Business Type:
Manufacturer/Factory
Business Range:
Gas Sensor, Oxygen Sensor, Infrared Gas Sensor, PID Sensor
Establishment:
2004
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
T/T
Main Markets:
Europe, Southeast Asia, Middle East, East Asia(Japan, South Korea)
OEM/ODM Service
Sample Available

Membrapor, O3 Sensor, Water Treatment manufacturer / supplier in China, offering Electrochemical Ozone O3 Gas Detector Sensor Toxic Ambient Gas Monitoring, SF6 Plus O2 Infrared Gas Sensor IR NDIR Leak Alarm, Air Quality Chlorine Cl2 Gas Detector Disinfectant Toxic Gas Electrochemical and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Analysis Instrument Gas Analyzer O3 SO2 NO2 CO Cl2 Br2 CH2O ETO Alc CO H2 H2O2 H2S HCl HBr HCN NH3 NO PH3 SiH4 O2 Gas Sensor Detector

O3 SO2 NO2 CO Cl2 Br2 CH2O ETO Alc CO H2 H2O2 H2S HCl HBr HCN NH3 NO PH3 SiH4 O2 Gas Sensor Detector

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $6.00/ Piece
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T
Type: Electrochemical Gas Sensor
Conductivity Type: Volume Control Type
Output Signal Type: Analog Type
Gas Module Introduction
FAD gas module with two/three wire TTL/0-20mA/RS485 output, integrates toxic gas sensor + transmitter board. Adopting imported advanced electrochemical gas sensors, it has features of high accuracy, long lifetime, high stability and high anti-interference. The module is designed to prevent circuit reversed connection, high voltage, high current and lightning
Gas Module Feature- Long lifetime imported advanced electrochemical sensors- High accuracy op ams, power supply IC, stable and sensitive - Detect low or high concentration toxic gases precisely- High anti-interference ability- Over range protection, reversed polarity protection and lightning protection- Low power consumption with a standard 4-20mA two/three-wire signal output- Interface: pump, diffusing, flange, flange thread types- 12-36VDC operating voltage
O3 Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-5O3/M-5O3/C-5O3/S-5-S0-100O3/M-100O3/C-1000-200O3/C-2000-1000O3/C-10000-5000O3/C-50000-30000O3/S-30000 Cl2 Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-20Cl2/M-20Cl2/C-20Cl2/S-20-SCl2/S-200-50Cl2/S-50-SCl2/S-500-200Cl2/M-200Cl2/C-200Cl2/S-200-SCl2/S-2000-2000Cl2/C-20000-5000Cl2/C-5000Alc Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompact0-100Alc/C-1000-200Alc/M-200H2 Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-1000H2/M-1000H2/CA-1000
H2/CB-1000H2/SA-1000-SH2/SA-10000-2000H2/C-2000H2/S-2000-SH2/S-20000-4000H2/M-40000-5000H2/C-50000-10000H2/CT-10000H2/S-10000-S0-20000H2/C-20000H2/SA-20000-S0-40000H2/M-40000H2/C-40000
H2/CT-40000H2O2 Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompact0-100H2O2/MB-100H2O2/CB-1000-500H2O2/MB-500H2O2/CB-5000-2000H2O2/CB-2000HCl Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompact0-20 ppm HCl/M-20HCl/C-200-20 ppmHCl/M-200HCl/C-2000-1000 ppmHCl/C-10000-3000 ppmHCl/C-3000HCN Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-50 ppm HCN/M-500-100 ppmHCN/M-100HCN/C-100HCN/S-100-SHCN/S-100O2 Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-50 ppm HCN/M-500-100 ppmHCN/M-100HCN/C-100HCN/S-100-SHCN/S-100PH3 Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-5 ppm PH3/M-5PH3/C-5PH3/S-5-SPH3/S-50-20 ppmPH3/M-200-200 ppmPH3/M-2000-500 ppmPH3/C-5000-1000 ppmPH3/C-10000-2000 ppmPH3/M-2000PH3/C-20000-4000 ppmPH3/C-4000NO2 Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-1 ppm NO2/C-10-20 ppmNO2/M-20NO2/C-20NO2/S-20-S0-100 ppmNO2/M-100NO2/S-1000-500 ppmNO2/M-500NO2/C-500NO2/S-500-S0-1000 ppmNO2/S-1000-SNO2/S-10000-2000 ppmNO2/S-2000-S0-5000 ppmNO2/S-5000-SCH2O Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-10CH2O/M-10
