Business Type:
Trading Company
Business Range:
X ray machine, Ultrasound, Vet items, Dental items
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, WesternUnion
Main Markets:
Southeast Asia, Middle East, Africa, Others
OEM/ODM Service
Sample Available

Hospital Equipment, Medical Equipment, Medical Supply manufacturer / supplier in China, offering Ysenmed One-Station Shopping Medical Hospital Equipment, Hospital Ysav200A Built-in Oxygen Air Blender Baby Neonatal Ventilator, Medical Ysvv500 Blood Locator Detector Finder Portable Vein Viewer and so on.

1
    YRS
General Supplier
Supplier Homepage Furniture Outdoor Furniture Yuesenmed Surgery Mobile Hospital Medical Breathing Machine

Yuesenmed Surgery Mobile Hospital Medical Breathing Machine

Get Latest Price
Min. Order / Reference FOB Price
1 Unit US $15.00/ Unit
Local Area: Guangzhou, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, WesternUnion
Brand: Ysenmed
Place of Origin: Guangdong, China
Product name: breathing machine
safety valve: <12.5 kPa

Yuesenmed Surgery Mobile Hospital Medical Breathing Machine

YSAV90B

Details:

TECHNIQUES SPECIFICATIONSPhysical specificationsDisplay10.4'' LCD DisplayMode:pneumatically powered and electrically controlled systemTrolley:Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisionsTechnical Specifications:Gas requirement:Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpasafety valve<12.5 kPaRespiratory Rate1 ~ 99 bpmgas concentration output21% ~ 100% adjustableMaximum Minute ventilation≥18L / minmodes of ventilationA/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUALVentilator compliance≤30 Ml/kPaPEEP:0 ~ 1.0 kPaPtr:-10 ~ 10 hPaIMV frequency:1~20 bpmI/E Ratio:4:1~1:4, Has the inverse ratio ventilationTidal VolumeSetting Range: 50~1500ML Display Range: 0~2000ml ;resolution ratio: 10mlInspiratory Plateau:0~1sMaximum Safety Pressure≤ 6.0kPaSigh:one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting pointPressure limit range:1.0~ 6.0kPaAirway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.1 kPa ~ 6.0 kPa;Upper: 0 ~ 5.0 kPa±0.2 kPaVentilation Volume alarm:≥ 18L/ MINPower Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120sThe airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.Operating conditionsAmbient temperature:10 ~ 40oCRelative humidity:no higher than 80 %Atmospheric pressure:860 hPa ~ 1060 hPaPower requirement:100-120 Vac, 50/60 Hz; Attention: the AC power supply used for the anesthesia machine must be well grounded.Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. StorageAmbient temperature:-15oC ~ +50oCRelative humidity:no higher than 95 %Atmospheric pressure:86 kPa ~ 106 kPa. It should be stored in a room without corrosive gas and well ventilatedPackagepackaging boxcomply with the requirement of GB/T 15464 Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation Moisture protection and rain protection to ensure that product is protected from natural damage.Safty & AlarmGas source pressureImmediate alarm; “high level alarm” indicator flickers raising an audible alarm.Airway Pressure AlarmThe airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm.Tidal Volume AlarmLower than 50ml, The alarm will be raised after one breathing cycle.Ventilation Volume AlarmLower: 0~12L/Min;Up: 18L/ MinBattery Voltage AlarmIt alrms when the battery voltage is lower than 10.5V.Power On Self TestSelf test before working, assure it's working normally.STANDARD CONFIGURATIONSQTYNAME1 setMain unit4 pcsAdult threaded pipe (Silica)1 setChild threaded pipe (single use)1 pcOxygen Tube1pcY-Pipe2pcsMask (Silicom)2pcsLeather Bag2pcsFuse1pcPower Line1pcOxygen pressure reducer4 pcsHoop1pcBattery1pcTools Attachment1 sethumidifier1 setEnglish Version User Manual

Other operation room equipment

medical ventilator medical ventilator medical ventilator medical ventilator