Business Type:
Trading Company
Business Range:
X ray machine, Ultrasound, Vet items, Dental items
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, WesternUnion
Main Markets:
Southeast Asia, Middle East, Africa, Others
OEM/ODM Service
Sample Available

Hospital Equipment, Medical Equipment, Medical Supply manufacturer / supplier in China, offering Ysenmed One-Station Shopping Medical Hospital Equipment, Hospital Ysav200A Built-in Oxygen Air Blender Baby Neonatal Ventilator, Medical Ysvv500 Blood Locator Detector Finder Portable Vein Viewer and so on.

1
    YRS
General Supplier
Supplier Homepage Furniture Outdoor Furniture YSME-DS7 portable auto BiPAP machine sleep ventilator therapy with integrated heated humidifier

YSME-DS7 portable auto BiPAP machine sleep ventilator therapy with integrated heated humidifier

Get Latest Price
Min. Order / Reference FOB Price
1 Units US $330.00/ Units
Local Area: Guangzhou, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, WesternUnion
Brand: YSENMED
Model Number: YSME-DS7
Place of Origin: Guangdong, China
Instrument classification: Class II

YSME-DS7 portable auto BiPAP machine sleep ventilator therapy with integrated heated humidifier

auto BiPAP machine

Know the Differences Between CPAP and BIPAP Therapy

For the most part, CPAP machines have been the go-to treatment for obstructive sleep apnea. CPAP machines deliver a steady, continuous stream of pressurized air to patient's airways to prevent them from collapsing and causing apnea events. BiPAP (also referred to as BPAP) stands for Bilevel Positive Airway Pressure, and is very similar in function and design to a CPAP machine (continuous positive airway pressure).

Similar to a CPAP machine, A BiPAP machine is a non-invasive form of therapy for patients suffering from sleep apnea. Both machine types deliver pressurized air through a mask to the patient's airways. The air pressure keeps the throat muscles from collapsing and reducing obstructions by acting as a splint. Both CPAP and BiPAP machines allow patients to breathe easily and regularly throughout the night.

The main difference between BiPAP and CPAP machines is that BiPAP machines have two pressure settings: the prescribed pressure for inhalation (ipap), and a lower pressure for exhalation (epap). The dual settings allow the patient to get more air in and out of their lungs.

Product Parameters

Description

Auto CPAP

YSME-DS6

BIPAP

YSME-DS7

BIPAP

YSME-DS8

Working Mode

CPAP, Auto

CPAP, Auto, S, T, ST

CPAP, Auto, S, T, ST, APCV

Color

Silver

Dark Grey

Screen

2.8 inch TFT, 320 x 240

Pressure Range

4-20cmH2O, auto adjust

4-25cmH2O

4-30cmH2O

IPAP

4-20 cmH2O

4-25cmH2O

4-30 cmH2O

EPAP

N/A

4-20 cmH2O

Screen Auto Sleep

Auto sleep in 15 minutes, press any button to highlight screen

Data Storage

SD Card

Power Supply

Input 100-240V, 50-60Hz, 2-1A; Output +24V, 2.5A

DC Voltage

24VDC

Sound

<28db

Pressure Compensation

Yes

Backup Rate

N/A

5-50/min, adjustable

I/E

N/A

10-80%

Ramp Item

0-60min adjustable 1min/Step

Auto ON/OFF

Yes

Inspirate Triggle

N/A

1-5 level

Expirate Level

N/A

1-5 level

Inspirate Sensitivity

N/A

1-5 level

EPR

Yes

Auto-Altitude

Yes

Leak Compensation

Yes

Awake Detection

Yes

Breath Event Detection

Yes

Auto Pressure Titration

Yes

Mask Off Alarm

When mask is off, will Beep till mask put on or power off.

Power Off Alarm

If power is off when the machine is working, will make a warning sound over 30 seconds.

Water Capacity

220ML max

Humidifier Level

0-5 level

Humidifier

Integrated Heated Humidifier

Machine Dimensions(cm)

28L x 14W x 9.5H

Carton Dimensions(cm)

38L x 36W x 16H

Product Weight

1.6KG (Net Weight), 3.9KG (Gross Weight)

seline; line-height: 21.0000pt; background: #ffffff; margin: 0.0000pt 0.0000pt 13.5000pt 0.0000pt;">Do Not Overfill The Water Tub as Water May Enter The Device And Air Tubing!

1. Place the device on a stable level surface.

2. Plug the power connector into the rear of the device. Connect one end of the power cord into the power supply unit and the other end into the power outlet.

3. Connect the air tubing firmly to the air outlet located on the rear of the device.

4. Open the water tub cover and fill it with distilled water up to the maximum water level mark. Do not fill hot water in the water tub.

5. Close the water tub cover.

6. Connect the free end of the air tubing firmly onto mask. For detailed information, read the mask user guide.

USE METHOD

seline; line-height: 21.0000pt; background: #ffffff; margin: 0.0000pt 0.0000pt 13.5000pt 0.0000pt;">Do Not Overfill The Water Tub as Water May Enter The Device And Air Tubing!

1. Place the device on a stable level surface.

2. Plug the power connector into the rear of the device. Connect one end of the power cord into the power supply unit and the other end into the power outlet.

3. Connect the air tubing firmly to the air outlet located on the rear of the device.

4. Open the water tub cover and fill it with distilled water up to the maximum water level mark. Do not fill hot water in the water tub.

5. Close the water tub cover.

6. Connect the free end of the air tubing firmly onto mask. For detailed information, read the mask user guide.

Hot Sale

YSME-DS7 portable auto BiPAP machine sleep ventilator therapy with integrated heated humidifier