Business Type:
Trading Company
Business Range:
ECG machine, B ultrasound machine, Endoscope camera systems, Patient Monitor, Ultrasound for vet
Establishment:
2016
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
Domestic Market, Africa, Southeast Asia
OEM/ODM Service
Sample Available

We ar a leading medical equipment manufacturer that is located in the Optical Valley of Hubei Province, the center of China.We founded in 2005, is devoted to the development of Ultrasound Imaging Syst...

1
    YRS
General Supplier
Supplier Homepage Furniture Outdoor Furniture CE ISO certificate digital display multi-purpose medical ICU ventilator machine

CE ISO certificate digital display multi-purpose medical ICU ventilator machine

Get Latest Price
Min. Order / Reference FOB Price
1 Unit US $2800.00/ Unit
Local Area: Wuhan, Hubei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: Visbull
Place of Origin: Hubei, China
Instrument classification: Class II
Ambient temperature: 5℃~+40℃

CE & ISO certificate digital display multi-purpose medical ICU ventilator machine

Product Description

KCH806 ventilator (digital) uses the latest design concept, the use of the electrical structure of the whole machine integrated. The compact gas path system makes the mechanical cavity of the ventilator smaller, faster and better.. The design of the machine makes the pressure, flow and capacity of the ventilator more accurate, and the coordination of the machine is increased..The compressor is equipped with a more precise change to the oxygen concentration.. Mixed tips for text, graphics, give you the most intuitive experience, improve the work efficiency while avoiding the medical risks caused by the operation.

Main performance and technical indicators

1. Breathing mode

A/C assisted control ventilation, SIMV synchronous intermittent instruction ventilation, PCV pressure control ventilation,PSV pressure support ventilation, SPONT spontaneous breathing, MMV instruction per minute ventilation,

IPPV intermittent positive pressure ventilation, SIGH sigh ventilation (deep breathing), PEEP positive airway pressure,

You SIMV+PSV, you SIMV+SPONT

2. Gas path performance

A) gas path maximum safe pressure: no more than 6kPa.

B) the concentration of inspiratory oxygen: 21% ~ 100%, continuously adjustable.

3.Ventilation performance

A) respiratory rate: 6 ~ 60 times / minute, continuously adjustable.

B) inspiratory time: 0.2 ~ 5S, continuous adjustable.

C) breath hold time: 0 ~ 2.5s, continuously adjustable.

D) the trigger pressure: -2kPa ~ 2kPa, continuous adjustable.

E) tidal volume: 50 ~ 1500ml continuously adjustable.

F) min ventilation: no less than 18 L/min.

G) PSV, PCV pressure: 0 ~ 5 kPa, continuous adjustable.

H) PEEP pressure: 0 ~ 2 kPa, continuously adjustable.

I) flow rate: 0.05 ~ 2 L/s, continuous adjustable.

SIMV) J frequency: 3 ~ 30 times / minute, continuously adjustable.

4.Alarm performance

A) the pressure limit of the alarm: 2 ~ 6kPa, continuous adjustable, sound and words show alarm.

B) the pressure limit of the alarm: 0 ~ 2kPa, continuous adjustable, sound and words show alarm.

C) ventilation volume limit alarm: ventilation more than set value (tidal volume set value x frequency setting value) of 50%, voice and words display alarm.

D) ventilation limit alarm: ventilation below the set value (tidal volume set value x frequency setting value) of 50%, voice and words display alarm.

E) air shortage warning: when the air pressure is less than 0.15MPa, the sound and light alarm.

F) oxygen shortage warning: oxygen pressure is less than 0.15MPa, sound and light alarm.

G) power failure warning: power failure alarm immediately, the alarm duration is not less than 120s.

H): no more than 2min.

5. Monitoring performance

A) tidal volume: 50 ~ 2000ml.

B) the measured total frequency and the autonomous frequency.

Breathe: (c) than the inspiratory time + breath hold time) / expiration time.

D) peak pressure: the highest airway and alveolar pressure.

E) airway pressure: airway and alveolar pressure.

F) airway pressure curve: the actual pressure and time curve of the airway.

G) velocity curve: the curve of the actual flow velocity and time of inspiratory.

Products Show

CE & ISO certificate digital display multi-purpose medical ICU ventilator machine

Packaging & Shipping

CE & ISO certificate digital display multi-purpose medical ICU ventilator machine

Our Services

CE & ISO certificate digital display multi-purpose medical ICU ventilator machine

Company Information

CE & ISO certificate digital display multi-purpose medical ICU ventilator machine

FAQ

CE & ISO certificate digital display multi-purpose medical ICU ventilator machine

ConTACT US

CE & ISO certificate digital display multi-purpose medical ICU ventilator machine

Janice Leung

Sales

Add: Room 521, Building 3, Mingshiyihao, Shucheng Road, Hongshan District, Wuhan, Hubei Province, China

Mobile/Whatsapp/Wechat: +86 13422568280

Tel: +86 27 87103315

Skype: janice_leung36