Medical Freeze Dryer, Food Freeze Dryer, Fruit Freeze Dryer manufacturer / supplier in China, offering Bench-Top Mini Small Laboratory Vacuum Freeze Dryer (Lyophilizer) Drying Machine, Ftir Fourier Transform Infrared Spectrometer (High performance), Automatic Fusion Machine (for X-ray fluorescence spectroscopy) and so on.

1
    YRS
General Supplier

PT-D92-3536 Cleveland Open Cup Flash Point Tester

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Xian, Shaanxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Power Supply: AC (220±10%) V, 50Hz.
Heating Device: Quartz Tube Furnace Heating, Power:0W to 600W
Test Flame Applicator: It Applies The Test Flame Automatically
Summary
PT-D92-3536 Cleveland Open Cup Flash Point Tester is designed and made as per standards GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points - Cleveland Open Cup Method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79°C and below 400°C except fuel oils.Main technical featuresIt adopts special heating furnace to ensure the safety of test. The heating power is continuously adjustable. It can meet requirements of test.The instrument adopts desktop structure. The stainless steel working table and furnace shell make it beautiful and elegant.The instrument is fully self-contained complete. The operator can do determination as long as connecting with coal gas or other civil gas.It equipped with flame extinguishing cover which accord with requirements of test.
Main technical specifications
1. Power supply: AC (220±10%) V, 50Hz.
2. Heating device: Quartz tube furnace heating, no naked fire, explosion prevented. The power is adjustable from 0W to 600W.
3. Test flame applicator: It applies the test flame automatically.
4. Thermometer: (-6 ~ 400)°C. It is the same as thermometer ASTM 11C.
5. Igniting device: (1) Ignition source: coal gas(or civil gas)
(2) Flame diameter is 3.2mm ~ 4.8mm
6. Ambient temperature: (-10∼50)°C
7. Relative humidity: ≤85%
8. Maximum power consumption: 650W
9. Dimension: 350mmx290mmx350mm (thermometer is not included)
Standard AccessoriesNo.ItemUnitQtyRemarks1Oil cupPiece12IgnitionSet13Thermometers (-6~400 ºC, scale division is 2 ºC)Piece14Thermometer supportSet155A fuse(Ф5x20)Piece26Latex pipeΦ6Meter1.5Connecting theinlet portof the instrument7Gas pipe connecting headPiece1Gas pipe and latex tube adapter8Flameout coverPiece1