Business Type:
Manufacturer/Factory
Business Range:
Large Caliber Water Meter, Water Meter, IC Card Prepaid Water Meter, Remote Reading Water ..
Establishment:
2008
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T
Main Markets:
North America, Southeast Asia, Middle East
OEM/ODM Service
Sample Available

Water Meter, Cold Water Meter, Intelligent Meter manufacturer / supplier in China, offering GPRS Wireless Remote Reading Bulk Water Meter (LXSIC-40CA~LXSIC-200CA), Popular Lora Wan Prepaid Dry Smart Water Meter Manufacturer, GPRS Data Concentrator Terminal for Water Meter Collect and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Meter for Liquid & Gas Water Meter Vane Wheel Vertical Jet Water Meter (LXSL-15CB~LXSL-25CB)

Vane Wheel Vertical Jet Water Meter (LXSL-15CB~LXSL-25CB)

Get Latest Price
Min. Order / Reference FOB Price
500 Piece US $20.00/ Piece
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Install: Vertical
Medium Temperature: Cold Water
Level Measurement: B
Features: Vertical installation, Measuring accuracy, Clear reading, beautiful appearance
Technical Standards: CJ/T133-2001 & GB/T778.1LiquidSealedVaneWheelWaterMeter
Itisaliquidsealedwatermeterforresidentialapplicationinsizes15mm-50mmforcoldmeter.FEATURES
Mechanicaltransmissionmovementequatestomaximumreliability.
Thechamberoftherollersisliquidfilledsealedforprotectingtheinnerpartsfromthemoistureanddustpenetration.
Sealedwetdialregister.
Internalstrainer,inletstrainer.
Externalregulatingdevice,particularlysuitedinlowerqualitywater.StandardsCompliance
ISO 4064
Directive2004/22/EConmeasuringinstruments;theEuropeanStandardEN14154+A1+A2:WaterMeter;theInternationalOrganizationofLegalMetrologyOIMLR-49:2006(E)OptionalFeatures
Severallengthsandconnectionsavailableonrequest
NonreturnValveWorkingConditions
Watertemperature:≤50ºC
Waterpressure:≤1MPaor1.6MPaoptional
10baror16baroptional)Installationrequirements
Themetershouldbeinstalledinhorizontalpositionwiththeregisterfaceupwards.
Pipelinemustbeflushedbeforeinstallation.
Themetershouldbeconstantlyfullofwaterduringoperation.
Themetermustbeinstalledwiththedirectionoftheflowasindicatedbythearrowcastinthemeterbody.MAXIMUMPERMISSIBLEERROR
InthelowerzonefromQmininclusiveuptobutexcludingQtis±5%
IntheupperzonefromQtinclusiveuptoandincludingQsis:coldwatermeter±2%.