Industrial Water Cooled and Air Cooled Air Freezer Cooling ChillerWe have these products:
3kw ~3000kw/Outlet temperature:7ºC~ -85ºC/
Air cooled,water cooled,screw type,scroll type,heat pump chiller, modular chiller.
The Details of the chiller:1.The Temperature Range:7ºC to -85ºC.
2.Cooling Capacity Range:
1RT to 1000RT
3.52kw to 3520kw
12010Btu to 12010240Btu
3027.2Kal to 3027200Kal
3. The Refrigerant:R22/R407c/R410a/R404a/R134a/R507c.
4.We have many typeswater chiller and we can also produce the chiller
according to your requirements.One Parameter of our water chiller:ModelUNITWD-3WC/SM15WC/SM18WC/SM110WC/SM112WC/SM115WC/SM120WC/SM125WC/SM130WC/SM140WC/SM1Cooling capacityBtu214963446162098689227915899972133750157976198237269548RT1.82.95.25.86.68.311.113.216.522.4Kw6.310.118.220.223.229.339.246.358.179x10³Kcal/h5.48.715.717.42025.233.739.85068Total PowerKW2.303.605.806.607.5010.1013.7014.5020.1026.80Total CurrentA4.006.4010.2011.7013.3017.9024.4025.8035.8047.70CompressorQtyset1.001.001.001.001.001.001.002.002.002.00Input powerkw1.903.205.205.806.709.3012.6013.4018.6025.30Operation CurrentA3.405.709.3010.3011.9016.6022.4023.9033.1045.00CondenserTypeHigh efficiency copper dry type shell-and-tube heat exchangerCooling Water FlowL/min2642748294121163188241326Water Pipe connectionmm20202532323240405065EvaporatorTypeHorizontal shell-and-tube/Coil type high efficiency copper heat exchanger Freezing water FlowL/min182952586684112132166224Waterpipe connectionmm20202532323240405065Freezing Water PumpTypeHigh efficiency,low noise InputPowerkw0.371 0.550.750.750.751.11.11.51.5Headm15201919172524242220RefrigerantType
R22/R134A/R407C/R410A/R507/R404Water tank Indicating VolumeLiter8090190190190210250250320400Safety protectionhigh and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc.Dimensions (L*W*H)Lengthmm1150115013501350135016001900190021502300Widthmm75075085085085090090090010001100Highmm90090012001200120012001200120012001300Total WeightKG150220.310360.450.650.850.1050.1250.1350.
Note:
1, the table refrigeration conditions: freezing glycol water inlet temperature 0 ºC, water temperature -5ºC, the cooling water temperature 30 ºC, water temperature 35 ºC;
2, this series of units used in low temperature conditions, to use 25% of the glycol for antifreeze coolants;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa);
6, In addition to the specifications and requirements, we can provide non-standard products according to customer requirements.