CH2O/M-10-2ECH2O/C-10CH2O/C-100-50CH2O/M-500-1000CH2O/M-1000CH2O/C-1000SiH4Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-50 ppm SiH4/M-50SiH4/C-50SiH4/S-50-SSiH4/S-50SO2 Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-1SO2/C-10-20SO2/M-20
SO2-M-2E
SO2/MF-20SO2/C-20
SO2/CF-20SO2/S-20-SSO2/S-200-100SO2/M-100-2E
SO2/MF-100SO2/C-100
SO2/CF-100SO2/SF-100-SSO2/S-20
SO2/SF-200-200SO2/MF-2000-400SO2/SF-400-S0-1000SO2/MF-10000-2000SO2/MF-2000SO2/C-2000
SO/CF-2000SO2/S-2000-S
SO2/SF-2000-S0-10000SO2/MF-10000SO2/CF-10000SO2/SF-10000-SH2S Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-10 ppm H2S/C-10H2S/S-50
H2S/SP-500-50 ppmH2S/M-50H2S/C-50H2S/S-50-S0-100 ppmH2S/M-100H2S/CG-100-4E
H2S/CP-1000-200 ppmH2S/M-200-2EH2S/C-200H2S/SG-200-SH2S/S-2000-500 ppmH2S/M-500H2S/C-500
H2S/CP-5000-1000 ppmH2S/C-1000H2S/S-1000
H2S/SP-10000-2000 ppmH2S/M-2000H2S/C-2000
H2S/CG-2000
H2S/CP-2000H2S/SG-2000-S0-5000 ppmH2S/C-5000
H2S/CP-5000H2S/S-50000-10000 ppmH2S/CP-10000H2S/S-10000-SH2S/S-10000
H2S/SP-10000C2H4 Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-10C2H4/M-10C2H4/C-10C2H4/S-10-SC2H4/S-100-200C2H4/M-200C2H4/C-200C2H4/S-200-SC2H4/S-2000-1500C2H4/M-1500C2H4/C-1500C2H4/S-1500-SC2H4/S-1500ETO Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompact0-10ETO/M-100-20ETO/M-20ETO/C-200-100ETO/M-100ETO/C-1000-500ETO/M-5000-1000ETO/M-1000ETO/C-10000-50000ETO/C-5000CO Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-200CO/MF-200CO/C-200
CO/CF-200
CO/CF-200-4E
CO/CFA-200CO/SF-200-S
CO/SF-200-4E-S
CO/SFA-200-SCO/SF-200
CO/SF-SFA-2000-500CO/MF-500
CO/MFA-500CO/CF-500
CO/CFA-500CO/SF-500-SCO/SF-5000-1000CO/MF-1000CO/C-1000
CO/CF-1000
CO/CFA-1000CO/S-1000-S
CO/SF-1000-S
CO/SFA-1000-SCO/S-1000
CO/SF-1000
CO/SFA-10000-2000CO/MF-2000CO/CF-2000
CO/CF-2000-4ECO/SF-2000-S
CO/SF-2000-4E-S
CO/SGF-2000-4E-SCO/SF-20000-4000CO/CF-4000CO/SF-4000-SCO/SF-40000-5000CO/CFA-50000-10000CO/CF-10000-4E
CO/CFA-10000CO/SF-10000-4E-S
CO/SFA-10000-4E-SCO/SFA-100000-40000CO/CF-40000CO/SF-40000-SNO Sensor Detecting Range SelectionDetecting range (ppm)/SizeMiniatureCompactSlimStandard0-1NO/C-10-25NO/M-25NO/C-25NO/S-25-SNO/S-250-100NO/C-100
NO/CF-100NO/S-100-S
NO/SF-100-SNO/S-100
NO/SF-1000-200NO/SF-200-S0-250NO/M-2500-1000NO/M-1000NO/SF-1000-SNO/S-10000-2000NO/CF-2000NO/SGF-2000-S0-5000NO/SF-5000-SNO/S-5000NH3 Sensor Detecting Range SelectionDetecting range(ppm)/SizeMiniatureCompactSlimStandard0-50NH3/CR-500-100NH3/MR-100
NH3/MR-100-2E0-200NH3/CR-200NH3/SR-200-SNH3/SR-2000-500NH3/MR-5000-1000NH3/MR-1000
NH3/MR-1000-2ENH3/CR-1000NH3/SR-1000-SNH3/SR-10000-2000NH3/MR-20000-5000NH3/MR-5000NH3/CR-50000-10000NH3/MR-10000NH3/CR-10000
Module ParametersModule typeGM-I2(3)-M/C/S-**-****/G/P/F/FLDetected gasToxic gas Detecting principleElectrochemistrySamplingDiffusing pump flange threadResponding time30s~40s(of the sensor)Module accuracy≤±3%FS(actual concentration, higher accuracy depends on specified sensors)Module repeatability≤±2% FSModule linear error≤±2% FSModule zero temperature drift≤±2% (FS/year)Module operating temperature-40~80°CModule humidity0-95%RH(non-condensation)Sensor operating temperature-20°C~50°CSensor humidity0-90%RH(non-condensation)Signal outputTTL/4-20mA /RS485 (two or three wire)Transmitting distance1000 meters(RS485)Operating voltageDC 12-36VMaximum power≤0.8WSize80*48mmExplosion proofIntrinsic safeConnection cableRVVP3 x 1.5mm²
Module applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control