Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Ozone Analyzer
Establishment:
2018
R&D Capacity:
ODM, OEM
Terms of Payment:
LC, T/T
Main Markets:
Domestic
OEM/ODM Service
Sample Available

Gas Detector, Ozone Detector, Ozone Gas Analyzer manufacturer / supplier in China, offering Uvoz-3300c Ozone Gas Detector with LED Light Source, LED Display 4-20mA Output Online Ozone; Gas Monitor (O3), Air Quality Monitor; Ozone&; Gas; Analyzer; with Ce Certified (HCHO/VOCS) and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Analysis Instrument Gas Analyzer Uvoz-3000 Ozone Gas Detector with Touch-Screen for Ozone Generator

Uvoz-3000 Ozone Gas Detector with Touch-Screen for Ozone Generator

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $1.00/ Piece
Local Area: Zibo, Shandong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Brand: Zhiso
Customized: Customized
Portable: Non Portable
1.Company Introduction
Shandong ZHISO Environmental Tech Co., Ltd. is a joint company specialized in design & develop & selling of the instrument of environmental protection.ZHISO company is a professional R & D and sales company, mainly engaged in the UV detection method of ozone gas concentration principle and development of UV & infrared light absorption detection. We have our own manufacturer : Zibo Zhiprer Automation Technology Co., Ltd that mainly engaged in the production of UV ozone detector/ ozone gas analyzer.ZHISO company has it's own brand " ZHISO" and the main products are about:Ozone analyzer / Water quality / Toxic and harmful gas detector / Ozone generator. ZHISO company rely on the advantages & experience of high-level technical talents, to focuse on new products development. We are willing to cooperate with high-tech companies to work together for ozone application industry.
2.Product Introduction
UVOZ-3000 Ozone AnalyzerThe Principle: dual beam UV photometer absorption method, used to detect the outlet ozone concentration of generator or tail gas.
The Range: 0-1000ppm,0-100ppm(VOL)
The Features:This rack type analyzer can continuously running and automatic zeroing to ensure the stability of the detection.
The Brand:
A.Product Descriptionbased on Lambert Bill's law, the analyzer of UVOZ-3000 by measuring the change of the intensity of the light signal before and after the UV absorption to calculate the current ozone concentration.
The equipment adopts the advanced dual UV light source system with the intelligent management system of the lamp tube and separated photocell technology enables the analyzer has the characteristics of no leakage, anti high pressure, anti large-flow sampling gas impact.
The ozone analyzer has a touch screen operation interface, which shows the real-time ozone concentration. And the touch screen is also with the pressure & temperature compensation display. For the high concentration (g/Nm3) range, it has the function of flow input, which can display the output of the ozone generator in real time. .UVOZ-3000 Ozone Analyzer,Optional Range & Working Mode.RangeSampling MethodApplication Areas0-1000ppmActive pressure sampling, or pumping sampling, with pressure, temperature compensationReal-time detection of ozone concentration in box.0-100ppmActive pressure sampling, or pumping sampling, with pressure, temperature compensationReal-time detection of space or ozone concentration in room.
B.Technical ParameterModel : UVOZ-3000Detection Range:0-1000ppmOptional Range:0-1000ppm,0-100ppm(VOL), Light Source Life:about 30000 hoursSampling Method: active pressure sampling,pumping sampling(optional);Display Interface: 4.3 inch touch screen operation interfaceContent Interface: ozone concentration, temperture, pressureAuxiliary Function: temperature compensation and pressure compensationDisplay Unit:ppm(optional)Display Resolution: 0.01 ppm,Gas Flow:0.5L±0.2L/min;Input Pressure:<0.1MPa;Concentration Error : max 0.5%; Line Deviation : max 0.2%; Zero Drifting:<±0.3%.FS(whole range);Response Time : signal 0.03s, display 0.3s;Ambient Temperature : -20~50ºC;Pipeline Connection Mode:quick wring (stainless steel);Sampling Caliber of Series Connection:Φ8(8mm*6mm)(optional);Sampling Caliber of Bypass Connection:Φ6(6mm*4mm);Communication Mode:RS-485;(Need to be customized)Output Mode:4-20mA;(Need to be customized)Relay Signal: high alarm point relay signal, low alarm point relay signal.Power Supply:AC 110-220V;Dimension:160mm(height)x260mm(width)x300mm(depth);Free Warranty: 24 months (main engine);Note: standard configuration (built-in): flowmeter, ozone exhaust gas catalytic converter, air inputting filter. (Remark:1mg/L=1g/m3=467PPM)
C. Product FeaturesDetection Method:dual beam UV photometer absorption method, long life light source system, high measuring accuracy.Principle:according to Lambert Bill law, measure precisely by photometric absorption principle.Light Source System:imported long life uv light source system (wavelength 253.7nm), free warranty for 3 years.Using Method:indoor installation and use, configure power and signal terminals.Cuvette System:seperated optical cuvette with no leakage and anti high-pressure, high-flow rate, pmpact of sampling gas.Intelligent Compensation:built in temperature and pressure compensation and display, with automatic compensation function of light source.Operation Method:the user can select manual zeroing mode or automatic zeroing calibration according to the running state, and can set up automatic zeroing time.Display Unit:ppmDisplay Data:high definition color touch screen, setting the into-gas mass flow about high concentration range, real-time display the generator production.Output Function:4-20mA,RS485 communication(Need to be customized), two sets of alarm point output, electronic flowmeter input, etc.Standard Configuration:anti-corrosive flowmeter, ozone tail gas destroyer, gas in-putting filter.
D.Product StructureInlet-In: The ozone analyzer is connected to the inlet of the ozone pipeline in series, treat as an ozone inlet if by-pass sampling.
Inlet-Out: The ozone analyzer is connected to the outlet of the ozone pipeline in series,this hole will be blocked if by-pass sampling.
Outlet-Out: Ozone analyzer outlet, with built-in ozone destroyer, can be discharged indoors when there is no any ozone gas left.
Signal Terminal Output(01)4-20MA+ Current signal output (08)ALARM LOW : NO (02)4-20MA- Current signal output (09)ALARM LOW: COM (03)RS485+ communication interface
(Need to be customized)(10)ALARM LOW: NC (04)RS485- communication interface
(Need to be customized) (11)+ FLOW SIGNAL+
( Reservation function)(05)ALARM HIGH: NO (12)- FLOW SIGNAL-
( Reservation function)(06)ALARM HIGH: COM (13)+FUNCTION+
( Reservation function)(07)ALARM HIGH: NC (14)-FUNCTION-
( Reservation function)E. Connection Diagram
Touch-Screen Program Demo
3. Issues of concernA. PaymentTerms:
1.T/T,PAYPAL,WU,100%prepaid.
2.leadtime3-5daysafterpaymentB. OurService:
1.Allproductsandaccessorieshavebeen100%testedbeforeshipping.
2.Weprovide12monthswarantyon the host fornon-deliberatedamageC. F&Q:
Q1.Canihaveasampleoeder
A1:Thesampleoedertotestarewelcomedatthefirsttime.
Q2:Howaboutyourproductioncapacityandqualitycontrol?
A2:Wehavewritteninstructionsforincoming&inline&finalinspectionandtesting Allthequalifiedproductsmustbepassthe100%auditbyQEstaff.Andthefailed productswillbeclearlymarkedandseperatedtorepairandre-inspect.
Q3:Howcanigetagoodprice?
A3:Weare100%surethatwecanprovideyouthemostcompetitivepricewithhighvalues.Plstrus tusandattacheyourdetailrequest,oederquantity,deliverymode,paymentterms.