Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Gas Booster, Air Hydraulic Pump, Hydrostatic Test Machine
Establishment:
2012
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
T/T, D/P, PayPal, WesternUnion
Main Markets:
South America, Europe, Southeast Asia, Middle East
OEM/ODM Service
Sample Available

Hydraulic Test Pump, Hydrostatic Test Pump, Pressure Test Pump manufacturer / supplier in China, offering Hydraulic Hydrostatic Hydro Pressure Test Pump, Suncenter Brand Model: Dga25 25: 1 Pressure Ratio Air Driven Natural Gas Booster Pump for Charging Cylinders, Good Price Suncenter Model: 200 Bar Pressure High Pressure Pneumatic Driven Gas Booster Pump for Cylinder Filling and so on.

1
    YRS
General Supplier
Supplier Homepage Industrial Equipment & Components Pump & Vacuum Equipment Pressure Pump China Gas Booster for Oxygen Nitrogen Helium CO2 Cylinder Filling

China Gas Booster for Oxygen Nitrogen Helium CO2 Cylinder Filling

Get Latest Price
Min. Order / Reference FOB Price
1 set US $3000.00/ set
Local Area: Dongguan, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T, D/P, PayPal, WesternUnion
Max.Capacity: >400 L/min
Pressure Medium: Gas
Certification: CE, ISO

Gas booster for oxygen/nitrogen/helium/co2 cylinder filling

Suncenter - Gas booster systems are compact and delicacy solution tailored to customer specific requirements with gas boosters as well as all accessories to be fitted and installed in the frame or a closed cabinet.
To operate this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be set through a simple air regulator.
The pump stops automatically when this end pressure is reached and restarts with a slight drop in the outlet pressure or an increase in the air drive pressure.
Suncenter - Pneumatic booster system are used for oil free compression of clean shop air as well as industrial gases like Argon, Helium, Oxygen, Hydrogen and Nitrogen,CO2, etc..Driven air from 3 bar to 8 bar (from air compressor).
Operating pressure up to 80 MPa, for higher pressure, pump with double driven heads is an ideal option.
Applications

Pressure test with gasGas transfer and filling

(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)

Charging of gas cylinder and accumulator with nitrogenSupply for isolating gas systemsGas assisted injection moldingTransfer of oxygen cylindersCharging of breathing air bottlesLeak test Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft componentsSafety valve adjusting


Suncenter DGS Series Pneumatic (Air driven) Gas Booster Pump System
DGS booster system = booster pump+ following valves, gages, and parts
The hottest selling- model A and model C cabinet picture

The standard gas booster pumps system including following parts:
Air -driven gas booster pump (DGA/DGD/DGT three series for choosing)
Stainless steel (carbon steel) material cabinet (Three models for choosing)
F.R.L combination for driven air (adjusts air pressure, add lubricating oil and water filter)
Driven air switch (Pump starting switch), driven air pressure gauge
Gas inlet switch, Gas inlet pressure gauge
Gas outlet switch, Gas outlet pressure gauge, unloading valve, interconnecting pipes etc.
And we could also customize it according to clients' special requirement.
Technical specification for DGS-DGA series

ModelPressure boost ratioMin. gas
Inlet pressure
PA (bar)Max.gas
Inlet pressure
PA (bar)Max. gas
outlet pressure PB (bar)
Driven air pressure PLFormula to
calculate gas outlet pressure PBConnection:
Gas Inlet /
Gas outlet (ZG thread)Max. flow at driven air pressure of 6bar (L/min)DGS-DGA022:11.016162-8 bar2X PL1/2 / 1/2960 (at PA of 6 bar )DGS-DGA055:104040 2-8 bar5XPL1/2 / 1/2680(at PA of 6 bar )DGS-DGA1010:13.580802-8 bar10XPL3/8/ 3/8210(at PA of 10 bar )DGS-DGA2525:17.0 200200 2-8 bar25XPL1/4/ 1/4120(at PA of 20 bar )DGS-DGA4040:1103203202-8 bar40XPL1/4/ 1/4200(at PA of 40 bar )DGS-DGA6060:120 480480 2-8 bar60XPL1/4/ 1/4180(at PA of 40 bar )DGS-DGA100100:1258008002-8 bar100XPL1/4/ M14X1.5136(at PA of 40 bar )DGS-DGA130130:13580010402-8 bar130XPL1/4/ M14X1.5120(at PA of 40 bar )


Note: PL: driven air pressurePA: gas inlet pressurePB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar

Technical specification for DGS-DGD series

ModelPressure boost ratioMin. gas
Inlet pressure
PA (bar)Max.gas
Inlet pressure
PA (bar)Max. gas
outlet pressure PB (bar)
Driven air pressure PLFormula to
calculate gas outlet pressure PBConnection:
Gas Inlet /
Gas outlet (ZG thread)Max. flow at driven air pressure of 6bar (L/min)DGS-DGD1010:13.58080 2-8 bar10XPL+ PA3/8/3/8410(at PA of 6 bar )DGS-DGD2525:110 200200 2-8 bar25XPL+ PA1/4/1/4396(at PA of 20 bar )DGS-DGD4040:115 320320 2-8 bar40XPL+ PA1/4/1/4320(at PA of 40 bar )DGS-DGD6060:125 480480 2-8 bar60XPL+ PA1/4/1/4215(at PA of 40 bar )DGS-DGD100100:135 800800 2-8 bar100XPL+ PA1/4/M14*1.5300(at PA of 60 bar )


Note: PL: driven air pressurePA: gas inlet pressurePB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
Technical specification for DGS-DGT series

ModelPressure boost ratioMin. gas
Inlet pressure
PA (bar)Max.gas
Inlet pressure
PA (bar)Max. gas
outlet pressure PB (bar)
Driven air pressure PLFormula to
calculate gas outlet pressure PBConnection:
Gas Inlet /
Gas outlet (ZG thread)Max. flow at driven air pressure of 6bar (L/min)DGS-DGT2525:10.110200
2-8 bar25XPL+3.5XPA1/4/ 1/4136(at PA of 8 bar )DGS-DGT4040:10.110320
2-8 bar40XPL+ 6XPA
1/4/1/4124(at PA of 8 bar ) DGS-DGT10/6010:1/60:10.1104802-8 bar60XPL+6X PA
1/4/1/484(at PA of 8 bar )DGS-DGT25/6025:1/60:11025480
2-8 bar60XPL+2.5XPA
1/4/1/480(at PA of 15 bar )DGS-DGT100100:10.1108002-8 bar100XPL+10XPA1/4/ M14*1.563(at PA of 8 bar )


Note: PL: driven air pressurePA: gas inlet pressurePB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
How to Select Suncenter Air Driven Gas Boosters/Systems?
In order to choose suitable booster pump or systems for you,
please kindly reply us the following questions:
1.What is your present gas pressure?( )bar
2.What is your gas?oxygen gas,nitrogen gas or other gases?
3.What outlet gas pressure do you want?( )bar
4.What driven air pressure (of your air compressor) can you offer?( )bar,
because our booster is completely air operated and no need any electricity
5.What outlet gas flow rate do you need?( )L/min



Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.

Our main products including:
High Pressure Booster Pumps (Air Driven Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
High Pressure Systems (Gas/Liquid Booster Stations,FM200 filling machine, Tube Expanding Machine)
High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine,
Valve test bench,Impulse Testing Machine, etc.)

Product Application

Oil Industry, Gas Industry, Chemical Industry, Fire Fighting, Research Institutions etc.


Our service
13 months' free warranty since the purchasing date and free technical support during lifetime