Business Type:
Trading Company
Business Range:
Ultrasound Machine, Doppler Ultrasound, Autoclave, Dental Chair, Operation Room Equipment, ..
Establishment:
2011
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
South America, Europe, Africa
OEM/ODM Service
Sample Available

Manual Hospital Bed, One Crank Hospital Bed, Medical Bed manufacturer / supplier in China, offering Medical One Crank Manual Hospital Bed with ABS Headboards, Double Head Ceiling Surgical Room LED Bulbs Shadowless Medical Light, Medical Equipment LED Shadowless Surgical Lamp/Theatre Light for Operating Room Lights and so on.

1
    YRS
General Supplier
Supplier Homepage Furniture Outdoor Furniture Medical Equipments Mobile Energy Recovery ICU Anesthesia Ventilator Machine

Medical Equipments Mobile Energy Recovery ICU Anesthesia Ventilator Machine

Get Latest Price
Min. Order / Reference FOB Price
1 Unit US $4999.00/ Unit
Local Area: Guangzhou, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Brand: Mecan
Place of Origin: Guangdong, China
Instrument classification: Class II
Product name: ICU Mobile Ventilator
Medical Equipments Mobile Energy Recovery ICU Anesthesia Ventilator Machine

Model:MCB-PA-700B

How does our ICU ventilator work?

The MCB-PA-700B ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.

What is the detail of our mobie ventilator?

Display: 10.4''LCD Display Following Parameters & Real time waveform display

1.Operating mode and respiratory rate;

2.Ventilator control frequency set by medical staff;

3.Tidal volume of each breath in the patient;

4.Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;

5.Expiratory phase and inspiratory phase and actual respiratory rate;

6.Minute volume;

7.Setting and adjustment of inspiration triggering pressure, PEEP, and highest airway pressure;

8.Real-time variation in internal airway pressure.

Ventilator Construction

1.Environmental Protection Material construction, hardly to be broken.

2.Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions.

Air Compressor

1.Power: AC220V + 22 v, 50 Hz + 1 Hz and 300 va has a good reserve of single-phase ac power supply

2.FUSE :Φ 5 x 20 / F8A

3.Output gas pressure: 0.3 ~ 0.4 MPa

4.Output gas minimum flow: ≥50L/Min

5.Output gas transient flow: ≥100L/Min

What is the technical data of our medical ventilator? Physical specifications Display10.4'' LCD DisplayModepneumatically powered and electrically controlled systemTrolleyFitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisionsTechnical SpecificationsGas requirementMedical oxygen and nitrous oxide with a pressure ranging from 280~600kpasafety valve <12.5 kPaRespiratory Rate1 ~ 99 bpmOxygen Concentration21% ~ 100% Maximum Minute ventilation≥18L / minmodes of ventilationA/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONTVentilator compliance≤30 Ml/kPaPEEP0 ~ 1.0 kPaPtr-10 ~ 10 hPaIMV frequency1~20 bpmI/E Ratio4:1~1:4, Has the inverse ratio ventilationTidal VolumeSetting Range: 50~1500MLDisplay Range: 0~2000ml ; resolution ratio: 10mlInspiratory Plateau0~1sMaximum Safety Pressure≤ 6.0kPaSighone deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting pointPressure limit range1.0~ 6.0kPaAirway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.1 kPa ~ 6.0 kPa;Upper: 0 ~ 5.0 kPa±0.2 kPaVentilation Volume alarm: ≥ 18L/ MIN Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120sThe airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.Operating conditionsAmbient temperature: 10 ~ 40oCRelative humidity:no higher than 80 %Atmospheric pressure:860 hPa ~ 1060 hPaPower requirement: 100-120 Vac, 50/60 Hz; Attention: the AC power supply used for the anesthesia machine must be wellgrounded.Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. StorageAmbient temperature-15oC ~ +50oCRelative humidityno higher than 95 %Atmospheric pressure86 kPa ~ 106 kPa. It should be stored in a room without corrosive gas and well ventilatedPackagepackaging boxcomply with the requirement of GB/T 15464 Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation Moisture protection and rain protection to ensure that product is protected from natural damage. Safty & AlarmGas source pressureImmediate alarm; “high level alarm” indicator flickers raising an audible alarm.Airway Pressure AlarmThe airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm. Tidal Volume AlarmLower than 50ml, The alarm will be raised after one breathing cycle. Ventilation Volume AlarmLower: 0~12L/Min;Up: 18L/ MinBattery Voltage AlarmIt alrms when the battery voltage is lower than 10.5V.Power On Self TestSelf test before working, assure it's working normally.

More Products

Why choose us ?

How to contact us ?

Click to contact us now !!!