Business Type:
Manufacturer/Factory
Business Range:
Gas Sensor, Oxygen Sensor, Infrared Gas Sensor, PID Sensor
Establishment:
2004
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
T/T
Main Markets:
Europe, Southeast Asia, Middle East, East Asia(Japan, South Korea)
OEM/ODM Service
Sample Available

Membrapor, O3 Sensor, Water Treatment manufacturer / supplier in China, offering Electrochemical Ozone O3 Gas Detector Sensor Toxic Ambient Gas Monitoring, SF6 Plus O2 Infrared Gas Sensor IR NDIR Leak Alarm, Air Quality Chlorine Cl2 Gas Detector Disinfectant Toxic Gas Electrochemical and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Analysis Instrument Gas Analyzer H2O2 Hydrogen Peroxide Gas Sensor Detector 100 ppm Portable Devices Electrochemical Toxic Gas Compac

H2O2 Hydrogen Peroxide Gas Sensor Detector 100 ppm Portable Devices Electrochemical Toxic Gas Compac

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $9.00/ Piece
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T
Type: Electrochemical Gas Sensor
Conductivity Type: Volume Control Type
Output Signal Type: Digital Type
Gas Module Introduction
FAD gas module with two/three wire TTL/0-20mA/RS485 output, integrates toxic gas sensor + transmitter board. Adopting imported advanced electrochemical gas sensors, it has features of high accuracy, long lifetime, high stability and high anti-interference. The module is designed to prevent circuit reversed connection, high voltage, high current and lightning.
Gas Module Feature- Long lifetime imported advanced electrochemical sensors- High accuracy op ams, power supply IC, stable and sensitive - Detect low or high concentration toxic gases precisely- High anti-interference ability- Over range protection, reversed polarity protection and lightning protection- Low power consumption with a standard 4-20mA two/three-wire signal output- Interface: pump, diffusing, flange, flange thread types- 12-36VDC operating voltage Sensor Performance Characteristics (take H2O2/CB-100 as an example)Nominal Range0 - 100 ppmMaximum Overload200 ppmExpected Operation Life2 years in airOutput Signal1100 ± 300 nA/ppmResolution0.2 ppmTemperature Range-20 °C to 45 °C Pressure RangeAtmospheric ±10%Pressure CoefficientNo dataT90 Response Time< 60 secRelative Humidity Range15 % to 90 % R.H. non-condensingTypical baseline Range (pure air, 20°C)0-2 ppmMaximum Zero Shift(20°C to +40°C)No data Typical Long Term Output DriftN.D.Recommended Load Resistor10 OhmBias Voltage+300 mVRepeatability< 2 % of signalOutput LinearityLinear
Sensor Physical CharacteristicsWeight~ 13 gPosition SensitivityNoneStorage LifeSix months in containerRecommended Storage Temperature5 °C - 20 °CWarranty Period12 months from date of dispatch
Sensor Cross-sensitivity DataInterfering Gas ConcentrationReadingSO220 ppm~20 ppm
Performance data conditions: 20 °C, 50% RH, 1013 mbar
Module ParametersModule typeGM-I2(3)-M/C/S-**-****/G/P/F/FLDetected gasToxic gas Detecting principleElectrochemistrySamplingDiffusing pump flange threadResponding time30s~40s(of the sensor)Module accuracy≤±3%FS(actual concentration, higher accuracy depends on specified sensors)Module repeatability≤±2% FSModule linear error≤±2% FSModule zero temperature drift≤±2% (FS/year)Module operating temperature-40~80°CModule humidity0-95%RH(non-condensation)Sensor operating temperature-20°C~50°CSensor humidity0-90%RH(non-condensation)Signal outputTTL/4-20mA /RS485 (two or three wire)Transmitting distance1000 meters(RS485)Operating voltageDC 12-36VMaximum power≤0.8WSize80*48mmExplosion proofIntrinsic safeConnection cableRVVP3 x 1.5mm²
Module applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control