YUMO UB2000-30GM-E4-V152m distance liquid level measurement Ultrasonic sensorTechnical dataGeneral SpecificationsSensing distance 80…2000mmAdjustment range 120…2000mmUnusable area 0…80mmStandard target plate 100mmx100mmTransducer frequency about 112kHzResponse delay about 195msIndicators/Operating means LED blue Power onLED yellow indication of the switching state
Flashing:program function object detectedLED red permanently red: Error Red,flashing:program function,object not detectedElectrical specificationsOperating voltage UB 10…30VDC,ripple10%ssNo-load supply current ≤20mAInputInput type 1 TEACH-IN input Operating distance
A1:-UB…+1V,operating distanceA2:+6…
+ UB Input impedance:>4.7KΩ
TEACH-IN programmable pulse :≥1SOutputOutput type 1 switch output E5,PNP NO/NC,programmableRated operational current 200mA,short-circuit/overload protectedDefault setting Switching point A1:70mm Switching point A2: 800mmVoltage drop ≤ 3VRepeat accuracy ≤ 1%Switching frequency f ≤ 4HZRange hysteresis H 1% of the set operating distanceTemperature influence ± 1.5% of full-scale valueAmbient conditionsAmbient temperature -25…70ºC(248...343K)Storage temperature -40…85ºC(233...358K)Mechanical specificationsProtection grade IP67Connection V1 connector(M12x1),4-pinMaterial Housing brass,nickel-platedTransducer epoxy resin/hollow glass sphere mixture;
foam polyurethane,cover PBTWeight 25gCompliance with standards and diStandard conformity EN 60947-5-2:2007
IEC 60947-5-2:2007