Business Type:
Manufacturer/Factory,Trading Company
Establishment:
2012
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
North America, Europe
OEM/ODM Service
Sample Available

Zhangjigang Bestran Technology Co.,Ltd is established in 2000, we are a professional and quality-oriented manufacturer of hospital furniture and equipment,have advanced production management experienc...

1
    YRS
General Supplier
Supplier Homepage Furniture Outdoor Furniture BT-S1200 15 touch screen clinic patient transport mobile surgical surgery room Medical hospital ICU

BT-S1200 15 touch screen clinic patient transport mobile surgical surgery room Medical hospital ICU

Get Latest Price
Min. Order / Reference FOB Price
1 Unit US $10000.00/ Unit
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: Bestran
Model Number: BT-1200
Place of Origin: Jiangsu, China
Instrument classification: Class II

BT-S1200 15" touch screen clinic patient transport mobile surgical surgery room Medical hospital ICU Ventilator Machine Price

Product Description

Application

The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Indra-operation, post-operation respiratory support, other respiratory treatment.

Features

15” TFT LCD touch screen displays the ventilation parameters, alarm information and waveforms.

Air compressor runs stably with low noise, creates quiet environment for doctors and patients.

Integration breathing circuit design.

Multiple working modes such as volume control and pressure limit.

Multiple parameters monitoring interface to show clear parameter to the operator, allow operator know the patient conditions in all aspects.

Real time pressure-time, flow-time loop graphics, pressure volume loop graphics and high precision ETCO2, O2 concentration detection function included.

Electrical PEEP control

Breathing valve is disassembly and can be disinfected.

Safety

Three levels alarm system, visual and sound alarm information.

With multiple type of alarms, reminding and protection functions.

Self-check before running, eliminate system mulfuction.

Advanced power management control technology.

With built-in backup power supply, when normal power supply shut down, back-up power supply will start work automatically.

Separate design of electric and gas, keep safety running of ventilator.

Specifications

Ventilation modes:

IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV

Ventilator parameter ranges

Tidal volume(Vt)

0 ~ 2000mL

Frequency (Freq)

Oxygen concentration

1bpm ~ 100 bpm

21%-100%

I/E

4:1~1:8

PEEP

0cmH2O ~ 40 cmH2O

Pressure Limit

20 cmH2O ~ 100 cmH2O

Monitored Parameters

Frequency (Freq)

0 /min ~ 100 /min

Tidal volume(Vt)

0 mL ~ 2500 mL

MV

Airway pressure

Dynamic lung compliance testing

ETCO2 Concentration

0 L/min ~ 99 L/min

0 cmH2O ~ 100 cmH2O

1mL/cmH2O ~ 1000mL/cmH2O

0mmHg ~ 152mmHg (0%-20%)

Oxygen concentration

15 % ~ 100 %

Oscillographs display:

P-T(pressure – time)

F-T(flow – time)

P-V loop (pressure – volume loop)

V-T(volume – time )

ETCO2-T (End-tidal CO2 - time)

Alarms and protection

The AC power failure alarm

Power failure or no connection

Internal battery backup low voltage alarm

≤11.3±0.3V

No tidal volume

No tidal volume within 6s

High Minute Volume alarm

Low Minute Volume alarm

5L/min-99L/min

1L/min-30L/min

High Airway pressure alarm

Low Airway pressure alarm

High oxygen concentration alarm

Low oxygen concentration alarm

20cmH2O-100cmH2O

0cmH2O-20cmH2O

19%-100%

18%-99%

Continuous pressure alarm

(PEEP+1.5cmH2O) over 16s

Suffocation warning

Fan error

Oxygen deficit

5-60s

Show on screen

Show on screen

The maximum limited pressure

<12.5 kPa

Working conditions

Gas source

O2, AIR

Pressure

280kPa-600kPa

Voltage

~220V±22V

Power frequency

50Hz ± 1Hz

Input power

900VA (with air compressor)

250VA (without air compressor)

Ventilation modes:

IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV

Ventilator parameter ranges

Tidal volume(Vt)

0 ~ 2000mL

Frequence (Freq)

Oxygen concentration

1bpm ~ 100 bpm

21%-100%

I/E

4:1~1:8

PEEP

0cmH2O ~ 40 cmH2O

Pressure Limit

20 cmH2O ~ 100 cmH2O

Monitored Parameters

Frequence (Freq)

0 /min ~ 100 /min

Tidal volume(Vt)

0 mL ~ 2500 mL

MV

Airway pressure

Dynamic lung compliance testing

ETCO2 Concentration

0 L/min ~ 99 L/min

0 cmH2O ~ 100 cmH2O

1mL/cmH2O ~ 1000mL/cmH2O

0mmHg ~ 152mmHg (0%-20%)

Oxygen concentration

15 % ~ 100 %

Graphical display:

P-T(pressure – time)

F-T(flow – time)

P-V loop (pressure – volume loop)

V-T(volume – time )

ETCO2-T (End-tidal CO2 - time)

Alarm and protection

The AC power failure alarm

Power failure or no connection

Internal battery backup low voltage alarm

≤11.3±0.3V

No tidal volume

No tidal volume within 6s

High Minute Volume alarm

Low Minute Volume alarm

5L/min-99L/min

1L/min-30L/min

High Airway pressure alarm

Low Airway pressure alarm

High oxygen concentration alarm

Low oxygen concentration alarm

20cmH2O-100cmH2O

0cmH2O-20cmH2O

19%-100%

18%-99%

Continuous pressure alarm

(PEEP+1.5cmH2O) over 16s

Suffocation warning

Fan error

Oxygen deficit

5-60s

Show on screen

Show on screen

The maximum limited pressure

<12.5 kPa

Working conditions

Gas source

O2,AIR

Pressure

280kPa-600kPa

Voltage

~220V ±22V

Power frequency

50Hz ± 1Hz

Input power

900VA (with air compressor)