MC-series Mini Intelligent In petroleum and chemical industry, pneumatic actuator is a conventional choice; However, with further development of science and technology, the electric actuator has gradually enter into the market depending on its safe and reliable, economical and practical features, which becomes the developing direction of the new era.
MC-series electric actuator is used to replace the conventional pneumatic actuator, and it is a new dual power supply product designed for the petrochemical industry.
Standard Functions:
Prominent comparative advantages and functional features
01Non-intrusivedesign:Itcanset,browseandcontrolparametersviamagneticbuttononoperationpanelorinfrared
remotecontrollerwithoutopeningthemachinecover.02Richdisplayfunction:Allthemenus--input/output,variousalarmandfaultinformation,etc.,aredisplayedinEnglish
andChineseclearlyinsteadofpatternsandcode,andbetransferredfreely.03Mechanicaltransmission:Withdifferentialplanetarygeartransmission,ithashugeloadingandimpact-resistance
capability;mechanicallifetimeissuperiortothatofwormandgearorspurgearstructure.04Variablespeed:Forvalve'sworkingspecialty,speediscontrolledin3-section:Differentspeedsaresetinvalve
opening/closingmoment&strokeinterval,wellsolvingvalveprotection,largetorquereleaseandvalveshut.05Variabletorque:Outputtorqueisadjustedbysettingmotorspeed;theautomaticjudgingandmodifyingshut.1-4level
overtorqueprotectionvaluewellremediestypeselectionerrors.Maxadjustingrangeis≤2timesofstandardtorque.05Avoidingwaterhammerandcavitationerosion:Fullstrokespeediscontrolledin3stagesrespectively
(openingvalve-strokerange-closingvalve);dynamicchangesofactuator'sworkingstrokerangecomplieswiththe
characteristiccurvechangesofvalveflow.07Simpleandreliableelectronicstrokelimit:Afterdrivingvalvetofullyclosed/openpositionelectricallyormanually,
press"/confirm/i"key,thevalveopeningandclosingendpointshavebeen/confirm/ied.08Auto-recoveryofcrashbystronginterference:Whenactuatorcrashesduetostrong&complexsignalinterference,
controlsystemquicklyjudgesandautomaticallyrestorestheoriginalrunningstatebeforecrashwithin200ms.09Freelocal/remotetransfer:Themechanicaldesignwithoutclutchenableshandwheelrotationeveninrunningstate.10Auto-identifysignalfault,overcurrent/temperature&phasesequence,protectphasedefault.11Torquestatus:Timedisplaying,recording,browsingandalarm12Precisefrictionlesselectronicbraketechnology:Whentheactuatorreceivespositioninstructionsof"open/close/stop"
issuedbytheDCS,CPUcontrolunitstartscomplexcalculationsinPID,andrepeatedlycomparespositionandspeed;
whenspeeddecreasesto0,valvepositionisaccuratelymovedtothedestination.13Useelectronicreversingtechnique,withoutlimitofstartingfrequency.14Jammingrelease:Ifvalvegetsblocked,controlsystemautomaticallytries3round tripimpactswithintorqueprotection
value;jammingreleasing,actuatoroperatesnormally;otherwise,alarmsignalisissued.15Modulardesign:Separategearbox,displaycavity,controlcavity,andwiring16ESDfunction(EmergencyShutdownfunction)17Fieldbus:Thedesignideaofstandardizedanalogquantity/switchquantitycoexistence,modularpluggabledesign
ofHART,ProFbus,Modbus.18SupportofPDAfunction(Optionalfeatures):1)Infraredbluetoothautomaticsearchandcode-matchingofsitenumber.2)Inspect29kindsofworkingstatusofactuatorconstantly.3)Accesstotheelectronicarchivesofactuatorsatanytime.4)Theactuatorsavesworkingstatusanddatainintervalsof20s,forlaterdownloadandread.Energy-saving&environmentprotection:ComparedwithACmotor,itcansaveenergyby4
TechnicalParametersofStandardConfigurationPowersupply24VDC
230VACProtectionlevelIP68Torqueinspection
precision2%LCD4linesInput/outputSelectiontableAlarmrelay3-6Ambient
tempreture-25-85ºC
-40-60ºCCommunicationprotocolHART
ProFBus
motBUsOvertorqueprotection2classAmbienthumidity100%RHPositionfeedbackpotentiometerOver
temperatureprotection130ºCSpeedadjustingrange15-100%Positionprecision±0.1-0.3%StrokelimitprotectionElectronicTorqueadjustingrange10-100%Responding200msShockresistance600Hz3-axis
10gLoadfactor(t/h)S570%,max
4000times/htime10mSupportPDAremotecontrolOptical
MotorParametersMotortypesDCbrushless
variablespeedProtectionlevelsIP68Power(KW)0.01-0.1StructuralformsSpecialdesignMotorrotation
rate4000rpm
(variable)Housingmaterials63M-160L
castalluminumInsolationlevelHclassCoolingmethodsSurfaceaircoolingSaturationtemperature
ofmotorabout60ºCMomentofinertia60g.cm2
D+R MC SeriesPermanent Magnet DC Brushless Speed Regulating Eelectric Actuator.[Dual power supply]Selection Table (Part-turn)No.Standard TorqueType1-ON-OFF1-Whole installationPower supplyCommunication protocolOutputInputSpherical Angle chain/Stents(Nm)2-Adjust1-400VAC0-without1-4-20mA1-4-20mA3-ON-OFF +Adjust2-Separate installation2-230VAC1-ProfBUS2-0-20mA2-0-20mA3-24VAC2-ModBUS3-on-off3-on-offx4-24VDC3-HART4-on-off
+4-20mA4-on-off
+4-20mA/G-Need150DR-MCP0.5-2100DR-MCP1-3200DR-MCP2-4300DR-MCP3-5600DR-MCP6-61000DR-MCP10-71200DR-MCP12-81600DR-MCP16-92000DR-MCP20Instructions
Explosion-proof type : DR-Ex1MCP6-214011 Ex1-Ex dII B T4;Ex2-Ex dII B T6;Ex3-Ex dII CT4;Ex4-Ex dII CT6;
We are manufacturers,Accept special product customization anddesign.
[Dual power supply]Selection Table (Linear)No.Standard TorqueType1-ON-OFF1-Whole installationPower supplyCommunication protocolOutputInputSpherical Angle chain/Stents(KN)2-Adjust1-400VAC0-without1-4-20mA1-4-20mA3-ON-OFF +Adjust2-Separate installation2-230VAC1-ProfBUS2-0-20mA2-0-20mA3-24VAC2-ModBUS3-on-off3-on-offx4-24VDC3-HART4-on-off
+4-20mA4-on-off
+4-20mA/G-Need1225DR-MCP1-38DR-MCP2-410DR-MCP3-512DR-MCP6-616DR-MCP10-720DR-MCP12-825DR-MCP16-Instructions
Explosion-proof type : DR-MCT12-214011 Ex1-Ex dII B T4;Ex2-Ex dII B T6;Ex3-Ex dII CT4;Ex4-Ex dII CT6;
We are manufacturers,Accept special product customization anddesign.