Current Transformer, Split Core Current Transformer, Split Current Transformer manufacturer / supplier in China, offering Waterproof Outdoor Split Core CT Current Transformer for Power Meter, 500/5A Split Core CT Current Transformer, 2500 AMP Accu CT Split Core Current Transformer 333mv Sensor and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Sensor Voltage Sensor High Voltage Epoxy Resin Cast Zero Sequence Current Transformer Split Core Type for Protection Devic

High Voltage Epoxy Resin Cast Zero Sequence Current Transformer Split Core Type for Protection Devic

Get Latest Price
Min. Order / Reference FOB Price
3 Piece US $689.00/ Piece
Local Area: Chaoyang, Liaoning, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Voltage Type: AC Voltage
Measuring Principle: Electromagnetic Type
Output Signal Type: Digital Type
Detailed Product DescriptionName:Zero Sequence Current TransformerMaterial:New MagneticUsage:Protection Current TransformerApplication:Protection Device Of Current MeasurementColor:Red And BlackRatio:100-2000A/5A Or 1ALoad:2.5VA-20VADiameter:120mm, 140mm, 160mmClass:5P10, 10P10Weight:7KG-10KG
Theory
Current transformers typically consist of a silicon steel ring core wound with many turns of copper wire as shown in the illustration to the right. The conductor carrying the primary current is passed through the ring. The CT's primary, therefore, consists of a single 'turn'. The primary 'winding' may be a permanent part of the current transformer, i.e. a heavy copper bar to carry current through the core. Window-type current transformers (aka zero sequence current transformers, or ZSCT) are also common, which can have circuit cables run through the middle of an opening in the core to provide a single-turn primary winding. To assist accuracy, the primary conductor should be centered in the aperture.
Applications
LZCK2500-10 zero sequence current transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system. It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes. The current transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings
zero sequence current transformer is mainly measurement current for Protection device
Features
New magnetic material is taken to be the core of the current transformer, which has high magnetic permeability, low saturation magnetization and good stability. Therefore, the measuring accuracy is higher and the instrument security factor is lower. Since the high quality silicon processed by advanced technology is taken to be the core of the protection windings, which assured the accuracy limit factor is higher.
The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance.Small size, light weight, small footprint, fixed in the ring network switchgear cable.The cable can cross the current transformer through its internal poles quickly and uniformly.
The Cast Resin Straight-Through Current Transformer can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding to each model parameter tables.
PARAMETERSTechnical parameters StandardsIEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006Rated primary current100-2000ARated load≤20VARated frequency50Hz or 60HzRated secondary current5A or 1ARated short-time thermal current40kA, 1SRated continuous thermal current120%I1nSecondary winding power-frequency voltage3kV, 1minInstrument security factorFS≤10Mechanical parameters Dimensions (WxDxH) (mm)φ120xφ185x100Weight (kg)7Operating conditions Operating temperature-35°C to +55°CDaily average temp<+40°CStorage temperature-40°C to +70°CAltitude<3500 metersConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.SELECTION GUIDETypeLZCK2500-10LZCK2500-10PurposeMeasuring current transformerProtection current transformerRatioAccuracy class and rated load(VA)Accuracy class and rated load(VA)I1/I20.51310P1510P1010P5300/55552.557.5400/55552.557.5500/557.57.557.510600/557.57.557.510800/5101010510151000/5101515510151200/51520201015201500/5152020101520SELECTION GUIDEModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proofLZCK-55100-1500A≤10VAφ55180x138x522ABS+ResinIP65LMCK185-10300-3000A≤25VAφ185350x283x554.5ABS+ResinIP65LZCK310-10300-600A≤10VAφ50φ50 x φ110 x 321Resinsilicon case (option)LZCK322-1030-600A≤10VAφ50φ50 x φ110 x 521.6Resinsilicon case (option)LZCK350-1020-600A≤25VAφ50φ50 x φ110 x 1053.1Resinsilicon case (option)LZCK720-1020-1000A≤25VAφ60φ80 x φ110 x 502.1Resinsilicon case (option)LZCK2500-10500-1500A≤20VAφ120φ120 x φ185 x 1007Resinsilicon case (option)LZCG530-1030-600A≤20VAφ45φ45 x φ120 x 652.1Resinsilicon case (option)LZCG930-10100-1500A≤25VAφ60φ60 x φ155 x 603.6Resinsilicon case (option)LZCT722-1020-600A≤10VAφ82φ82 x φ130 x 552.3Resinsilicon case (option)