Hospital Equipment, Medical Equipment, Medical Supply manufacturer / supplier in China, offering Ysenmed One-Station Shopping Medical Hospital Equipment, Hospital Ysav200A Built-in Oxygen Air Blender Baby Neonatal Ventilator, Medical Ysvv500 Blood Locator Detector Finder Portable Vein Viewer and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Units | US $330.00/ Units |
Local Area: | Guangzhou, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, WesternUnion |
Brand: | YSENMED |
---|---|
Model Number: | YSME-DS7 |
Place of Origin: | Guangdong, China |
Instrument classification: | Class II |
YSME-DS7 portable auto BiPAP machine sleep ventilator therapy with integrated heated humidifier
auto BiPAP machine
Know the Differences Between CPAP and BIPAP Therapy
For the most part, CPAP machines have been the go-to treatment for obstructive sleep apnea. CPAP machines deliver a steady, continuous stream of pressurized air to patient's airways to prevent them from collapsing and causing apnea events. BiPAP (also referred to as BPAP) stands for Bilevel Positive Airway Pressure, and is very similar in function and design to a CPAP machine (continuous positive airway pressure).
Similar to a CPAP machine, A BiPAP machine is a non-invasive form of therapy for patients suffering from sleep apnea. Both machine types deliver pressurized air through a mask to the patient's airways. The air pressure keeps the throat muscles from collapsing and reducing obstructions by acting as a splint. Both CPAP and BiPAP machines allow patients to breathe easily and regularly throughout the night.
The main difference between BiPAP and CPAP machines is that BiPAP machines have two pressure settings: the prescribed pressure for inhalation (ipap), and a lower pressure for exhalation (epap). The dual settings allow the patient to get more air in and out of their lungs.
Product Parameters
Description
Auto CPAP
YSME-DS6
BIPAP
YSME-DS7
BIPAP
YSME-DS8
Working Mode
CPAP, Auto
CPAP, Auto, S, T, ST
CPAP, Auto, S, T, ST, APCV
Color
Silver
Dark Grey
Screen
2.8 inch TFT, 320 x 240
Pressure Range
4-20cmH2O, auto adjust
4-25cmH2O
4-30cmH2O
IPAP
4-20 cmH2O
4-25cmH2O
4-30 cmH2O
EPAP
N/A
4-20 cmH2O
Screen Auto Sleep
Auto sleep in 15 minutes, press any button to highlight screen
Data Storage
SD Card
Power Supply
Input 100-240V, 50-60Hz, 2-1A; Output +24V, 2.5A
DC Voltage
24VDC
Sound
<28db
Pressure Compensation
Yes
Backup Rate
N/A
5-50/min, adjustable
I/E
N/A
10-80%
Ramp Item
0-60min adjustable 1min/Step
Auto ON/OFF
Yes
Inspirate Triggle
N/A
1-5 level
Expirate Level
N/A
1-5 level
Inspirate Sensitivity
N/A
1-5 level
EPR
Yes
Auto-Altitude
Yes
Leak Compensation
Yes
Awake Detection
Yes
Breath Event Detection
Yes
Auto Pressure Titration
Yes
Mask Off Alarm
When mask is off, will Beep till mask put on or power off.
Power Off Alarm
If power is off when the machine is working, will make a warning sound over 30 seconds.
Water Capacity
220ML max
Humidifier Level
0-5 level
Humidifier
Integrated Heated Humidifier
Machine Dimensions(cm)
28L x 14W x 9.5H
Carton Dimensions(cm)
38L x 36W x 16H
Product Weight
1.6KG (Net Weight), 3.9KG (Gross Weight)
seline; line-height: 21.0000pt; background: #ffffff; margin: 0.0000pt 0.0000pt 13.5000pt 0.0000pt;">Do Not Overfill The Water Tub as Water May Enter The Device And Air Tubing!1. Place the device on a stable level surface.
2. Plug the power connector into the rear of the device. Connect one end of the power cord into the power supply unit and the other end into the power outlet.
3. Connect the air tubing firmly to the air outlet located on the rear of the device.
4. Open the water tub cover and fill it with distilled water up to the maximum water level mark. Do not fill hot water in the water tub.
5. Close the water tub cover.
6. Connect the free end of the air tubing firmly onto mask. For detailed information, read the mask user guide.
USE METHOD
seline; line-height: 21.0000pt; background: #ffffff; margin: 0.0000pt 0.0000pt 13.5000pt 0.0000pt;">Do Not Overfill The Water Tub as Water May Enter The Device And Air Tubing!1. Place the device on a stable level surface.
2. Plug the power connector into the rear of the device. Connect one end of the power cord into the power supply unit and the other end into the power outlet.
3. Connect the air tubing firmly to the air outlet located on the rear of the device.
4. Open the water tub cover and fill it with distilled water up to the maximum water level mark. Do not fill hot water in the water tub.
5. Close the water tub cover.
6. Connect the free end of the air tubing firmly onto mask. For detailed information, read the mask user guide.
Hot Sale