Business Type:
Manufacturer/Factory,Trading Company
Business Range:
AC and DC High Voltage Test Equipment, Power Transformer Test Equipment, Instrument ..
Establishment:
2012
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea)
OEM/ODM Service
Sample Available

Contact Resistance Tester, micro ohm Tester, contact Resistance Test manufacturer / supplier in China, offering China Manufacturer Portable Color LCD display Built in Micro Printer 200A Circuit Beaker Contact Resistance Meter Loop Resistance micro ohm Tester, Chinese manufacturer portable DC System Ground Fault Detector, 24V 48V 110V 220V DC system Ground Fault Test Equipment and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Test Instrument Test Machine Turn Ratio Group Tester Calibration Equipment

Turn Ratio Group Tester Calibration Equipment

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $24.00/ Piece
Local Area: Wuhan, Hubei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Power: Electricity
Voltage Output: 220V
LCD Display: With LCD Display

The device is used to test the turn ratio accuracy, resolution and group ( including Z type) of the instrument transformer turn ratio testers with accuracy at 0.5 or below 0.05. It is composed of two parts: standard three phase PT and inductive voltage divider. The PT is used to test ratio group test function of the ratio tester, inductive voltage divider is used to test the accuracy and resolution of the ratio tester
Technical indicators:Primary voltage : 200VSecondary voltage: 0~200VRated load: 0VAInductive voltage divider accuracy: 0.0005 classRatio Uncertainty: 3x10-6Weight: 10KgStandard three phase PT accuracy: 0.05 class
Functions
1. Turn ratio test by divider
Turns ratio range can be preset as the reciprocal of any value during 1.111111~0.0000001. When turns ratio is 1,2,5,10,20,50,100,200,500,1000,2000,2500, the dial scaleof the inductive voltage divider should be selected as 1.000000,0.5000000,0.2000000,0.1000000,0.0500000,0.0200000,0.0100000,0.0050000,0.0020000,0.0010000,0.00050000,0.00040000. UAX rated voltage is 200V, it can work under 20%~100% of rated voltage.
2. Resolution test
Usually set the divider value during 0.1000000~0.0999900 which mean turn ratio to be 10.000~11.100. The display value of the ratio tester should obviously change when the divider set value changes.
3. straight-through test
It means the test when divider set value is 1.000000. When make this test, the primary UAB will be directly connected with secondary terminal ( a, b terminal), that is to say, UAB=Uab. It is 1/1 self-checking. But when the ratio tester is the type for which such straight test are not allowed, inductive isolated winding can be used to do1/1 isolation test.
3. Ratio group test
The standard three phase PT can make 12 groups for group testing of the ratio tester. Turns ratio can be 10 or 100 or 1000 total 3 choices. PT each single phase error less than 0.05%
4. Z type group test
Total 10 groups(△/Z or Y/Z) for Z type, the turn ratio to be 100. PT each phase secondary winding error less than 0.05%