Electric Numb Machine, Three Point Type, Slaughter Equipment manufacturer / supplier in China, offering Automatic Three Point Electric Numb Machine, Pig Dryer of Slaughtering Equipment, Cattle Pre-Stripping Line of Slaughtering Equipment and so on.

1
    YRS
General Supplier
Supplier Homepage Service Other Service Automatic Three Point Electric Numb Machine

Automatic Three Point Electric Numb Machine

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $22.00/ Piece
Local Area: Qingdao, Shandong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T
Application: Pig
Voltage: 380V
Automation: Automatic
The automatic three-point halo type brain hemp motor
the machine is a special equipment for killing pig hemp electricity, which is optimized and designed on the basis of our company's digestion and absorption of foreign advanced technology. It is the third generation replacement product of our company's straddle type hemp electric products. Since the product was put on the market, it has been identified by relevant departments that its performance indexes are in line with the requirements of the European Union equipment standard 89/392/ewg and relevant national standards, and its use performance has taken a leading domestic level, and it is currently large in China. First selection equipment of medium pig slaughtering plant
direction for use
1)The principle of mechanical transmission: the pig is driven into the pig driving road, automatically enters the saddle conveyor, and slides down the pedal to cross the conveyor belt, and the conveyor belt is sent to the hemp and electricity mechanism; At this time, the photoelectric induction signal is transmitted to the plc control center, the electrohemp cylinder solenoid valve is opened, the hemp brain electrode swings inward, the pig head is clamped, and at the same time, the active cylinder protrudes out, and the electric anesthesia mechanism is pushed out along the whole track. At this time, the anaesthesia electrode swung to carry on the cardiac anaesthesia; When the hemp is finished, the hemp electrode is reset and loosened, and the front baffle is raised by the cylinder. The pig has been knocked out by hemp electricity at the same time, and is released and slid down the slipway into the leachate plate conveying mechanism. Then the whole mechanism is brought back by the main cylinder and reset one by one, waiting for the next pig to send in and complete a new round of hemp electricity transmission.
2)When the automatic switch is turned on,
the automatic working mode can be manually operated. In this state, the automatic detection and execution of each work program can be carried out at the same time, if necessary, the manual control can be carried out at the same time.
3)When the automatic switch is turned on,
the automatic working mode can be manually operated. In this state, the automatic detection and execution of each work program can be carried out at the same time, if necessary, the manual control can be carried out at the same time.
4)Sensor adjustment:
there is an indicator light in front of the sensor, with a signal output on the light, a small screw on the side to adjust the effective distance of the sensor, and an increase in the clockwise distance. Note that the distance should not be adjusted too long so that the splint or the bottom plate will cause an induction error.
5)The function of the control adjusting knob in the control box is as follows:
the time of anesthetic delay is adjustable in 2-10 seconds for pigs,
the voltage of anesthesia is adjusted 30-180v for pigs.
6)Installation and test run:
according to the process requirements to do a good civil construction foundation, and then the whole machine is installed on the basis, the equipment before operation of the whole machine debugging, drive mechanism from slow to fast empty running for 10 minutes; Open the air compressor and the automatic switch of the anesthesia mechanism, debug, determine the expansion speed and the electric time of the cylinder of the hemp mechanism, after all normal, put into the test run.
The main points of safe operation are as follows:
1) the running speed of the conveying mechanism, the running speed of the electric apparatus and the time of the anesthesia are related to the output of the shift. once adjusted well, it is easy not to move in disorder so as to prevent the bad coordination of the various agencies and affect the quality of the hemp;
2) because of the high voltage of anaesthesia, the operator must avoid contact with the electrode in order to avoid electric shock.
3) this machine is suitable for the 80-140kg live pig automatic anesthesia electricity, the size too small or too big live pig should pay special attention to when the hemp electricity
4) strictly prohibits the machine to work the hand and so on other things into the machine, prevents the injury to the human or the damage machine;
5) if the machine appears abnormal working sound, it should stop to check immediately to prevent the machine from causing great damage and injury to the personnel;
6) the machine must be cleaned and maintained while stopping, and the power supply has been cut off and a warning plate is put up;
7) turn off the machine and cut off the power supply after work,
8) the operator should have the knowledge of mechanical and electrical operation and good health;
9) the operator should be familiar with the structure, performance, safety regulations and this instruction of the machine.
10) operators should be trained and certified to take up posts;
11) daily inspection should be conducted before each shift;
12) users must establish necessary rules and regulations and safety operating rules.
Inspection, maintenance, maintenance and troubleshooting methodsFault phenomenonPossible causeOverhaul methodDo not work after turning on the power supply, no indication of work indicator1. The power supply is not on or in bad contact 2. The circuit breaker in the control box is not closed 3. Fuse damage of controller1. Connect the power supply, deal with the bad part 2. Close the circuit breaker 3. Find the cause, replace the mental fuse.No automatic operation1. The automatic working switch is not on or out of order 2. Sensor lines or not well connected. Sensor adjusting distance is too close1. Overhaul or replace automatic switch 2. Reconnect line 3 according to wiring diagram. Readjusting the effective distance of the sensorTo keep repeating empty movements1. Sensor wiring error 2. Manual start button bad1. Readjust sensor effective range 2. Reconnect line 3 according to wiring diagram. Replace maintenance manual start buttonElectric electrodes or electric trolleys can not work1. The pressure is too low by two. Solenoid valve has no voltage (220v) 3. Mechanical moving parts jammed or rusted to death1. Adjust the gas pressure 2. Check solenoid valve coil and connection line 3. Repair or replacement of faulty partsNo voltage output during electric shock1. The hemp switch was not turned on. The electric voltage in the control box is not adjusted 3. Electric shock plate connection line broken1. Turn on the electric switch 2. Recalibrate the electric voltage of the anesthesia 3. Reconnect the plate circuitManual failure to work1. Manual start button damaged 2. Stop button damaged 3. Damage to control button of electric trolley1. Replace or maintain start button 2. Replace or repair stop button 3. Replacement or maintenance of car control buttonsTransmission non-rotation1. The frequency converter is not turned on or the switch is out of order 2. Frequency converter is not set 3. Frequency converter failure1. Replace switch 2. Reset 3 with reference to Inverter instruction. Replacement of maintenance frequency converterIf the above method can not solve the problem, please do not blindly remove, lest the scope of the fault expanded, please contact the technical department of the manufacturer repair.