Business Type:
Manufacturer/Factory
Business Range:
Automatic Biochemistry Analyzer, Automatic ESR Analyzer, Assay Kit for Automatic ..
Establishment:
2007
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T
Main Markets:
Domestic
OEM/ODM Service
Sample Available

Erythrocyte Sedimentation Rate, ESR, Automatic manufacturer / supplier in China, offering Automatic Erythrocyte Sedimentation Rate (ESR-2020) Analyzer, Bio&Media Creatinine (CRE) Test Kit/Ivd Reagents/Hospital/Lab/Advanced Renal Disease/High-Efficiency, Bio&Media Urea (UA) Test Kit/Ivd Reagent/Uao-Pod Method/Hospital/Lab/High Stability/High-Efficiency and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine China Bio&Media Cysteine-C Assay Kit Test Kit Ivd Reagent Renal Stable Efficient Hospital

China Bio&Media Cysteine-C Assay Kit Test Kit Ivd Reagent Renal Stable Efficient Hospital

Get Latest Price
Min. Order / Reference FOB Price
1 box US $300.00/ box
Local Area: Jinan, Shandong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Type: Hcy Assay Kit
Quality Guarantee Period: 12 Months
Application: Hospital, Lab, School
Homocysteine (Hcy) test kit allows an accurate and quantitative in vitro measurement of homocysteine (Hcy) concentration directly from human plasma. Hcy measurement is applied as an index for diagnosis of hyperhomocysteinemia and assessment of cardiovascular disease (CVD) risk. Hcy level is related with carotid atherosclerosis, and the concentration increases along with exacerbation of the disease. In cases of diagnosis of carotid atherosclerosis, Hcy measurement provides a more sensitive and reliable result compared to other tests. In addition to vascular disease, the increase of Hcy level is affected by some diseases such as neural tube defects, preeclampsia, Parkinson's disease, intrauterine growth retardation and chronic kidney failure and some drugs.
Product Features

1. Absorbance of blank ≤ 1.20.

2. Limit of blank ≤ 0.40 mg/L.

3. Sensitivity

The change in absorbance (ΔA) ≥ 0.04 while testing the specific Cys-C sample of concentration of 1.00 mg/L.

4. Linear range

Linear correlation coefficient ∣r∣≥0.990Linear range of Hcy level: [0.40, 7.50] mg/L

Linear rangeLinear deviation[0.40, 2.00]≤ ± 0.20 mg/L[2.01, 7.50]≤ ± 10.00%

5. Precision

Intra CV% ≤ 5.0%; inter CV% ≤ 10.0%.

6. Accuracy

Check the accuracy using the following methods (in order of priority):

7. Relative deviation is within ±15%

Packing Specifications
R1: 1x35 ml, R2: 1x7 ml
R1: 1x50 ml, R2: 1x10 ml
Storage and stability
Unopened: Store assay kits at 2 - 8ºC protected from light. Stable to expiration date printed on individual vials (for 12 months).
Opened: Store assay kits at 2 - 8ºC protected from light. Stable for 1 month if kept capped from original container and free from contamination.
Do not freeze the assay kit.