Business Type:
Manufacturer/Factory
Business Range:
Automatic Biochemistry Analyzer, Automatic ESR Analyzer, Assay Kit for Automatic ..
Establishment:
2007
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T
Main Markets:
Domestic
OEM/ODM Service
Sample Available

Erythrocyte Sedimentation Rate, ESR, Automatic manufacturer / supplier in China, offering Automatic Erythrocyte Sedimentation Rate (ESR-2020) Analyzer, Bio&Media Creatinine (CRE) Test Kit/Ivd Reagents/Hospital/Lab/Advanced Renal Disease/High-Efficiency, Bio&Media Urea (UA) Test Kit/Ivd Reagent/Uao-Pod Method/Hospital/Lab/High Stability/High-Efficiency and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine China Bio&Media Albumin Test Kit Ivd Reagent

China Bio&Media Albumin Test Kit Ivd Reagent

Get Latest Price
Min. Order / Reference FOB Price
10 box US $15.00/ box
Local Area: Jinan, Shandong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Type: Ivd Homocysteine Rapid Assay Kit
Quality Guarantee Period: 16 Months
Application: Hospital, Lab, School
The albumin (ALB) assay kit is intended for the accurate and direct quantitative measurement of ALB in human plasma.
Test principle
In specific buffer solution, positively charged ALB molecules react with negatively charged BCG molecules, forming the blue-green complex which shows absorption at the wavelength of 600 nm. The absorbance of this complex is proportional to the concentration of ALB.
ALB concentration can be calculated by comparing with the standard solution prepared in the same method mentioned above.
Product Features

1. Linear range of ALB level: [2, 60] g/L

Linear correlation coefficient ∣r∣≥0.990
Linear deviation ≤ ± 10.00%

2. Absorbance of blank ≤ 0.40

3. Sensitivity

The change in absorbance (ΔmA) ≥ 1.00 while testing the specific ALB sample of concentration of 35.3 g/L.

4. Accuracy

Relative deviation is within ±10%.

5. Precision

Intra CV% ≤ 5.0%; inter CV% ≤ 5.0%.
Technical Parameters

Temperature37ºCOptical path length (OPL)1.0 cmMain wavelength600 nmSecondary wavelength700 nm (Optional) MethodEnd-point method
(single reagent)Reaction directionPositiveSample5 μLReagent300 μLReaction time60 s

Reference range of ALB level: 35 - 50 g/L.
Packing Specifications
R: 2x50 mL
R: 6x50 mL
R: 1x40 mL (Sample)
Storage and stability
Unopened: Store assay kits at 10 - 30ºC protected from light. Stable to expiration date printed on individual vials (for 15 months).
Opened: Store assay kits at 10 - 30ºC protected from light. Stable for 1 month if kept capped from original container and free from contamination.
Do not freeze the assay kit.