Business Type:
Trading Company
Business Range:
Gas Booster, Gas Booster Pump, Air Hydraulic Pump, Gas Booster System, High Pressure ..
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
T/T, PayPal
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, East Asia(Japan, South Korea), Australia
OEM/ODM Service
Sample Available

Oxygen Gas Booster Pump, Oxygen Gas Booster, Oxygen Gas Pump manufacturer / supplier in China, offering Hot Item Model: GB40-Ol 200-300 Bar Air Driven Oxygen Gas Booster Pump for Diving Use, Usun Model: GB08t Double Acting Air Driven Argon/Helium/Nitrogen Gas Booster Pump, Usun Model: GB25 Air Driven Helium Gas Booster Pump for Helium Cylinder Transferring and so on.

1
    YRS
General Supplier
Supplier Homepage Industrial Equipment & Components Gas Generation Equipment & Parts China Oxygen Gas Booster Pump Oxygen Gas Booster Oxygen Gas Pump

China Oxygen Gas Booster Pump Oxygen Gas Booster Oxygen Gas Pump

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $1250.00/ Piece
Local Area: Dongguan, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T, PayPal
Max.Capacity: 100-200 L/min
Pressure Medium: Gas
Type: Handheld
USUN Model :GB40-OL 160MM driven single action air driven oxygen gasbooster pump for refilling oxygen gas cylinder

Usunair driven gas boosterpumpsare ratio devices that utilize low pressure compressed

airdriving a larger diameter piston (area x pressure) which is linearly connected to a smaller

hydraulicpiston/plunger. Using this ratio principal, a higher hydraulic pressure can be generated.

UsunPump model numbers reflect the pumps nominal pressure ratio, while the technical data

indicates exact ratios.The outlet stall pressure is easy to set by adjusting the air drive pressure

through a simple air pressure regulator. By multiplying the pressure ratio by the available shop

airpressure, the nominal gas pressure can be calculated.

Example ( Pump Model:GB25 Gas boosterpump)

Air drive piston area (160mm Ø)

Hydraulic plunger area (32mm Ø)

Actual ratio =25:1

1. AIR DRIVE SECTION

The air drive section consists of a light weight piston complete with seals running inside an

aluminumbarrel. The diameter of the air piston is160mm. When compressed air is supplied to

the pump the airpushes the air piston down on a compression stroke

(forces as out of the gas end).

Under thecontrol of pilot pins (poppet valve) triggered at each end of the stroke

2. GAS DRIVEN SECTION

ThegassectionofaUSUNairdrivengasboosterconsisitof4mainpieces

,thegasbarrel,thepistonthecheckvalvesandthemainhighpresUniversal Hardware Parts sureseals.

Thegaspistonisdirectlylinkedtotheairpistonanditishousedinsidethegasbarrel

anditsmovementsupanddowncreatesthegasflowintoandoutoftheboosterthrough

thecheckvalves.Thecheckvalvesarepsringloadedandonthesuctionstroke.the inlet check valve

opens to the maximum allowing gas into the gas barrel and on the compression stroke

the inlet check valve closes the discharge check valve opens forcing the pumped gas

into the process .Themainhighpressuresealsislocatedonthegaspistonandtheysealagaist
thegasbarrelduringoperation. and the maximum pressures of the pump ,however the

standard PTFE seals are suitable for both the vast majority of gases encountered.

Othermaterialsofconstructioncanbesuppliedtomeetmoreaggresiveservices

.Thestandardserialsofboosterarenotsuitableforundergroundcoalmineapplications.

USUNDOManufacturemodelsof air driven gas boostersthat aMachinery for Glass & Ceramics renotsuitable for undergroundcoal mine applications .

USUN Air driven gas boosters cycle automatically as the outlet pressure increass the

resistance alsoincreasesandthecycleratedecreasesuntilthepumpstopsautomatically

whentheoutputpressureforcesareequal.Thisisreferedtoasthestallcondition.

Thepumpwillrestartwithaslightdropintheoutlletpressureoranincreaseinthe airdrivenpressure
Boosterperformancecanbeaffectedbyanumberofconditions,

suchasfreezingoftheexhaustmufflerorpilotvalves(Whichiscausedbymoisturein

airlines),inadequateinletairlinesizesanddirtyfilers.When operatingtheboosters

onacontunuousbasis,werecommendyouuseamaximumcyclerateof50-60cyclesperminute.

Thiswillbothincreaseserviceintervalsandassistinpreventingiceformingattheexhaust.

Anairsupplydryerwillalsoassistinreducingicingup .

USUNGasboostershavea120mmstrokethusreducingcycleratesatanygivenflow

andpressureascomparedwithmostotherbrands.Thislowerrepsectivecyclerateres

ultsinareductioninfreeze-up condition.

Toabtainbestoverallperformance,donotreducetheindicatedportsizeandconsult


USUNforflowconditionsnotshownincharts Model selection for gas booster

ItisveryimportanttorememberthattheperformanceofanyairdrTimer & Counter ivendeviceisverydependentontheairsupplyconditions.Restrictionsintheairsupplycanbecausedbyusingatoosmallaircompressororairlines.TheFLOWCHARTSSHOWNinthetechnicaldatasheetarebasedongoodconditions .sopleasedonot"designtotheline"allowforlossesandinefficiencies

The next question is wheather you want the booster to stall when an outlet pressure is reached

If so ,a simple airline pressure regulator will suffice ,but remember the flow drops off dramatically as the

booster reaches a stall condition .

Ifyourequireflowataparticularpressure,thenyouneedreadtheflowcahrtscarefullyandconservatively

Ifyouneedthepumptostopatacertainpressure,priortostall,thenanairpilorswitchesneedstobeinstalled.

Key features

1. Realiable ,Easy to Maintain ,compact and robust

2. No heat,flame or spark risk

3. Infinitely variable cycling speed and output

4. Air driven Models do not require electrical connection ,easy to apply automatic controls

5. No limit or adverse affect to contineous stop/start applications

6.Seals system designed for long working life,No airline lubrHydraulic Press icated required

7.Built-in coupling system (Most models) and suitable for most gases boostingMain technical data
Typical technical data for air driven gas booster pump

ModelPressure ratioHigh pressure piston rod diameter (mm)Minimum inlet pressure PI(Bar)Maximum Outlet pressure PO(Bar)Outlet pressure formula POInlet port sizeOutlet porst sizeMaximumFlow rate L/min= 7 BarGB022.5:1100016.62PANPT1/2''NPT1/2''522@PI=7GB044:1801.233.24PANPT1/2''NPT1/2''354@PI=7GB05T5:1801.741.54PA+PINPT1/2''NPT1/2''572@PI=7GB077:1633.4567PANPT3/8''NPT3/8''252@PI=7GB08T8:1633.4647PA+PINPT3/8''NPT3/8''362@PI=7GB1010:1506.58010PANPT3/8''NPT3/8''196@PI=7GB1515:1408.112015PANPT3/8''NPT3/8''164@PI=10GB2525:1321520025PANPT1/4''NPT1/4''114@PI=20GB3032:1281825632PANPT1/4''NPT1/4''91@PI=20GB40 -OL40:1252532040PANPT1/4''NPT1/4''156@pi=40GB6060:1203248060PANPT1/4''NPT1/4''112@PI=40GB100100:11640800Other Bags & Cases 100PANPT1/4''NPT1/4''85@pi=40

Remark 1) Maxium outlet pressure are at an air driven pressure of 8 bar or 116 PSI ,for long life using

of such pump ,we suggest that air driven pressure should be not more than 8 Bar.Typical application of such air driven oxygen gas booster pump