL≥2kΩWorking environmentTemperature: -10~50
RH: 20~90%, Without condensationStorage conditionsTemperature: -40~70
RH: 20~95%, Without condensationInstallation35mm DIN Sliding-way or M4 screwsDimension55mmx75mmx120mm