Business Type:
Manufacturer/Factory
Establishment:
2014
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
South America, Europe, Southeast Asia, Middle East
OEM/ODM Service
Sample Available

Lab Ion Sputtering Coater, Sem Ion Sputtering Coater, Ion Sputtering Coater Manufacturer manufacturer / supplier in China, offering Mini Size Ion Sputter Coater for Sem Sample Preparation, Multi-Layer Boards CNC Single Spindle Guide Hole Puncher with CCD Image System, Single Spindle CCD Camera Target Hole Drilling Punching Machine for Fr4 Glass Fiber Boards and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Physical Measuring Meter Other Physical Measuring Meters Electrolytic Thickness Gauge for Electroplating Process of Metal

Electrolytic Thickness Gauge for Electroplating Process of Metal

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $1.00/ Set
Local Area: Guangzhou, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Warranty: 1 Year
Condition: New
Usage: Width Measuring Instruments

Product Show
Product Description
Electrolytic Thickness Gauge is ametal plating electrolytic thickness gaugecombined with the most advanced technology at home and abroad, with advanced structure, stable and reliable performance, complete features. Using this instrument can guarantee the product quality of the user and prevent the waste of raw materials energy. The use of this instrument can also help users find thebest electroplating process for different requirements. It is the preferred instrument forfinished products and electroplating factories.
Main functions and features
1,Chinese and English interface switching, LCD display, high display quality, digital interface, small size, light weight, low power consumption, etc.
2,The thermal printer is permanently used without changing the ribbon. Micro-printing interface prints Chinese and English test report, print coating type, thickness, tester, date, internal clock perpetual calendar, no need to set each time
3,Automatic pause measurement prompts replacement of electrolyte. To reduce measurement error.
4,Automatically calculate the average. Below 10 microns is three decimal places, precision 1/1000
5,Measurable multilayer plating, such as: Cr/Ni/Cu/Plastic, reports can print out the results at once, without disassembly printing (exclusive).
6,Adjust the terminal potential difference to suit the potential between the coating and the substrate
7,By measuringmore than 70 kinds of metal plating substrate combinations, the electrolytic thickness gauge can measure plating on planes and surfaces, measuring small parts, wires, and linear parts.
8,Removal coating speed adjustable from 0.3-40 μm/minute.
9,The vacuum extruded air pump can be stirred by cycle, according to the coating, we can adjust the stirring intensity and gas volume to achieve the best dissolution state.
10,Electrolytic cup material iscorrosion-resistant alloy stainless steel,not easy to corrode aging.
11,Adjustable constant current to achieve the best value of electrolytic efficiency.
Technical Parameters
Single-layer measurement species
Nickel(0); Chromium(1) ;Copper(2); Zinc(3); Cadmium(4); Tin(5); Lead(6); Silver(7); Gold(8); Copper/Zn(9) ; Chrome/T(10); Nickel/Fe(11) etc, other coatings can be customized. Note: A, Nickel (0) is used for nickel plating on copper; Nickel/Fe (11) is used for nickel plating on iron, aluminum, plastics, and ceramics. It is measured at slow speed when measuring chemical nickel. B,Chromium (1) for decorative chromium and hexavalent and tetravalent chromium (0.001-20 μm); Chromium/T (10) for thick chromium above 20 μm. C,Copper (2) is used for copper plating on iron, aluminum, plastics, ceramics, etc. Copper/Zn (9) is used for copper plating on zinc and zinc alloys.
Alloy coating measurement
Pd-Sn,Cu-Zn,Zn-Ni,Ni-P,etc.
Multilayer plating measurement
Multilayer plating on ceramics, plastic, iron, aluminum and copper substrates
Effective measurement of thickness range
0.03~300μm
Measurement accuracy
±8%
Reproducibility
<3%
Electrolytic current accuracy
±0.5%
Measuring surface diameter
Φ3.0mm;Φ2.5mm;Φ1.7mm;
Power supply
A C220±10%V;0.7A;50HZ/60HZ±0.5HZ;good and reliable grounding is required.
selective purchasing
AC115V,100V,120V,230V,240V
Use environment
Temperature: +10~+40ºC; Relative humidity: not more than 85%; no strong corrosive gases and strong magnetic fields are required.
Weight of host
6Kg
Dimension
350x260x160mm(Length x width x height)
Noticewhenordering
1,The customer should confirm the substrate (this instrument is not restricted by any substrate).
2,Users should confirm the basal body and coating ,and the type and order of the coating.
3,According to customer needs choose the appropriate model.
4,The user should confirm the size of the test work piece.
5,Users must choose electrolytic thickness meter range:plastic, ceramic and other non-metallic coating thickness measurement, tin, nickel, silver metal plating thickness measurement, thickness measurement of multilayer plating, small workpiece coating thickness measurement, coating potential difference Analysis, dissolution analysis.
Note:This product can measure nickel, chromium, copper, zinc, cadmium, tin, silver, gold, zinc alloy plating, chemical nickel, etc. and many kinds of plating. This product cannot measure copper plating on multilayer nickel and copper, and it is impossible to analyze their potential difference (can be connected to a computer, analysis of measurement curve and measurement report).
If you need more further details about our products, please feel free to contact us.