Business Type:
Manufacturer/Factory,Trading Company
Establishment:
2012
R&D Capacity:
OEM, ODM, designandmanufacture
Terms of Payment:
LC, T/T, D/P, cash
OEM/ODM Service
Sample Available

Hydro Power, Generator, Power Plant manufacturer / supplier in China, offering Turbine Generator / Hydro Generator / Water Generator, Hydro Power Generator, Small Francis Hydro Turbine/Water Turbine Generator and so on.

1
    YRS
General Supplier
Supplier Homepage Industrial Equipment & Components Power & Generating Sets Hydro Generator China Small Francis Water Turbine Generator Small Francis Turbine

China Small Francis Water Turbine Generator Small Francis Turbine

Get Latest Price
Min. Order / Reference FOB Price
10 Set Contact Supplier
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, cash
Output Type: AC Three Phase
Size: Small
Type: Horizontal Hydro Generator
Small Francis Water Turbine Generator / Small Francis Turbine

Quick Detail:
Water Turbine type: Small Francis Turbine
Output Power:100KW to 50MW
Generator: Horizontal or Vertical

Frequency: 50HZ or 60HZ

Material: stainless steel


Description:
Francis turbine
Francis turbine is a kind of turbine suit to water head 20-300meters and with certain suitable flow.
It could be divided into vertical and horizontal arrangement. Francis turbine have the advantage of high efficiency, small size and reliable structure.

Horizontal Francis turbine unit, with horizontal shaft, could be 2 or three supports. Which is normally one stair arrangement. Simple structure, easier operation and maintainence.
Vertical Francis turbine unit, with vertical shaft, metal spiral case or concrete spiral case. With adjustable guide vane, and stay ring etc parts, are suit to runner diameter bigger than 1000mm. Our engineer will select the most suitable Francis turbine for your hydro power project.

Francis runner

Francis runner material could be stainless steel or carbon steel. The upper crown, lower ring, and blades are partial casted, polished, and then welded together. After heat treatment and fine polished, the factory tests including static and dynamic balance test, UT test, and dimension measurement. Our runners are guaranteed 100% all parameters meet the requirement, and related regulation.

Our service
Fuchun Industry Development Co., ltd Shenzhe is an experienced manufacture and engineering Company in small scale hydro power equipment ( 50Kw to 50Mw). We play the role of manufacture and EPC contractor and could supply water to wire equipments and services.
We provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.
1.Water Turbine Generator Unit Design & SUPPLY
2.Hydropower equipment supply
3.Feasibility study of hydropower project
4.Manufacture
5.Installation & Supervision
6.Commissioning and Training service
7. Hydro power plant rehabilitant
8. Hydro power plant spares supply
9.Services

Reference List of Some Export ProjectsNo.Country and Power Station Exported toTechnical ParametersTypeQtyDate of contract1HPP2
GuatemalaRated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480VCJA475-W-80/2x6.5
SFW1000-8/118012013.062 Pakistan Type:HL855a
Runner diameter:1750mm27Mw spare runners 12013.063UKRated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-55/1x712013.034turkeyRated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x8.5
SFW500-8/99012013.055Sri LankaRated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400VHLA550-WJ-62
SFW1000-6/118012013.056CongoRated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x9.5
SFW700-8/118012013.057
EcuadorRated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KVCJC601-W-100/1x5
SFW1980-6/143022012.128
Philippines Rated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440VZD-LH-160
SF320-36/215012012.129
GuatemalaRated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440VCJA475-W-80/2x9
SFW614-12/1180
CJA475-W-80/2x6.5
SFW302-12/99022012.1110UKRated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-55B/1x8.512012.1111 UKRated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400VHL110-WJ-4212012.1112UKRated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1113UKRated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1114UKRated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1115 HPP1
Guatemala Rated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440VHLA575c-WJ-56
SFW600-8/99022012.816UKRated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-40/1x9
SFW100-8/59012012.0417EcuadorRated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440VHL220-WJ-50
SFW470-8/99012012.0418Italy Rated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400VHL110-WJ-42
HLD54-WJ-4022012.0319 Pakistan Type:HL855a
Runner diameter:1750mm27Mw spare runners 32011.1120ITALYRated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA475-W-80/2x6.5
SFW250-10/85022011.0621ItalyRated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA475-W-85/1x9.5
SFW715-8/118032011.0522 UKRated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-42/1x10
SFW100-8/59012011.0323HPP1
AlbaniaRated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KVCJA475-W-105/2x7.5
SFW2150-8/173012010.1224 HPP2
AlbaniaRated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KVCJA475-W-115/2x8
SFW3000-8/173012010.1225 Italy Rated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD41-WJ-42
HLD74-WJ-6022010.1226
Afghanistan Rated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400VHL295-LJZ-50
SF500--6/85052010.1227
PakistanRated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kVCJA475-W-100/2x10
SFW1500-10/143022010.0828 HPP1
VietnamRated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kVHL69-LJ-205
SF37500-10/360022010.0229
MozambiqueRated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x9
SFW570-8/99012010.0430
Pakistan Rated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kVHLA696-WJ-68
SFW1000-8/118032010.0331 Italy Rated head:35m
Rated flow:4.25m³/s
Frequency:50HzHLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/99032010.0132Italy Rated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kVCJA475-W-110/2x8.5
SFW1600-10/173022009.0733GeorgiaRated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm4000KW Pelton runner change 32009.0634
VietnamRated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kVHLA883-LJ-155
SF17000-12/325022009.01