Face Mask, Mask, Protect Mask manufacturer / supplier in China, offering 3mm Thick Acrylic Material or PC Material Protect Face Mask Mslptm01, Medical Ce Certified 15 Inch Display Ultrasound Machine Mslpu75, Mslpu76 Portable Ultrasound Black and White Ultrasound Machine with Good Quality and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Set | US $1145.00/ Set |
Local Area: | Guangzhou, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, D/P, PayPal, WesternUnion, MoneyGram |
Brand: | MSL |
---|---|
Model Number: | MSLC05 |
Place of Origin: | Guangdong, China |
Instrument classification: | Class II |
Introduction
The Introduction of Non-invasive Ventilator
The BiPAP is bi-level continuous positive airway pressure device that mainly
used for home care and clinical treatment of obstructive sleep apnea-hypopnea
syndrome (OSAHS) or respiratory insufficiency.
The Device can be set respectively the IPAP (inspiratory positive airway pressure) and the EPAP (expiratory positive airway pressure).It performs the therapy through the corresponding airway pressure set by professionals according to different degrees of users’ apnea when in use and it runs continuously.
The humidifier cooperates with the host to provide the user with a air of suitable temperature and humidity to avoid drying of user’s nasal mucosa and make comfort treatment. The host controls the humidifier’s turning on/off, the principle of which is to heat the water in the chamber and make the air inhaled by the user with suitable temperature and humidity.
Please contact Niki for more details.
Feature
The Feature of Non-invasive Ventilator
Buttons
1. ON/OFF button: It may turn on or off the device and close alarms. If the device is connected to the power, the ON/OFF button indicator will be on.
2. Shuttle flying: It can be rotated clockwise/counterclockwise or be pressed. When it is rotated clockwise, it may move to the next settings on the current interface or enlarge the parameter or come to the next parameter. When it is rotated counterclockwise, it may move to the previous focus on the current interface or diminish the parameter or come to the previous parameter. Press the shuttle flying, it may perform the functions indicated by the current focus, or enter / edit the interface//confirm/i.
Display Screen
A LCD display screen is adopted to mainly display the current parameters and
states for the user and operator. Please refer to Chapter 3 Device Operation for more
interface operation.
Power Adapter, Power Port, Data Port, USB Port and USB Cable
1. The power adapter is mainly to transfer the external power supply into the voltage and current required for the device operation.
2. The data port is mainly for software updating and maintenance by the manufacturer.
3. USB port and cable. The operator may connect the device via a USB cable to get the data of the user.
Humidifier
The humidifier is to provide users with comfort airflow by heating the water in
the water room. Please turn off the humidifier when you need not it. Better use the
recommended accessories by manufacturer otherwise it may cause air leakage.
Power Outage Alarm
During the running state, the exhaled air may be re-inhaled by the user in case of
any power outage happens. To avoid this phenomenon, when power outage happened
the system will provide a buzzing alarm and it will last for 30 seconds. During the
alarm, press the ON/OFF button, or connect the device with power again, the alarm
will stop. After connect the device with power, the system will enter into the normal
working state.
Technical Datas
Environmental Specifications
Working Environment
Storage Environment
Temperature
5℃ to 35℃
-20℃ to 60℃
Humidity
15% to 95% (no condensation)
15% to 95% (no condensation)
Atmosphere pressure
77 to 101kPa
Inapplicable
Physical Specification
Dimension
255mm*170mm*112mm
Weight
1.8Kg
Water capacity
MAX 200ml
Parameter Scope
Pressure
4~ 20cmH2O (±1cmH2O) with a 0.5cmH2O increment
IPAP
4~ 20cmH2O (±1cmH2O) with a 0.5cmH2O incrementEPAP
4~ 20cmH2O (±1cmH2O) with a 0.5cmH2O incrementISlop
1-6 level
Esens
1-6 level
BPM
4-40BPM
InspTime
0.5-3.0s
Ramp
0-60 min
EPR
0 level Close EPR
1 level setting pressure -2cmH2O
2 level setting pressure -3cmH2O
3 level setting pressure -4cmH2O
Humidifier0 gear close the humidifier
1 level 45℃
2 level 50℃
3 level 55℃
4 level 60℃
5 level 65℃
System time
24-hour
Main Picture
The Main Picture of Non-invasive Ventilator
Certificates
Please contact Niki if you want to purchase it.