Features:1. Sine-wave output:
True sine-wave output with less than 3% THD.2. Double Conversion Design:
Zero transfer/ complete isolation of input AC.3. UPS Monitoring Software:
Powerful true RS232 communication via the enclosed software
To manage and safely shutdown operating systems.4. Network RJ45/11 protection:
Complete powerful network and phone line surge protection.5. AC Surge Suppressor:
Powerful multi-stage surge components that exceed IEEE requirements.6. SNMP Slot Option:
Allows for remote monitoring and control via.7. Sleep Mode:
Worry free battery management. The unit turns itself off after ten seconds to conserve battery
Power when no power needs are detected.8. Battery level indicators:
LED''s indicate battery levels.9. Load Sensing:
The incorporated LED load indicators allow IT professionals to manage backup time and balance power loads.10. Low Battery indicators:
The low battery level indicator will warn of eminent UPS shutdown two full minutes before unit shuts down.11. Replace Battery indicators:
A preventative measure that indicates when batteries must be replaced to prevent server crashes.body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}
body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}Model
C1KS
C2KS
C3KS
Rated Power
VA/W
1kVA / 0.7kW
2kVA / 1.4kW
3kVA / 2.1kW
Input
Nominal Voltage
220VAC
Voltage Range
115 ~ 300VAC
Frequency Range
46 ~ 54Hz(default), user adjustable within 40~60Hz
Power Factor
0.97
Connection
IEC320 -10A inlet
IEC320 -16A inlet
Output
Voltage
220VAC ± 2%
Frequency
46~54Hz or 50Hz ± 0.2Hz (Line mode)
50Hz ± 0.2Hz ( Battery mode)
Waveform
Pure Sine Wave
Distortion
3%
4%
Overload Capability
108% ~ 150% for 30 sec., ³150% for 300 ms
Current Crest Ratio
3:1
Connections
IEC320 -10A *4
IEC320 -10A *6
IEC320 -10A *3 and
Terminal Block
BatteryType
Sealed, Maintenance free, Lead-Acid
Nominal DC Voltage
36VDC
96VDC
Back-up Time
Depends on the capacity of the external battery bank
Connection
External Battery Socket
BypassAutomatic Transfer
On overload and UPS failure
Before UPS Power-on
Default "NO", user adjustable to "YES"
Voltage Range
80 ~ 264VAC (Default), user adjustable within 80 ~ 286VAC
Transfer Time
0 ms; less than 4 ms from inverter to bypass and vice versa
LED Indicators
Status
Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault
Audible Alarm
Bypass, On battery mode, Battery low, Overload, Fault
Acoustic Noise
At 1 meter distance
45 dBA
50 dBA
Communications
DB-9 Port
RS-232 Serial Interface
Intelligent Slot
Options: WebPower, AS400 Card or WinPower CMC
Network Surge Protection
RJ45 I/O port available for 10 base-T network or Fax/Modem
Environmental
Operating Temperature
0 ~ 40°C
Operating Humidity
20 ~ 90% non-condensing
Weight
Net (Kg)
7
13.5
14
Dimensions
W x D x H (mm)
145 x 400 x 220
192 x 460 x 348