Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Current Transformer, Split Core Current Transformer, Split Current Transformer manufacturer / supplier in China, offering Waterproof Outdoor Split Core CT Current Transformer for Power Meter, 500/5A Split Core CT Current Transformer, 2500 AMP Accu CT Split Core Current Transformer 333mv Sensor and so on.

1
    YRS
General Supplier

Single Phase AC Voltage Current Transducer

Get Latest Price
Min. Order / Reference FOB Price
1 Set Contact Supplier
Local Area: Chaoyang, Liaoning, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Kind: Digital Transmitter
Type: AC Transmitter
Phase: Single

FUD-I/U SINGLE PHASE AC VOLTAGE CURRENT TRANSDUCER
Changing the measured AC current/voltage to the DC current/voltage output according to the linear scale Excellent temperature characteristic and good working stability Configuration compactness and briefness.
FEATURES
Single phase current / voltage transducer
AC current / voltage transducer
Accuracy class can reach 0.2%
AC input range can be customized
DC output range can be customizedMODEL DEscriptION
FUD-Type-Input-Power Supply-OutputTypeI: Single phase AC current transducer
U: Single phase AC voltage transducer
Ir: Single phase AC real RMS current transducer
Ur: Single phase AC real RMS voltage transducerAC inputA1: 0-1A, A2: 0-5A, A3: 0-10A.
V0: 0-70V, V1: 0-120V, V2: 0-250V,
V3: 0-300V, V4: 0-450V, V5: 0-500V.Power supplyP1: AC110V±10%, P2: AC220V±15%, P3: AC110V-330V.DC outputO1: 0-5V, O2: 1-5V, O3: 0-20mA, O4: 4-20mA, O5: RS485Example 1: FUD-I-A2-P2-O4FUD series single phase AC current transducerInput: AC0-5A
Power supply: AC220V±15%
Output: DC4-20mAExample 2: FUD-Ur-V3-P2-O4FUD series single phase AC real RMS voltage transducerInput: AC 0-300V
Power supply: AC220V±15%
Output: DC4-20mAPlease check the type, input range, output range and power supply when your order the product.
TECHNICAL INDEX
Technical IndexStandardGB/T 13850-1998, IEC688:1992Accuracy0.2%, 0.5%Consumption≤3VAAccuracy driftAnnual variation < 0.2%Insulation voltageAC 2kV/min.1mA (Between input- output / power)Insulation resistance≥20MΩ (DC500V)Surge voltage5KV (Peak value), 1.2/50μsResponse time≤350msInput rangeAC 0-10A ,AC 0-500V(Option), 50/60HzAbsorbed power<0.5VA/450V, <0.2VA/100V, <0.1VA/5AOverloadCurrent: 2 times continuous, 30 times /1s;
Voltage: 2 times continuousLoad resistanceCurrent output: RL≤550ΩVoltage output: RL≥2kΩWorking environmentTemperature: -10 to +50ºCRH: 20-90%, without condensationStorage conditionsTemperature: -40 to +70ºCRH: 20-95%, without condensationInstallation35mm DIN sliding-way or M4 screwsDimension55mm x 75mm x 120mm