Business Type:
Manufacturer/Factory
Business Range:
Electric Transfer Pump, Transfer Pump Kit, Ex-Proof Pump, Fuel Flow Meter, Hose, Nozzle, ..
Establishment:
2018
R&D Capacity:
ODM, OEM
Terms of Payment:
LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment
Main Markets:
South America, Europe, Southeast Asia, Middle East
OEM/ODM Service
Sample Available

Ex-Proof Pump, Petrol Pump, Gasoline Pump manufacturer / supplier in China, offering 12V 20gpm Cars Cast Iron Replacement Fluid Fuel Transfer Pump, Positive Displacement LPG Gas Flow Meter Diesel Flow Meter, Positive Displacement Flow Meter Preset and so on.

1
    YRS
General Supplier

China Electric Transfer Pump Unit with CE Approval

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $108.00/ Piece
Local Area: Wenzhou, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment
Pumping Fuel: Diesel or Kerosene
Complete Pump Set: Pump+4m Delivery Hose+Manual Oil Nozzle+120L Flowm
Rated Voltage: AC220V or AC110V

Model No.: ZYB80-13A

(pump+4m delivery hose+manual oil nozzle+120L flowmeter)

Product introduction:The ZYB series oil pump unit is used for pumping light oils such as diesel or kerosene for vehicles, construction sites, farms or for other fuel powered equipment.
Technical Parameters:

Model

ZYB80-13A

Complete Pump Set

pump+4m delivery hose+manual oil nozzle+120L flowmeter

Rated Voltage

AC220V or AC110V

Rated Power

550W

Motor Turn Speed

1400r/min

Pump Flow Rate

(50-80)L/min

Meter flowrate

(20-120)L/min

Suction Lift

3-5m

Head Lift

5-10m

In-out

In BSPT1",Out BSPT1"

Flow Meter Digit

4 Digit,Max.9999.9 Liter,
8 Digit Accumulated

Environment condition:

Temperature: -25ºC---+55ºC
Relative Humidity: 30%--90%

High Atmospheric Pressure:86Kpa--106Kpa

Malfunction Diagnosis & Resolution:

Common Troubleshooting

Fault Apperance

Main Reason

Fault Resolution

Motor does not turn

1.The power cable is not plugged in

1.Check the electric cable

2.The motor has jammed

2.Replace the motor

3.Capacitor failure

3.Replace capacitors

Motor turns, but no oil output

1.Suction side not submerged in oil

1.Check the oil suction hose/pipe

2.Vanes worn or gear damaged

2.Replace vanes or gear

Abnormal metering or no meter output

Computation swing tray has broken

Replace the computation swing tray

Little oil-output

Plugged strainer

Clean the strainer