Engage in amusement equipment industry for more than 20 years, with the ability of independently research and develop products.We have long time Co-operation with many famous companies in Europe, Amer...
Min. Order / Reference FOB Price | |
---|---|
1 Pieces | US $800.00/ Pieces |
Local Area: | Zhongshan, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, D/P, Paypal, Western Union |
Instrument classification: | Class II |
---|---|
Warranty: | NONE |
After-sale Service: | NONE |
Functional level:Double level ST mode
Working mode:CPAP
Adaptive disease:COPD,emphysema,Asthma, pulmonary heart disease,
Central sleep,Bullae of lung(Follow doctor's advice)
Acute and chronic respiratory failure
Warning:
patients who meet the following conditions can only receive continuous positive
airway pressure treatment under the condition of special care and regular monitoring by doctors
1, pneumothorax, mediastinal emphysema
2. Cerebrospinal fluid leakage, traumatic brain injury or intracranial gas
3. Shocks from various causes are not corrected
4. Upper gastrointestinal bleeding without effective control during nosebleed active phase
5. Unconsciousness or unconsciousness cannot cooperate with or receive mask treatment
6, huge vocal cord polyps
Bi-level non-invasive ventilator
Pressure: 4-30 mmHg
Mode: S / T, with target tidal volume function
Inspiratory time: 0.3s-3s
SpO2 monitoring function
Real-time display of pressure flow waveform
Remote data transmission, remote parameter adjustment
Ventilator type
Electric control
Scope of application
Sleep apnea-hypopnea syndrome, severe snoring, and treatment of patients with respiratory insufficiency.
Display interface
3.5-inch LED screen, Chinese operating system
*Ventilation mode
CPAP,S,S/T,T
Pressure range
4-30cmH2O(±0.5cmH2O)
Pressure accuracy
±0.5cmH2O
Delayed boost
0-60min,setting the binning interval 5min
Initial pressure
4cmH2O-treatment pressure / respiratory pressure
Treatment pressure
4-20cmH2O(in CPAP mode)
Target Tidal Volume
150ml - 1500ml , on / off
Maximum suction pressure
4-30cmH2O,(can be set when the target tidal volume function is on)
Minimum suction pressure
4-30cmH2O(not higher than suction pressure),(can be set when the target tidal volume function is on)
Inspiratory pressure
4-30cmH2O
Expiratory gas pressure
4-30cmH2O
Expiratory decompression
Patient, off, 1-3, three adjustable
Manual pressure regulation
0-2level, 0-2cmH2O (only available in CPAP mode)
Inspiratory sensitivity
level 1-8
Expiratory sensitivity
level 1-8
Breathing frequency
3-40 times / minute
Inspiratory time
0.3-3.0s
Backup frequency
on/off ,default value10
Pressure rise time
level 1-4
Humidifier
1-5 total 5 levels adjustable
Auxiliary functions
Automatic leak compensation, automatic startup, automatic shutdown, delayed shutdown, screen backlight adjustment
Monitoring parameters
pressure, tidal volume, respiration rate, minute ventilation, leak volume, inspiration time,
Alarm prompts
Pipes and masks falling off, air leakage prompts, power interruption, treatment machine failure, humidifier failure, low voltage, high breathing rate, low breathing rate, low minute ventilation, replacement of filter cotton, SD card full, Reinsert SD card
SD card data
RESmart Npap data analysis software
SD card
standard
Accessories SD card
standard
Pipe
φ22mm,length is 1.8m
Face Mask
Standard nasal mask
Noise
≤30dB
During use
During transportation and storage
Temperature
5℃-35℃/-20℃-55℃
Atmospheric pressure
760-1060hPa/760-1060hPa
Working time
≥8 hours
AC voltage
100-240V
Frequency
50Hz/60Hz
Input power
≤2A
Waterproof level
IP22-anti-drip equipment
Instrument size
290mmx180mmx134mm
Weight
1.5kg (without humidifier) 2.5kg (with humidifier)