Business Type:
Manufacturer/Factory,Trading Company
Establishment:
2012
R&D Capacity:
OEM, ODM, designandmanufacture
Terms of Payment:
LC, T/T, D/P, cash
OEM/ODM Service
Sample Available

Hydro Power, Generator, Power Plant manufacturer / supplier in China, offering Turbine Generator / Hydro Generator / Water Generator, Hydro Power Generator, Small Francis Hydro Turbine/Water Turbine Generator and so on.

1
    YRS
General Supplier
Supplier Homepage Industrial Equipment & Components Power & Generating Sets Hydro Generator China Small Water Turbine for Hydro Power Plant Mini Hydro Turbine

China Small Water Turbine for Hydro Power Plant Mini Hydro Turbine

Get Latest Price
Min. Order / Reference FOB Price
10 Set Contact Supplier
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, cash
Output Type: AC Three Phase
Size: Small
Type: Horizontal Hydro Generator
small water turbine for hydro power plant / mini hydro turbine

Quick Detail:
Output Power:100Kw to 50Mw
Rate Head: 2m-1200m
Type: Francis, Pelton, Turgo, Kaplan, Tubular

Place of Origin: China (Mainland)

Rated Head: 2~1200m

Rated power: 50KW~50MW

Frequency: 50HZ or 60HZ

Voltage: 380V,400V,440V,3.3KV,6.3KV,6.6KV,10.5KV,ect.

Material: stainless steel


Description:
The Francis turbine are mostly suitable for hydro power station with medium or high head. The francis turbine we supply are compact in structure,reasonable in design,convenient in operation and maintenance and excellent in efficency. They are both vertical and horizontal shaft arrangement and can be vastly selected by the hydraulic power station.

Pelton turbine also called a free-jet turbine or Pelton wheel, a type of impulse turbine, named after L. A. Pelton who invented it in 1880. Water passes through nozzles and strikes spoon-shaped buckets or cups arranged on the periphery of a runner, which causes the runner to rotate, producing mechanical energy. The runner is fixed on a shaft, and the rotational motion of the turbine is transmitted by the shaft to a generator.
The impulse type turbines made by Fuchun are ranging from 80 to 1,000m in water head,200kW to 20MW in capacity and 0.55 to 2.3 in runner diameter. Theirs shaft arrangements are either vertical or horizontal and they may have single nozzle, twin or multi-nozzles.

Kaplan turbine also known as axial flow Turbine is developed in 1913 by the Austrian professor Kaplan.Its invention allowed efficient power production in low-head applications that was not possible with Francis turbines.The feature of Kaplan turbine is the water flow passes through the runner axially.

Kaplan turbines are widely used throughout the world for electrical power production. They cover the lowest head hydro sites and are especially suited for high flow conditions.
The tubular turbines are the best selection for exploitation of tidal power and hydraulic power with extremely low heads and extremely large flow rates. They have large discharge,high specific and high efficiency, and need less excavation.They have been classified into Bulb, Pit, Siphon and S" types in the light of their structural types.


Our service
Fuchun Industry Development Co., ltd Shenzhe is an experienced manufacture and engineering Company in small scale hydro power equipment ( 50Kw to 50Mw). We play the role of manufacture and EPC contractor and could supply water to wire equipments and services.
We provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.
1.Water Turbine Generator Unit Design & SUPPLY
2.Hydropower equipment supply
3.Feasibility study of hydropower project
4.Manufacture
5.Installation & Supervision
6.Commissioning and Training service
7. Hydro power plant rehabilitant
8. Hydro power plant spares supply
9.Services

Reference List of Some Export ProjectsNo.Country and Power Station Exported toTechnical ParametersTypeQtyDate of contract1HPP2
GuatemalaRated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480VCJA475-W-80/2x6.5
SFW1000-8/118012013.062 Pakistan Type:HL855a
Runner diameter:1750mm27Mw spare runners 12013.063UKRated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-55/1x712013.034turkeyRated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x8.5
SFW500-8/99012013.055Sri LankaRated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400VHLA550-WJ-62
SFW1000-6/118012013.056CongoRated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x9.5
SFW700-8/118012013.057
EcuadorRated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KVCJC601-W-100/1x5
SFW1980-6/143022012.128
Philippines Rated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440VZD-LH-160
SF320-36/215012012.129
GuatemalaRated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440VCJA475-W-80/2x9
SFW614-12/1180
CJA475-W-80/2x6.5
SFW302-12/99022012.1110UKRated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-55B/1x8.512012.1111 UKRated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400VHL110-WJ-4212012.1112UKRated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1113UKRated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1114UKRated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1115 HPP1
Guatemala Rated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440VHLA575c-WJ-56
SFW600-8/99022012.816UKRated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-40/1x9
SFW100-8/59012012.0417EcuadorRated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440VHL220-WJ-50
SFW470-8/99012012.0418Italy Rated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400VHL110-WJ-42
HLD54-WJ-4022012.0319 Pakistan Type:HL855a
Runner diameter:1750mm27Mw spare runners 32011.1120ITALYRated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA475-W-80/2x6.5
SFW250-10/85022011.0621ItalyRated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA475-W-85/1x9.5
SFW715-8/118032011.0522 UKRated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-42/1x10
SFW100-8/59012011.0323HPP1
AlbaniaRated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KVCJA475-W-105/2x7.5
SFW2150-8/173012010.1224 HPP2
AlbaniaRated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KVCJA475-W-115/2x8
SFW3000-8/173012010.1225 Italy Rated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD41-WJ-42
HLD74-WJ-6022010.1226
Afghanistan Rated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400VHL295-LJZ-50
SF500--6/85052010.1227
PakistanRated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kVCJA475-W-100/2x10
SFW1500-10/143022010.0828 HPP1
VietnamRated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kVHL69-LJ-205
SF37500-10/360022010.0229
MozambiqueRated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x9
SFW570-8/99012010.0430
Pakistan Rated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kVHLA696-WJ-68
SFW1000-8/118032010.0331 Italy Rated head:35m
Rated flow:4.25m³/s
Frequency:50HzHLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/99032010.0132Italy Rated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kVCJA475-W-110/2x8.5
SFW1600-10/173022009.0733GeorgiaRated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm4000KW Pelton runner change 32009.0634
VietnamRated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kVHLA883-LJ-155
SF17000-12/325022009.01