Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Chiller
Establishment:
2012
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea), Australia, Domestic
OEM/ODM Service
Sample Available

Chiller, Industrial Chiller, Water Chiller manufacturer / supplier in China, offering Air Cooled Water Chiller for HVAC, (Output Temp. -10c) Water Cooled Scroll Chiller, Air Conditioner Chiller_Water Plant Chiller Coolant Chiller_Plastic Machinery Parts Barrel Screwair Cooled Scroll Water Systems and so on.

1
    YRS
General Supplier

China 2016 Air Cooled Wine Chiller Price

Get Latest Price
Min. Order / Reference FOB Price
1 3N-50HZ, v Contact Supplier
Local Area: Shanghai, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment
Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral

2016 air cooled wine chiller price

wine chiller/air cooled wine chiller/wine chiller price

Winday Industrial is a professional industrial water chiller manufacture in Shanghai, China.
Successfully passed ISO9001 certification, CE certification, and has been successfully registered trademark "WINDAY".


Air cooled water chiller STRONG POINTS:

1Water chiller compressor brand is Copeland USA.Scroll compressor. Or Danfoss/Daikin/Sanyo optional is customer appointed2Heat exchanger/Evaporator is plate type or copper shell and tube type,copper tube wall thickness is 0.7mm3Condenser is Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger4Pump and water systems are stainless steel SUS3045High quality level electronic parts, Schneider/Siemens/LS6Designed chiller running life 10 years(running 8hr per day), 6 years(running 24hr per day). Warranty 1 year, 24 hours online after-sales servies team7Environment friendly refrigerant R410a/R407c/R134a, at least using R228Plywood export box packing9OEM available


Performance characteristics
1 high efficiency and energy saving, the heat transfer coefficient is 6000-8000W/m2.0C.
2 stainless steel manufacture, long service life, can reach more than 20 year
3 change laminar flow is turbulent, improves the heat exchange efficiency, reduces the thermal resistance.
4 heat transfer speed, high temperature (400 DEG C), resistant to high pressure (2.5Mpa).
5 has the advantages of compact structure, small occupation area, light weight, easy installation, saving construction investment.
6 flexible design, complete specifications, practical strong pertinence, save money.
7 conditions of application widely, applicable to large pressure, temperature range and a variety of medium heat exchange.
8 low maintenance cost, easy to operate, the cleaning cycle is long, easy cleaning.
9 the use of nano thermal film technology, significantly increase the heat transfer coefficient.
10 the broad field of application, and can be widely used in factories and mines, thermal power, petrochemical industry, city central heating, food and medicine, electronic energy, light industry machinery and other fields.



Air cooled water chiller performance characteristics

1 high efficiency and energy saving, the heat transfer coefficient is 6000-8000W/m2.0C.

2 stainless steel manufacture, long service life, can reach more than 20 year

3 change laminar flow is turbulent, improves the heat exchange efficiency, reduces the thermal resistance.

4 heat transfer speed, high temperature (400 DEG C), resistant to high pressure (2.5Mpa).

5 has the advantages of compact structure, small occupation area, light weight, easy installation, saving construction investment.

6 flexible design, complete specifications, practical strong pertinence, save money.

7 conditions of application widely, applicable to large pressure, temperature range and a variety of medium heat exchange.

8 low maintenance cost, easy to operate, the cleaning cycle is long, easy cleaning.

9 the use of nano thermal film technology, significantly increase the heat transfer coefficient.

10 the broad field of application, and can be widely used in factories and mines, thermal power, petrochemical industry, city central heating, food and medicine, electronic energy, light industry machinery and other fields.

