Business Type:
Manufacturer/Factory,Trading Company
Business Range:
High Voltage Tester, HV PD Test Set, HV Resonant Test System, Cable Fault Locator, SF6 Gas ..
Establishment:
2012
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea), Australia, Domestic
OEM/ODM Service
Sample Available

High Voltage Tester, High Voltage Equipment, Withstand Voltage Tester manufacturer / supplier in China, offering Automatic AC High Voltage Test Set/Multi-channel Withstand Voltage Tester, GDKC-12A High Voltage Circuit Breaker Tester Transformer Test Device, GDHL-200B Factory Price Automatic Contact Resistance Tester Microhmmeter and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Test Instrument Other Test Instrument High Voltage Phase Detector/Audio Wireless Phase Detector (GDHX-9500)

High Voltage Phase Detector/Audio Wireless Phase Detector (GDHX-9500)

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $600.00/ Piece
Local Area: Wuhan, Hubei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Type: Test and Measurement Instruments
Detectable Voltage Range: 10V-500kV
Wireless Transmission Distance: Range of visibility 150 Meters
High Voltage Phase Detector/Audio Wireless Phase Detector (GDHX-9500)Product Description

1.1 General Purpose

The "Wireless Phase Detector" is mainlyusedinelectric powerlines,substation phase andphase sequence calibration, withmainfunctionsincludingelectrical inspection,phasecalibration and phase sequencemeasurement and so on. Thisproductadoptsdoubleshieldingandentirely newdigitalcircuits,withstrong anti-interference,infullaccordance with(EMC)standards,adaptedtovarious electromagneticinterferencesituations.

The high voltage phase signal of measured lead will be launched out directly after treatment, the handset will receive and make phase comparison, determine the results after the phase calibration, real-time display phase angle difference and vector.

This product uses wireless transmission technology, thereby achieving safe and reliable, fast and accurate, different voltage levels (10V-500KV) are all applicable. When checking the grid structure, enable to accurately identify the relative phase of the different leads for the three-phase connected line, without any electrical connection between two measurement components, it makes the application of the measurement device is very flexible and safe.

1.2 Security Matters

Adopts wireless transmission technology, its basic working principle is real-time phase comparison.Please observe and follow the regulation to use of this product, in order to ensure the safe operation of the instrument, and note the ends of X and Y detector are not allowed to take withstand voltage test.The metal head parts of the insulating rodis strictly prohibitedto contact withany objects during the test.Please comply with the country's power industry safety regulations of preventive test for safety tools and products.Please pay attention to the training and examination for staffs who work on high-voltage live lines or near the high-voltage lines.Phase calibration on live equipment must be carried out by insulating rod.

Note: The safe usage length and test standards of insulating rod for "Wireless Phase Detector".(Excerpting from "Electrical safety working regulations of State Grid Corporation".)1.Safety distance between staff and the charged body during live operation.

Voltage Level10kV35kV66kV110kV220kV330kV500kVSafety Distance0.4M0.6M0.7M1.0M1.8M2.2M3.4M
2.The minimum effective insulation length of insulating rod during live operation.Voltage Level10kV35kV66kV110kV220kV330kV500kVMinimum effective insulation length0.7M0.9M1.0M1.3M2.1M3.1M4.0M
Note: The test standard of insulating tools checking test (subsection):applying power frequency 75kV to each 300mm for 1min: qualified as no breakdown, no flashover and over-heat.
Specifications
Test voltage10V-500kV, different voltage level are applicableAccuracySelf-calibrating ≤±3°Sampling speed10 times/sDate and time settingsAdjusting date and time, make it easy for users to browse, view the historical dataBack-light time settingsNormally on, normally off, 0-999s can be set by user selfAuto power off settings0-999s can be set by user selfIn-phase qualitative≤20° as in-phase (phase threshold within 0-90°, can be set by user self. The system default is 20°.)Out-phase qualitative>20° ((phase threshold within 0-90°, can be set by user self. The system default is 20°.)Field calibration functionenable to carry out on-site calibration for measured lead, ensure the accuracy of phase angleTransmission distance between handset and X, Y detectorX≤150m, Y≤150mMultiple model design, with strong applicability, more safe and convenientUnique human-computer interaction interface, simple operation;FCC antenna design, the signal is stronger and easier to penetrate the blocking of wall, door or barrier;Double shielding, strong an-ti interference, in full accordance with EMC standards;Charts and data display, more convenient and easy to read;Qualitative measurement:Display by sound and light signal;Quantitative measurementReal-time display phase angle difference, error≤5°;Phase sequence calibrationPositive phase sequence, negative phase sequence (120°, 240°);