Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Temperature controller, Temperature sensor, Thermometer, Temperature indicator, Timer etc
Establishment:
2000
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Africa
OEM/ODM Service
Sample Available

Temperature Controller, Temperature Meter, Temperature Regulator manufacturer / supplier in China, offering Industrial Automation Digital Temperature Controller with Alarm (XMTF-918), Cj Temperature Meter Temperature Controller (XMTB-608), Digital Temperature Controller with Time Control Function (XMTA-918T) and so on.

1
    YRS
General Supplier
Supplier Homepage Construction & Decoration Building Heater Industrial Automation Digital Temperature Controller with Alarm (XMTF-918)

Industrial Automation Digital Temperature Controller with Alarm (XMTF-918)

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $25.80/ Piece
Local Area: Ningbo, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Certification: UL, Ce, RoHS, ISO, UL
Size: 96*48
Control Type: Digital
SpecificationsXMT-908 intelligence-ability temperature controller is a kind of high performance & reliability intelligence-ability temperature control meter, they are widely used in the automatic control system of the temperature, chemical, ceramics, light, metal, petrochemical and heat treatment industryMain technical specification
1. Measurement deviation: ≤ ± 0.5%F. S± 1
2. Cold end compensating deviation: ≤ ± 2.0C
3. Sampling cycle: 0.5S
4. Control cycle: Relay output 2120S, other is 2S.
5. Relay output contact capacity: AC250V/7A (resistance load) or AC250V/0.3A (perceptual
Load)
6. Driving controllable pulse output: ≥ 3V scope, ≥ 40us width's over zero or trigger contact pulse
7. Driving solid relay signal output: Driving electric current≥ 15mA, voltage≥ 9V.
8. Continuous PID: 010mA (load 500± 200Ω ), 420mA (load 250± 100Ω ), or 05V (load≥ 100kΩ ), 15V (load≥ 100kΩ )
9. Exterior and hole size: 96x 48x 110 92x 44
10. Power: AC85V242V, 50/60Hz
11. Working condition: Temperature 0-50.0C, relative humidity≤ 85%RH, without corrode and strong electric radiation.MeaningofthemodelcodeXMT _ - 9 _ 8 __
(1) (2) (3) (4) (5)
(1)The surface dimension(mm):
Blank:160x80x120 Installation hole 152x76;
A:96x96x110 Installation hole 92x92;
D:72x72x110 Installation hole 68x68;
E: 48x96x110 Installation hole 44x92;
F:96x48x110 Installation hole 92x44;
S:80x160x120 Installation hole 76x156
G:48x48x110 Installation hole 44x44(2)Control Mode: '9':4-key gentle push-switch setting,double row 4-LED digital display,PID and ON/OFF(P=0)control can select.
(3)Additional alarm:'0':no alarm ; '1':one group alarm; '3':two group alarms '5':voice alarm
(4)Signal input type:'8':freely exchange signal(5)Suffix:
Main control output method:
'Blank':relay's open and closed contact output;
'A':Single-phase over-zero spark pulse;
'A3':Three-phase over-zero spark pulse;
'B':Single-phase shift-phase spark pulse;
'B3':Three-phase shift-phase spark pulse;
'C':0~10mA or 4~20mA constant electric current output
'G':ON/OFF solid state relay(SSR)adjustment output;
Auxiliary ways:
'K':with RS485 or RS232 communication module interface;
'Wt':with micro-printer output signal;Connection Method
Code setting modeSeriesCodeNameSetting rangeManualEx-Factory0SPSetting value of temperatureDetermined by P-SL P-SHControl output corresponds to indicator light "OUT".
Please refer to "5.2,The SP setting"501AL1Alarm 1Determined by P-SL,P-SH when the upper and lower limit alarm, it is0~50.0 when the positive deviation alarm and negative deviation alarm
Please refer to ALP1
Corresponds to indicator light"ALM1"3002AL2
()Alarm 2Please refer to ALP2
Corresponds to "ALM2" indicator light1003PProportion modulus0~200When the P↑,the proportion and differential
function↓;If the P↓,the proportion and
differential function↑
When P=0,the meter is under ON/OFF control154ICalculus time0~2000S2405dDifferential time0~200S306AtSetting itselfON/OFFON:open function of setting inself
OFF:close function of setting itselfOFF7tControl period2~120SThis function is no meaning under "ON/OFF". It is preseted 20s in factory.208HyMain control by
drop in level0.1~50.0only have meaning when main control output is ON/OFF(P=0)1.09Hy1drop in level of
AL10.1~50.0It is used as setting of drop in level
for AL1 relay output 1.010Hy2
()drop in level of
AL2
0.1~50.0It is used as setting of drop in level
for AL2 relay output1.011PbSensor error amendment±20.0The sensor have deviation can use item to revisal012FILTFilt modulus0~50Is the software filter constants of measurement sampling.The constant ↑,the measurements antijamming capability measurements antijamming capability↑, but the measurement and system time ↓2013dpDisplay precision0~11: have radix point,0: have not radix point014P-SHThe max.value of temperature range-They are used to reset proper temperature range as per user'application.
As for the Max. temperature range for
different inputs, please refer to Sn,
P-SH≥P-SL40015P-SLThe min.value of temperature range-016OUTL
()The min. value
Of allowable output 0~OUTHCan achieve low and high output limiter. Meaningless when manual and ON/OFF control017OUTH
()The max. value
Of allowable outputOUTL~20020018ALP1AL1 and its output definition0~4'o':indicate no alarm
'1':upper limit alarm
'2':lower limit alarm
'3': positive deviation alarm
'4': negative deviation alarm119ALP2()AL2 and its output definition0~4020COOLSystem function choice0~1'0':reverse control(heat)
'1':positive control(cool)021OPPO()Open power output0~100Soft start function that meters coefficient after first output of electric power022LOCKCode lock0~50LOCK=0,all the parameter can be revised
LOCK=1,only the SP can be revised
LOCK>1,all the parameter can not be revised023SnInput typeCU50()
PT100()
PT100()
K(),E(),J()
T(),S()Input type Max. temperature range
CU50 -50.0~150.0ºC
PT1 -200.0~200.0ºC
PT2 -200.0~600.0ºC
K -30.0~1300ºC
E -30.0~700.0ºC
J -30.0~900.0ºC
T -200.0~400.0ºC
S -30.0~1600ºC24OP-A
()Output type
RLP()
SSR()
Zero()
Mut()
0~10MA()
4~20MA()RLP Relay output
SSR Solid state relay
Zero Zero passed trigger of controlled silicon
Mut Controlled silicon phase-shifted trigger
0~10MA linearity current control output
4~20MA linearity current control outputRLPCertificate
Packaging Detailed