Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Rru Station, UPS, Rru Power manufacturer / supplier in China, offering Outdoor Online Natural Cooling UPS 4G Rru Power, 25GB/S SFP28 Transceiver, C-Band 100GHz Athermal AWG DWDM Module and so on.

1
    YRS
General Supplier

Outdoor Online Natural Cooling UPS 4G Rru Power

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $100.00/ Piece
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Phase: Three Phase
Type: Standby
Protection: Sealed Maintenance Free
Product Introduction
Product Name: Outdoor online Natural Cooling UPS for 4G RRU station
Product Positioning: To provide an uninterrupted power supply guarantee for 4G RRU station
Application Scenarios: Outdoor derrick, outdoor wall and indoor distribution
Loading Capacity: 500w (three 4G RRU station)
Electricity Time: 4 hoursProduct Features:
The integration of power supply and battery, small volume and high power density.
Realizing the natural cooling through the cooling fin and insulating the inside cabinet from outside. Reaching a protection grade of IP 65 and thus elevating product operational reliability.
Plug and play with simple maintenance.
Easy of derrick installation.
Product Model: OP500A
Product Positioning: only providing power supply guarantee rather than optical fiber distribution and optical transmission device installation site.
Product Superiority: Optical-electric separation, maintenance interface separation and easy of power supply maintenance.Product Model:OP500A-M
Product Positioning: The integration design of Photo electricity, installation of fiber distribution and optical transmission device.
Product Superiority: A high concentration degree.Cabinet Specification ParameterProduct ModelOP500AOP500A-MW*D*H500x300x193mm500x300x225mmDispositioncabinet, power supply, phosphate battery, monitoringcabinet, power supply, phosphate battery, monitoring, ODF, optical modem positioning, optical cable positioningWeightProtection GradeIP65IP65Routing ModeBottom inlet-outlet lineBottom inlet-outlet lineOperating Temperature-20-55c-20-55cStorage Temperature-25-60c-25-60cRelative Humidity0-95% non-condensate0-95% non-condensateOperating Altitude<1500mm, the additional part over 1500mm is used according to regulated GB/T3859.2<1500mm, the additional part over 1500mm is used according to the regulated GB/T3859.2Noise< /=50dB< /=50dB
Power Supply Specification ParameterRated Power500WSwitching Time0msOverall Efficiency93%Operating ModeonlineWarning FunctionOverload, grid abnormal, UPS breakdown, low battery voltageProtection FunctionShort circuit, overload, over-temperature, low battery voltage, input voltageCommunication FunctionRS485AC InputInput Voltage220VacInput Voltage Range90~280VacPhase NumberSingle-phase three -wireInput Frequency Range45~55 HzPower Factor≥0.98AC OutputDC OutputOutput Voltage230±1% VacOutput Voltage53.5VdcOutput Current2.2AOutput Current6AOutput Frequency50±0.2HzOutput Route2(battery + load)WaveformDC OutputPower FactorSine waveOutput Route0.8Rated Power4
Battery Specification ParameterBattery TypeLithium iron phosphate batteryBattery Capacity10Ah,20AhFloat Charge Voltage42.00-53.5VAverage Charge Voltage44.00-57.6VBattery ManagementBattery Oder42.0-43.6VStandard Charge Current0.1CAverage Charge Current0.075CFloat Charge Current0.03CCharging Filter Protection Point0.11CBattery Discharge Current12A
Monitoring functionAdjust output voltageAdjust proportion drift charge voltage through monitoring panel, and give the system output voltage based on the judgment of proportion drift charge voltage condition.Real - Time Status AcquisitionBattery Management1. Battery low voltage: when the output voltage is under the setting low-voltage battery, the monitor gives output warning, and dry contact output warning, then the warning LED light. When the voltage restores, the warning stops. There is some return difference between the voltage restoration and warning point.
2. Battery down voltage: under the battery discharge condition, and when output voltage is lower than the setting once down voltage, the system will disconnect battery, and connect relay and output LED warning. When the voltage restore to the setting down voltage, the relay will be closed.
3. The management of battery proportion drift charge: when the charging current of the battery is beyond its maximum charging current, the system gives the battery constant current equalizing charge. And when the constant current equalizing charge is charged to equalizing charge voltage, the system will gives a constant voltage equalizing charge. When the current of constant voltage equalizing charge is smaller than that of equalizing charge turning to floating charge, the current is under a floating charge. And, when floating charge current is larger than that of floating charge turning to equalizing charge, the system gives a equalizing charge. Floating charge continues to the setting time, it will turn to equalizing charge automatically. When the time of constant voltage equalizing charge is beyond the lasting time of the setting equalizing charge, is will turn to floating charge, and the manual equalizing charge turns to equalizing charge.This UPS possesses a stronger detection and control function. With the host computer control, it can detect the working condition of the modules in real time. According to the detecting parameter, it can control the modules working condition, meet the maintenance and management demand of battery pack, and thus making the system work safely and reliably. Through RS485, it can communicate with the host computer, and receive the inquiry, parameter setting and control from it. Then the parameter will be sent to the host computer for centralized management.1. It can read and set the battery proportion drift charge voltage and battery charging current limiting point.
2. It can read 48V output voltage, current, and inverter output voltage and current.
3. It can read the warning messages of UPS like the malfunction of AC input, low voltage, 48Vshort circuits, 48 current limit, inverter short circuit, inverter overflowing and so on.