Air-cooled water chiller parameters(output tem 5ºC)

ModelUNITWD-T 3AC/S5AC/S6AC/S8AC/S10AC/S12AC/S15AC/S20AC/S25AC/S30AC/SCooling capacityBtu28865.5246676.1659780.4072505.0097787.92110548.80144737.04202092.76221029.36289405.84RT2.43.895.286.048.149.2012.0516.8318.4024.10Kw8.4613.6818.6021.2528.6632.4042.4259.2364.7884.82x10³Kcal/h7.2311.7415.9918.3224.6527.8336.6051.0255.6573.05Total PowerKW3.255.306.068.1010..212.2316.3519.3022.0530.26Total CurrentA5.339.0611.4014.7118.0520.5429.3637.4340.2956.71CompressorQty11111111222.00Input powerKW2.624.355.106.518.569.6213.3816.3219.1526.52Operation CurrentA4.708.109.9112.7016.0017.7025.9032.6035.0051.70CondenserTypeEfficiency copper and Blue hydrophilic aluminum Finned heat exchanger FansInput powerKw0.260.5266.000.960.961.141.601.521.522.24Water Pipe ConnectionLnch0.651"2.002"2"2.8"3.5"4.8"4.8"5"EvaporatorTypeHorizontal shell-and-tube/Coil type high efficiency copper heat exchanger Freezing water FlowL/min24.0038.7060.0060.7081.7092.40121.20168.80184.80242.40Water pipe connectionLnch1"1"1"2"2"2"2"2.5"2.5"3"Freezing Water PumpTypeHigh efficiency,low noise Input PowerKw0.390.580.780.780.781.531.531.531.531.53Input CurrentM0.951.281.361.5813.003.503.503.503.503.50Lift of Outside of MachineBar15"20"22"22"20"17"25"24"18"18"Flow rateL/min100.00100.00100.00200.00200.00200.00360.00360.00650.00650.00RefrigerantType R22/R134A/R407C/R410A/R507/R404 Water tank Indicating VolumeLiter85.0090.0060.00190.00190.00190.00210.00255.00255.00255.00Safety protectionHigh and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. Dimensions (L*W*H)LengthMm1150115014151505150515051755206020602820WidthMm740740550850850850900102510251025HighMm1375137510001475147515501780191019102010Total WeightKG130.00200'230'350'350"400"420"520"735"1035"

Note:
1, the table refrigeration conditions: cold water inlet temperature 12 ºC, cold water temperature 7 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, crew safe operating range: Chilled water inlet temperature 9 ~ 20 ºC;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa)
6, In addition to the specifications and requirements, We can provide non-standard products according to customer requirements.
Air-cooled water chiller parameters(output tem -5ºC)

Model UNITWD-T 3AC/SM15AC/SM16AC/M18AC/SM110AC/SM112AC/SM115AC/S M120AC/S M125AC/S M130AC/S M1Cooling capacityBtu17401.2026681.8429697.3642513.5261279.5268717.6889189.68114165.52136650.60178447.60RT1.452.222.633.545.105.727.439.5111.3814.86Kw5.107.829.2412.4617.9620.1426.1433.4640.0552.30x10³Kcal/h4.386.747.9510.7015.4617.2822.5028.8034.5044.98 Total PowerKW3.405.327.428.4010.5012.5216.5020.4022.8330.56Total CurrentA5.339.0611.5014.7118.0520.5429.3637.4340.2956.71 Compressor Qty11111111222.00Input powerkw2.784.306.648.839.9213.4617.4019.8326.8520.30Operation CurrentA4.848.3912.7215.8617.5024.0529.5935.0048.0936.20CondenserTypeEfficiency copper and Blue hydrophilic aluminum Finned heat exchanger FansInput powerkw0.260.5166.000.960.961.141.601.521.522.24Water Pipe Connectionlnch0.651"2.002"2"2.8"3.5"4.8"4.8"5" Evaporator Type Horizontal shell-and-tube/Coil type high efficiency copper heat exchangerFreezing water FlowL/min15.7024.3060.0038.7055.8062.3081.30104.00111.50124.50Water pipe connectionlnch1"1"1"2"2"2"2"2.5"2.5"3"Freezing Water PumpType High efficiency,low noise Input PowerKw0.390.580.780.780.781.531.531.531.531.53 Input Currentm0.951.281.361.5813.003.503.503.503.503.50Lift of Outside of MachineBar16"21"17"17"16"18"26"25"25"19" Flow ratel/min100.00100.00100.00200.00200.00200.00360.00360.00650.00650.00Refrigerant Type R22/R134A/R407C/R410A/R507/R404 Water tank Indicating VolumeLiter85.0090.0060.00190.00190.00190.00210.00255.00255.00255.00Safety protection high and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. Dimensions (L*W*H) Lengthmm1150115014151505150515051755206020602820Widthmm740740550850850850900102510251025 Highmm1375137510001475147515501780191019102010 Total WeightKG130.00200'230'350'350'410'420'540'735.001035.00

