FeaturesThese are epoch-making solenoid operated directional valves of high pressure, high flow which have been developed incorporating a unique design concept into every part of the valve including the solenoid. With wet type solenoids, these valves ensure the low noise and the long life, moreover, ensure no leakage of oil outside of the valve.Stable Operation
With a strong magnet and spring force, the valves are tough against contamination and thus ensure a stable operation.
Solenoids
Solenoid Connectors (DIN connector)
The solenoid connectors are conform to the international standard ISO 4400 (Fluid power systems and components-Three-pin electrical plug connectors Characteristics and requirements)
AC Solenoids
50 to 60 Hz common service solenoids do not require rewiring when the applied frequency is changed.
DC Solenoids (Reputable K-series)
These DC solenoids have surge absorbers for K-series functions. The three advantages of them are as mentioned below:
1. Since surge voltage can be controlled to a very low figure, electric control devices, such as a computer, can be used without any interference like noise.
2. There being no spark between contacts, the life of the relay becomes longer.
3. Time lag for spool return after de-energisation of the solenoid is very short.
SpecificationsValve TypeModel
NumbersMax. Flow
L /min
(U.S.GPM)Max. Operating
Pressure
MPa (PSI)Max. T-Line
Back Pres.
MPa (PSI)Max. Changeover
Frequency
min-1 (Cycles/Min)Approx. Mass
(kg)Standard
TypeDSG-01-3C∗-∗-5063 (16.6)31.5 (4570)
{Spool Type 60 Only
25 (3630)}16 (2320)300
{R Type Sol. Only}
1202.2DSG-01-2D2-∗-502.2DSG-01-2B∗-∗-501.6Shock less
TypeS-DSG-01-3C∗-∗-5040 (10.6)16 (2320)16 (2320)1202.2S-DSG-01-2B2-∗-501.6Solenoid RatingsValve TypeElectric sourceCoil
TypeFrequency
(Hz)Voltage (V)Current & Power at Rated VoltageSource RatingServiceable RangeInrush (A)Holding (A)Power (W)Standard
TypeShock less
TypeACA1005010080 - 1102.420.51―6010090 - 1202.140.371102.350.44A1205012096 - 1322.020.4260108 - 1441.780.31A20050200160 - 2201.210.2560200180 - 2401.070.192201.180.22A24050240192 - 2641.010.2160216 - 2880.890.15DC
(K Series)D12―1210.8 - 13.2―2.4529D242421.6 - 26.41.23D484843.2 - 52.80.61AC→DC Rectified (R)R10050/6010090 - 110―0.3329R200200180 - 2200.16Model Number DesignationF-S-DSG-01-2B2Special
SealsShock less
TypeSeries
NumberValve
SizeNumber
of Valve
PositionsSpool-
Spring
ArrangementSpool
TypeF;
For Phosphate
Ester Type
Fluids
(Omit if not
Required)None:
Standard
TypeDSG:
Solenoid
Operated
Directional
Valve013C:
Spring
Centered2,3,4,
40,60,9
10,122D:
No-Spring
Detened2B:
Spring
Offset2,
3,
8S:
Shock
less
Type3C:
Spring
Centered2
42B:
Spring
Offset2A-D24-C-N-50-LSpecial Two
Position Valve
(Omit if not Required)Coil
TypeManual
OverrideElectrical
Conduit
ConnectionDesign
NumberModels with Reverse Mtg. of Solenoid
(Omit if not required)―AC:
A100 A120
A200 A240
DC:
D12 D24 D48
R:
(AC→DC)
R100 R200None:
Manual
Override
Pin
C :
Push
Button
and
Lock Nut
(Option)None:
Terminal
Box TypeN:
Plug-in
Connector
Type
N1:
Plug-in
Connector
Type with
Indicator Light
(Option)50―――A
BL―DC:
D12 D24 D48
R:
(AC→DC)
R100 R200――L