Business Type:
Manufacturer/Factory,Trading Company
Establishment:
2012
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
North America, Europe
OEM/ODM Service
Sample Available

Zhangjigang Bestran Technology Co.,Ltd is established in 2000, we are a professional and quality-oriented manufacturer of hospital furniture and equipment,have advanced production management experienc...

1
    YRS
General Supplier
Supplier Homepage Furniture Outdoor Furniture BT-S900B1 10.4 LCD Display Non-invasive low prices drager ventilator distributors

BT-S900B1 10.4 LCD Display Non-invasive low prices drager ventilator distributors

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $4700.00/ Piece
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: Bestran
Place of Origin: Jiangsu, China
Instrument classification: Class III
Certificates: ISO13485,CE

BT-S900B1 10.4' LCD Display Non-invasive low prices drager ventilator distributors

Product Description

Physical specifications Displaydrager ventilator is 10.4' LCD DisplayMode:drager ventilator is pneumatically powered and electrically controlled systemTrolley:

drager ventilator is Fitted with 4 nos anti-static rubber castors; two of which are

lockable for braking and easy maneuverability with foot operated brake provisions

Technical Specifications:Gas requirement: drager ventilator is Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpasafety valve <12.5 kPaRespiratory Rate1 ~ 99 bpmgas concentration output21% ~ 100% adjustableMaximum Minute ventilation≥18L / minmodes of ventilationA/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUALVentilator compliance≤30 Ml/kPaPEEP:0 ~ 1.0 kPaPtr: -1.0kPa~1.0kPa IMV frequency:1~20 bpmI/E Ratio:4:1~1:4, Has the inverse ratio ventilationTidal Volume range0~2000mlInspiratory Plateau:0~1sMaximum Safety Pressure≤ 6.0kPaSigh:

one deep breath per 80 controlled respirations, the inspiration time is 1.5 times

of the setting point

Pressure limit range:1.0~ 6.0kPa

Airway pressure alarm: Audible and visual and

with yellow and red color indicating

Lower: 0.1 kPa ~ 6.0 kPa;Upper: 0 ~ 5.0 kPa±0.2 kPaVentilation Volume alarm: ≥ 18L/ MIN Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s

The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm,

the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen

of the anesthetic respirator.

Operating conditionsAmbient temperature: 10 ~ 40oCRelative humidity:no higher than 80 %Atmospheric pressure:860 hPa ~ 1060 hPaPower requirement: 100-120 Vac, 50/60 Hz; Attention: the AC power supply used for the anesthesia machine must be wellgrounded.

Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993,

an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical

Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.

StorageAmbient temperature: -15oC ~ +50oCRelative humidity: no higher than 95 %Atmospheric pressure: 86 kPa ~ 106 kPa. It should be stored in a room without corrosive gas and well ventilated