Note:
1, the table refrigeration conditions: freezing glycol water inlet temperature 0 ºC, cold water temperature -5 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, this series of units used in low temperature conditions, to use 25% of the glycol for antifreeze coolants;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa);
6, In addition to the specifications and requirements, We can provide non-standard products according to customer requirements.
Air-cooled water chiller parameters(output tem -15ºC)

Model UNITWD-T 3AC/SM25AC/SM26AC/M28AC/SM210AC/SM212AC/SM215AC/S M220AC/S M225AC/S M230AC/S M2Cooling capacityBtu28865.5246676.1625965.3221461.4830946.8435143.6047085.6076155.8470355.4493966.48RT1.081.792.163.073.644.015.066.688.109.91Kw3.86.297.6110.812.814.117.823.528.534.9x10³Kcal/h3.215.216.549.2911.0112.1315.3120.2124.5130.01 Total PowerKW2.74.305.996.878.28.9012.2016.7317.6923.92Total CurrentA4.97.908.7111.814.415.921.628.531.042.3 Compressor Qty11111111222.00Input powerKW2.624.355.216.997.859.1414.7515.6918.2520.30 Operation CurrentA4.708.1011.7612.0716.7620.0232.3433.5340.0436.20CondenserTypeEfficiency copper and Blue hydrophilic aluminum Finned heat exchanger FansInput powerkw0.260.5266.000.960.961.141.601.521.522.24Water Pipe Connectionlnch0.651"2.002"2"2.8"3.5"4.8"4.8"5" Evaporator Type Horizontal shell-and-tube/Coil type high efficiency copper heat exchangerFreezing water FlowL/min21.0038.7060.0021.0030.3134.4645.9774.5668.9391.95Water pipe connectionlnch1"1"1"2"2"2"2"2.5"2.5"3"Freezing Water PumpType High efficiency,low noise Input PowerKw0.390.580.780.780.780.781.531.531.531.53 Input Currentm0.951.281.361.5813.003.503.503.503.503.50Lift of Outside of MachineBar15.0020.0022.0017.0016.0018.0025.0025.0019.0019.00 Flow ratel/min100.00100.00100.00200.00200.00200.00360.00360.00650.00650.00Refrigerant Type R22/R134A/R407C/R410A/R507/R404 Water tank Indicating VolumeLiter85.0090.0060.00190.00190.00190.00210.00255.00255.00255.00Safety protection high and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. Dimensions (L*W*H) Lengthmm1150115014151505150517551755222022202820Widthmm7407405508508509001200102510251125 Highmm1375137510001475147517801780197020702070 Total WeightKG130.00200'230'350'350'400'450'540'750'1050'

Note:
1, the table refrigeration conditions: freezing glycol water inlet temperature -10 ºC, cold water temperature -15 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, this series of units used in low temperature conditions, to use 25% of the glycol for antifreeze coolants;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa);
6, In addition to the specifications and requirements, We can provide non-standard products according to customer requirements.

After sales Services

1.Expire warranty we only just need you pay spare parts material cost fees, and also support maintenance service for free.

2.Irregular call tracking service, with 7*24 hours after sales .

3.We provide machine testing when customer come to our factory to see this machine.

4.We provide detail machine technical specification, electric diagram, installation book, operating manual, drawings

We can provide engineers to customer's factory to help installation and training workers if customer required.

Also offer OEM

* Customizable according to customer's requirements

Please do not hesitate to contact us, you will got our surprise