Business Type:
Trading Company
Business Range:
Oscilloscope, DC Power Supply, AC Power Supply, Function Generator, Multimeter, DC ..
Establishment:
2009
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
T/T, PayPal, WesternUnion
Main Markets:
North America, Europe, Southeast Asia, Middle East
OEM/ODM Service
Sample Available

China Analog Oscilloscope 20MHz, CRT Component Tester Instruments, CRT Display manufacturer / supplier in China, offering China Oscilloscope 20MHz Analog Oscilloscope Component Tester Instruments CRT, Twintex Tp-3010 30V10A Regulated Linear DC Power Supply Single Channel, Twintex Tp-3020 Adjustable 0-30V 0-20A Digital Variable Linear DC Power Supply for Lab and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Electronic Instrument Oscilloscope Twintex Tos-2020CT China 20MHz Analog Oscilloscope Component Tester with CRT

Twintex Tos-2020CT China 20MHz Analog Oscilloscope Component Tester with CRT

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T, PayPal, WesternUnion
Kind: Analog Oscilloscope
Channel Number: 2
Structure: Desktop
Twintex TOS-2020CT China 20MHz Analog Oscilloscope Component Tester with CRTFeatures
Dual channel 20MHz/40MHz/50MHz
10 times sweep magnification
TV synchronization; X-Y mode
High illumination internal graticule CRT
Japanese encoded switch, reliable and durable
Fully sealed durable attenuation switch
ALT triggering function, enabling simultaneous observation of two independent signalsSelection guideModelTOS-2020BCH
TOS-2040BCH
TOS-2050BCHTOS-2020CF
TOS-2040CF
TOS-2050CFTOS-2020CT
TOS-2040CT
TOS-2050CTTOS-2020
TOS-2040
TOS-2050TOS-2020FG
TOS-2040FG
TOS-2050FGTOS-2100CMax. bandwidth20/40/50MHz20/40/50MHz20/40/50MHz20/40/50MHz20/40/50MHz100MHzAttenuator switch√√√√√Vertical encoder switchVertical pulse switch√Vertical sensitivity step101010101011High vertical sensitivity5mV/DIV5mV/DIV5mV/DIV5mV/DIV5mV/DIV2mV/DIVLow vertical sensitivity5V/DIV5V/DIV5V/DIV5V/DIV5V/DIV5V/DIVSweep encoder switch√√√√√Sweep pulse switch√Sweep time base step202020202022Fastest sweep time0.2us0.2us0.2us0.2us0.2us50nsSlowest sweep time0.5s0.5s0.5s0.5s0.5s0.5sDual sweep (Dual time base)√Time base step auto-shift√Trigger signal output√CH1 signal output√√Z-axis input√√√Trigger level lock√√Frequency counter√√Cursor readout√Panel settings save & recall√CRT illumination√Delayed sweep√Component test√
SpecificationsModel20MHz40MHz50MHzVertical systemSensitivity5mV~5V/DIV, 10 steps in 1-2-5 sequenceAccuracy≤3%; X5MAG: ≤5%Vernier sensitivity≤1/2.5 of panel indicated valueBandwidthDC~20MHz
(X5MAG: DC~7MHz)DC~40MHz
(X5MAG: DC~15MHz)DC~50MHz
(X5MAG: DC~15MHz)AC coupling<10Hz (at 100kHz, 8DIV, frequency response -3dB)Rise timeApprox. 17.5ns
(X5MAG: Approx. 50ns)Approx. 8.75ns
(X5MAG: Approx. 25ns)Approx. 7ns
(X5MAG: Approx. 23.3ns)Input impedanceApprox. 1MΩhttps://Approx. 25pFDC balance shift5mV~5V/DIV: ±0.5DIVVertical modeCH1, CH2, DUAL (ALT/CHOP), ADD, CH2 INVChopping repetition frequencyApprox. 250kHzInput couplingAC, GND, DCMax. Input voltage400V peak-peak, AC frequency≤1kHzCommon mode rejection ratio>50:1 at 50kHz sine wave (set CH1 and CH2 at same sensitivity)CH2 INV BALBalanced point variation≤1DIV (referred to graticule center)Horizontal systemSweep time0.2us~0.5s/DIV, 20 steps in 1-2-5 sequenceAccuracy±3%, X10MAG: ±5% (20ns~50ns/DIV uncalibrated)Vernier sweep time control≤1/2.5 of panel indicated valueSweep magnificationX10 (fastest sweep time 20ns/DIV)Position shift@X10MAG≤2DIV at CRT screen centerLinearity±5%, X10MAG: ±10% (0.2s~1us)Trigger systemTrigger modeAUTO, NORM, TV-V, TV-HTrigger level lockProvidedTrigger sourceCH1, CH2, ALT, LINE, EXTTrigger couplingAC: 20Hz to full bandwidthTrigger slope"+" or "-"SensitivityFrequency20Hz~2MHz2MHz~20MHz20MHz~40MHz40MHz~50MHzCH1, CH21DIV1.5DIV2.5DIV3DIVALT2DIV3DIVEXT200mV800mVTVSync pulse>1DIV (EXT: 1V)External trigger inputInput impedanceApprox. 1MΩhttps://Approx. 25pFMax. input voltage400V (DC+AC peak), AC frequency≤1kHzX-Y modeSensitivity5mV~5V/DIV±3%X-axis bandwidthDC~500kHz (-3dB)Phase error≤3° at DC~50kHzCH1 signal outputAt least 20 mV/div at 50Ω terminal, frequency at least 50Hz to 50MHzCalibration signal outputWaveformPositive-going square waveFrequencyApprox. 1kHzDuty ratio<48:52Output voltage2Vpp±2%Output impedanceApprox. 1kΩZ-axis inputBandwidthDC~2MHzSensitivity5VppInput impedanceApprox. 47kΩMax. input voltage30V (DC+AC peak), AC frequency≤1kHzFrequency counter (only for TOS-2020FG, TOS-2040FG, TOS-2050FG)Display6 digits LEDAccuracy±0.01%CRTType6-inch rectangular with internal graticule, 8x10DIV (1DIV=1cm)PhosphorP31Accelerating voltageApprox. 2kV (20MHz); Approx. 12kV (40MHz)Trace rotationAdjustable at front panelGeneralPower sourceAC110V/220V±10%, 50/60Hz, Max. 35VAAccessoriesPower cord x1, Operation manual x1, Probe x2Dimension (WxHxD)310x150x455mmWeightApprox. 8kg Specifications are subject to change without prior notice.