Business Type:
Manufacturer/Factory,Trading Company
Business Range:
EN71, ISO8124 Toys Tester, Textile Testing Equipment, SATRAISO20344 Footwear Testing, Yarn Tester, Fiber Tester
Establishment:
2014
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
Eastern Europe, South America, Mid East
OEM/ODM Service
Sample Available

GESTER was established in Hongkong at 22th. April. 1997 (Manufacture for the Toys and Textile, Shoes Testing equipment) In 2006, Was established a factory in Dongguan of China.In 2008 became SGS, Bure...

1
    YRS
General Supplier
Supplier Homepage Tools & Hardware Tpp Thermal Radiant Performance Tester for Protective Clothing GT-RC02

Tpp Thermal Radiant Performance Tester for Protective Clothing GT-RC02

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $80000.00/ Set
Local Area: Quanzhou, Fujian, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: GESTER

Product Description

Tpp Thermal Radiant Performance Tester for Protective Clothing GT-RC02

Product introduction

The TPP thermal protection instrument is mainly used to measure the thermal insulation performance of flame-retardant protective clothing fabrics exposed to radiant heat sources and convection heat sources to detect the thermal protection performance of protective clothing, safety shoes, gloves, and helmet outer surfaces.

Key Feature

l The TPP Thermal Protection Tester include the sample holder assembly, the holder of the sample holder assembly, the heat source, the protective cover, the sensor assembly, the recorder, and the gasket. It shall also have a gas source, a gas flow meter, a burner, and a sensor.

l Removable corundum protection board, temperature 1800 degrees, can block the flame and reduce the test error.

l Two 45-degree Meker burners were placed to provide standard convection heat sources with nine quartz tubes.

l Meker burner diameter 38mm, internal hole diameter 5/16 inches, can provide 800-1200 BUT heat output, the burner mouth is a metal mesh structure, the burner lower air valve can be adjusted, adjustable air and flammable gas mixture proportion.

l Nine T150 quartz IR arrays provide thermal radiation flux of 13-40 kW/m2 ± 4 kW/m2.

l The total heat flux can be set to 83 kW/m2 ± 2 kW/m2 by adjusting the gas supplied to the Meker burner under the heat radiation of a quartz infrared tube.

l The calibration heat flow meter is water-cooled, with a working range of 0-100 kW/m2 and a maximum range of 150%.

l The response time of the heat flow meter is less than 200ms, the emissivity is greater than 0.95, and the output signal is greater than 5mv in the operating range.

l The copper pan calorimeter device can be used to detect convective heat and radiant heat, while detecting the temperature of the back of the specimen.

l The rotameter can adjust the flow of combustion gas with an accuracy of ±2% and a range of more than 3L/min.

l The pointer pressure gauge, the inlet pressure can be adjusted through the pressure reducing valve, the pressure relief valve has a range of 0-15psi.

l A quarter turn plug can manually shut off the flammable gas.

l The temperature acquisition system has a resolution of 0.1C° and an accuracy of ±0.75°C.

l The data acquisition speed of the automated data acquisition system is sub-/0.05 second and cold junction compensation is provided for thermocouple measurement data.

lTPP Thermal Protection Tester Equipped with computers and printers, comes with standard test software and provides standard test curves.

Product Image

Specifications

Climate Requirements

Propane and compressor air

Test Environment

25±5℃

Holding Way

Pneumatic or manual

Power Supply

220V 50Hz 15A

Dimensions

1500x540x460mm ((WxHxD)

Weight

86kg

mask testing machine

Packaging & Shipping

FAQ

FAQ

QIs your company a trading company or factory? AFactory + trade (integration), has 20 years focusing on test instruments field, 6 years exporting experience.QAfter an order is placed, when to deliver?AGenerally about 10-25days, If we have inventory, we can arrange shipment within 3 days. Please be aware that our production lead times depend on specific items and item quantities.QWhat’s the payment term?AT/T,L/C and other payment terms could be negotiated.QWhat's the warranty and after-sales service?A12 months warranty. Feedback to you within 24h and help you to repair your problem controller freely, even it's not from our factory.QWhat the standards do you adopt? AWe have been adopting the world standards and regulation such as ISO, ASTM, DIN, EN, GB, BS, JIS, ANSI, UL, TAPPI, AATCC, IEC, VDE, and CSA.QWhat about the product' services and quality?AEach instruments must be carried out 100% quality examination and test when shipping and delivery goods. Product use training, each of our product provide video training to show you how to install & operate. We can arrange engineer to train the operation of equipment to customer’s company when you need. And our Main clients : SGS, BV and Intertek.