Business Type:
Manufacturer/Factory,Trading Company
Business Range:
AC Current Transducer, Power Transducer, Voltage Transmitter & other Analysis Instruments, ..
Establishment:
2004
R&D Capacity:
OwnBrand
Terms of Payment:
LC, T/T
Main Markets:
Southeast Asia, Middle East, Domestic
OEM/ODM Service
Sample Available

Test Bench, Mater Test Bench manufacturer / supplier in China, offering DEC-9100 Series Single-Phase Test Bench Selection, Juxta Frequency Transducers, Juxta Power Factor Transducers and so on.

1
    YRS
General Supplier

Fpv, Fpvx, Fpvr, AC Voltage Transducers

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces Contact Supplier
Local Area: Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Voltage Type: AC Voltage
Input Signal Type: AC Voltage Transmitter
Output Signal Type: Analog Output
1. Applied Standards & Rules:
Measuring and conversion IEC 688 / 1992 - 04
Dielectrical strength IEC 688 2KVac / 1 min.
Surge and Impulse test ANSI C37.90 / 1989
IEC 255-3 (1989) 4KV 1.2 x 50 us2. Model:
FPV1 unit of avg. to rms conversion
FPVX 3 unit of avg. to rms conversion
FPVR Ture rms conversion3.Order form:
4.Input & Output parameters:
Py : DC24 / 48 / 125 V ± 20% or other range under specifiedNote:External power mode suitably for all output typesInternal power mode, only suitably for 0-1mA / 0-20mA / 0-1V / 0-5V / 0-10V output
5.Specification:
Accuracy ( 23±3°C ) 0.2% RO .......... FPA, FPAX, FPV, FPVX
0.2% RO .......... FPAR, FPVR
Maximum output load DC current mode : maximum 10V drop
DC voltage mode : maximum 5mA drive
Dielectric strengthAC 2KV 1 minute between terminals; AC 2.6KV 1 minute / terminals to case
Surge and impulse testANSI C37.90 / 1989, IEC 255-3 (1989) 4 KV 1.2 x 50 us
Maximum input over Current related input Voltage related input
1A / 5A 10A
4 x rated / continuous 2 x rated / continuous 1.5 x rated / continuous
10 x rated / 10 seconds25 x rated / 1 second 2 x rated / 10 seconds
50 x rated / 1 second 50 x rated / 0.5 second
80 x rated / 0.5 second
Input burdenCurrent less 0.2 VA; voltage less 0.1 VA
Response time & ripple Ø400 ms for step change 0-99% ripple less 0.5% ro peak to peak
Frequency 45 ~ 400 Hz
StabilityTemperature range ( 20 to 30°C )long term stability / year
Maximum 60 ppm / °C less 0.2% draft / year typically
Storage condition Temperature range -25 to 70°C, RH 20 to 95% non condensed
Operating condition Temperature range -20 to 65°C, RH 0 to 99% non condensed
Magnetic field effect < 0.01% under 100 ampere turns at 1M center
Power dissipationMaximum 3.5 VA for FPA / FPAR / FPV / FPVR; 8 VA for FPAX / FPVX6.Terminal Connection
ModelandOrdering
FPV-Vn-Fn-Pn-OnExample:1.FPV-V1-F1-P2-03Input:120V
AuxiliaryFrequency:50Hz
Power:AC220V
Output:4-20mAIf you have any questions about this,welcome to contact us.
We are all at service.
We can provide the product model and specifications:
ProductModel No.AC current transducerJD194-BS4I-NAC voltage transducerJD194-BS4U-NAC current transducerJD194-BS4IDC current transducerJD194-BS5IAC voltage transducerJD194-BS4UDC voltage transducerJD194-BS5UPower transmitterJD194-BS4PPower transmitterJD194-BS4QPower factor transducerJD194-BS4H7Frequency transmitterJD194-BS4F7Integrated transmitterJD194-BS4Z6Integrated transmitterJD194-BS4Z8Integrated transmitterJD194-BS4Z-STemperature transmitterBS6TResistance transducerBS6RIntelligent signal conditionerBS6MAC current transducerRPAAC voltage transducerRPVAC current transducerRPATAC voltage transducerRPVTAC current transducerRPAXAC voltage transducerRPVXPower transmitterRPWPower transmitterRPKPower transmitterRPWKPower factor transducerRPPFFrequency transmitterRPFFrequency transmitterRPFTAC current transducerCPAAC voltage transducerCPVAC current transducerCPATAC voltage transducerCPVTAC current transducerCPAXAC voltage transducerCPVXPower transmitterCPWPower transmitterCPKPower transmitterCPWKPower factor transducerCPPFFrequency transmitterCPFFrequency transmitterCPFTPower transmitterFPWPower transmitterFPKPower transmitterFPWTPower transmitterFPKTPower transmitterFPWKDC transducerFPD-1HDC transducerFPD-2HDC transducerFPDH-1HDC transducerFPDH-2HAC current transducerFPAAC voltage transducerFPVAC current transducerFPA2AC voltage transducerFPV2AC current transducerFPARAC voltage transducerFPVRAC current transducerFPATAC voltage transducerFPVTAC current transducerFPAXAC voltage transducerFPVXAC current transducerFPAX2AC voltage transducerFPVX2AC current transducerGPAAC voltage transducerGPVAC current transducerGPA2AC voltage transducerGPV2AC current transducerEPAAC voltage transducerEPVAC current transducerGPATAC voltage transducerGPVTAC current transducerGPAXAC voltage transducerGPVXAC current transducerGPAX2AC voltage transducerGPVX2AC current transducerGPASAC voltage transducerGPVSGenerator negative sequence current meterFPFX-100Temperature transmitterFT3Temperature transmitterFT2Temperature transmitterFT2-CTemperature transmitterGPTTemperature transmitterEPTShift transmitterFPBShare This Story, Choose Your Platform!