Smoke Detector, Smoke Detector En54, Conventional Smoke Detector manufacturer / supplier in China, offering High Quality Network Conventional Photoelectric Smoke Detector with En54-7 Approval, Circular LED Indicator for 360° Visibility Combined Smoke & Heat Detector, 2019 New Design Highlight Dual Color LED Indicator Heat Detector and so on.

1
    YRS
General Supplier
Supplier Homepage Security & Protection Alarm & Security Systems Alarm Host Wholesale Factory Price Conventional Control Panel for Fire Alarm System

Wholesale Factory Price Conventional Control Panel for Fire Alarm System

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $40.00/ Piece
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: Security Alarm Host
Function: Networked
Usage: Door, Auto, Personal, Window, Fire, Smoke, Gas,Heat

External (key-switch operated):

Reset/resound/test zone lamps evacuateSilence alarm soundersSilence fault sounders

Internal:

One man detector testZone isolateRevert to short-circuit: fire (no resistors in call points)

External indicators:

Sounder faultBattery/power supply faultMains onZone fireZone fault

Internal indicators:

Open circuit zone faultShort circuit zone faultZone isolatedEngineer test selected

Outputs:

Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)

Ancillary connections for expansion modules will allow the following:

Repeater panelsMultiple sounder outputsConnection to landlord panel

2 (0.8A SUPPLY)

4 / 6 (1.5A SUPPLY)

8/10/12/14/16/18

(4.0A SUPPLY)

POWER SPECIFICATION

MAINS SUPPLY VOLTAGE

230V±10%Va.c.50/60Hz

230V±10%Va.c.50/60Hz

230V±10%Va.c.50/60Hz

INTERNAL POWER SUPPLY

27 Vd.c.

27 Vd.c.

27 Vd.c.

TOTAL OUTPUT CURRENT LIMITED TO

800mA@240VAC

1500mA@240VAC

4000mA@240VAC

AUXILIARY POWER OUTPUT

27 Vd.c.

27 Vd.c.

27 Vd.c.

MAINS SUPPLY MonITORED FOR FAILURE

YES

YES

YES

BATTERY CHARGER MonITORED FOR FAILURE

YES

YES

YES

BATTERIES MonITORED FOR DISConNECTION AND FAILURE

YES

YES

YES

DETECTOR CIRCUIT SPECIFICATION

NUMBER OF CIRCUITS

2

4 or 6

8, 10, 12, 14,16,or 18

LINE FAULT MonITORED FOR OPEN CIRCUIT

YES

YES

YES

LINE FAULT MonITORED FOR SHORT CIRCUIT

YES (Can be disabled)

YES (Can be disabled)

YES (Can be disabled)

LINE FAULT MonITORED FOR DETECTOR REMOVAL

Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor

END OF LINE RESISTOR (SUPPLIED) VALUE

6800,5% tolerance,0.25W

6800,5% tolerance,0.25W

6800,5% tolerance,0.25W

DETECTOR ConTINUITY DIODES

Silicon 1N4001 or Schottky type(required if End of Line Monitor Unit fitted to give Detector Removal Fault)

CALL POINT RESISTOR VALUE (NOT SUPPLIED)

470 to 680, 0.5W

470 to 680, 0.5W

470 to 680, 0.5W

MAXIMUM NUMBER OF SMOKE DETECTORS PER ZONE

20(maximum detector current = 2mA)

20(maximum detector current = 2mA)

20(maximum detector current = 2mA)

MAXIMUM NUMBER OF MANUAL CALL POINTS PER ZONE

No limit

No limit

No limit

SOUNDER CIRCUIT SPECIFICATION

NUMBER OF CIRCUITS

2

2

2

END OF LINE RESISTOR VALUE

6800, 5%tolerance,0.25W

6800, 5%tolerance,0.25W

6800, 5%tolerance,0.25W

LINE FAULT MonITORED FOR OPEN CIRCUIT

YES

YES

YES

LINE FAULT MonITORED FOR SHORT CIRCUIT

YES

YES

YES

OUTPUTS FUSED AT

1 Amp

1 Amp

1.6 Amp

MAXIMUM TOTAL OUTPUT CURRENT ALL OUTPUTS

800mA

1500mA

4000mA

MAXIMUM NO OF BELLS @ 25 mA EACH BELL

32

56

120

MAXIMUM NO OF ELECTRonIC SOUNDERS @ 20 mA

40

70

150

AUXILIARY RELAY ConTACTS (DO NOT ConNECT MAINS VOLTAGES)

1A 30 Vd.c. max Voltage Free

1A 31 Vd.c. max Voltage Free

1A 32 Vd.c. max Voltage Free

FUSES-ALL FUSES COMPLIANT TO IEC (EN60127 PT2)

MAINS TERMINAL BLOCK

200mA T 20 mm

400mA T 20mm

630mA T 20mm

SOUNDER OUTPUTS

1A F 20mm

1A F 20mm

1.6A F 20mm

AUXILIARY OUTPUT

1A F 20mm

1A F 20mm

1A F 20mm

BATTERY FUSE

1.6A F 20mm

1.6A F 20mm

3A F 20mm

DOOR RETAINING MAGNETS

DO NOT USE PANEL POWER SUPPLY AS YOU WILL DRASTICALLY REDUCE BATTERY STAND-BY TIME

ConNECTION BLOCK

LARGEST ACCEPTABLE ConDUCTOR SIZE

2.5mm2

2.5mm2

2.5mm2

SMALLEST ACCEPTABLE ConDUCTOR SIZE

0.75mm2

0.75mm2

0.75mm2

DIMENSIONS

ENCLOSURE(WIDTH x HEIGHT x DEPTH)

415 x 265 x 100mm

415 x 265 x 100mm

415 x 265 x 100mm

WEIGHT(WITHOUT BATTERIES)

5100g

5200g

5500g