Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Testing Transformer, High Voltage Tester Transformer, Dielectric Strength Tester manufacturer / supplier in China, offering Manufacturers Electrical High Voltage Testing Transformer / AC/DC Withstand Hipot Tester / Dielectric Strength Tester Price, Primary Current Injection Testing Procedure of Circuit Breakers, No Partial Discharge Test System for Transformer and Power Cables / Circuit Breaker and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Electronic Instrument Other Electronic Instruments Portable CT PT Tester Current/ Instrument Transformer Analyzer

Portable CT PT Tester Current/ Instrument Transformer Analyzer

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $6.00/ Piece
Local Area: Wuhan, Hubei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: CT/PT Analyzer
Load Way: Electronic Load
Loading Method: Dynamic Load
Summary:CT PT analyzer is used to measure all kinds of current transformer and voltage transformer. It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test. The tester can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified. Applications:Tests for current transformer:
1) Excitation curve and parameters test
2) Turns ratio test
3) Ratio and phase error test
4) Polarity mark check
5) Winding resistance measurement
6) Secondary loop burden measurement
7) Error line curve test for protection CT
8) Transient CT parameters test
9) CT nameplate guess
10) Saturation hysteresis loop curve measurement
Tests for voltage transformer:
1) Turns ratio test
2) Ratio error and phase angle error test
3) Polarity test
4) Secondary burden test
5) Winding resistance test
Features:1. Make evaluation for test results according to selected standards.
2. Make word report for test result.
3. Make word reports one time for multi-group test records on the PC.
4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
5. Compare excitation curves with saved excitation curves in the same window.
Technical parameter1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply: AC220V±10%,50Hz/60Hz±10%
3 Power output: 0.1~125V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output:300VA
6 Maximum knee voltage measurement; 45kv
7 Current measurement:
Range:0~10A (automatically change range in 0.1/0.4/2/10A)
Error <±0.1%+0.01%FS
8 Voltage measurement:
Range:0~200 V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range :1~30000,
1~1000 error<0.05%
1000~2000 error<0.1%
2000~30000 error<0.2%
10 Phase measurement: error:±2min,resolution:0.01min
11 Coil resistance measurement:
Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.1%RDG+0.01%FS
Maximum resolution:0.1mΩ
12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree
13 CT Secondary burden:
Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution 0.001ohm
14 PT Secondary burden:
Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15 Saved data groups:>1000groups
16 Work condition: Temperature:-10ºC~50ºC, moist:≤90%
17 Size: 485mmx356mmx183mm
18 Weight: <15Kg