Business Type:
Manufacturer/Factory,Trading Company
Establishment:
2012
R&D Capacity:
OEM, ODM, designandmanufacture
Terms of Payment:
LC, T/T, D/P, cash
OEM/ODM Service
Sample Available

Hydro Power, Generator, Power Plant manufacturer / supplier in China, offering Turbine Generator / Hydro Generator / Water Generator, Hydro Power Generator, Small Francis Hydro Turbine/Water Turbine Generator and so on.

1
    YRS
General Supplier
Supplier Homepage Industrial Equipment & Components Power & Generating Sets Other Generators China Adjustable Runner Blades Bulb Tubular Turbine Bulb Turbine

China Adjustable Runner Blades Bulb Tubular Turbine Bulb Turbine

Get Latest Price
Min. Order / Reference FOB Price
10 Set Contact Supplier
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, cash
Water Turbine: Tubular
Shaft Type: Horizontal
Frequency: 50Hz or 60Hz

Adjustable Runner Blades Bulb Tubular Turbine , Bulb Turbine

Technical Parameters

Water Head: 2m~25m

Large Discharge

Power: 50KW~5MW

Tubular Turbine

The tubular turbines are the best selection for exploitation of tidal power and hydraulic power with extremely low heads and extremely large flow rates. They have large discharge,high specific and high efficiency, and need less excavation.They have been classified into Bulb, Pit, Siphon and S" types in the light of their structural types.

The tubular turbine requires less space than other turbines, a saving in civil costs is realized due to a smaller powerhouse and shallow requirements for the draft tube,which is equipped with adjustable wicket gates and adjustable runner blades. This arrangement provides the greatest possible flexibility in adapting to changing net head and changing demands for power output; because the gates and blades can he adjusted to their optimum openings.

Accessory equipment:

Governors: YDT, YWT, DST and TY series.

Excitations: SCR excitations, DC excitaiton systems, AC brushless exciters.

Oil pressure supply systems, control facilities, automatic control systems and so on.

Company Information
Our company is an experienced manufacture and engineering Company in small scale hydro power equipment ( 100Kw to 50Mw). We play the role of manufacture and EPC contractor and could supply water to wire equipments and services. As turbine manufacture more than 50 years experience.
We provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.

1.Water Turbine Generator Unit Design & SUPPLY
2.Hydropower equipment supply
3.Feasibility study of hydropower project
4.Manufacture
5.Installation & Supervision
6.Commissioning and Training service
7. Hydro power plant rehabilitant

8. Hydro power plant spares supply
9.Services

Our factory occupies 560,000 square meters of land, which includes 18 workshops, over 320 sets of heavy and precision producing and testing machinery; scientific research development center in the southern China, and various testing facilities. We have a general technical staff of 380 and 135 senior technical professionals.

Reference List of Some Export ProjectsNo.Country and Power Station Exported toTechnical ParametersTypeQtyDate of contract1HPP2
GuatemalaRated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480VCJA475-W-80/2x6.5
SFW1000-8/118012013.062 Pakistan Type:HL855a
Runner diameter:1750mm27Mw spare runners 12013.063UKRated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-55/1x712013.034turkeyRated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x8.5
SFW500-8/99012013.055Sri LankaRated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400VHLA550-WJ-62
SFW1000-6/118012013.056CongoRated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x9.5
SFW700-8/118012013.057
EcuadorRated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KVCJC601-W-100/1x5
SFW1980-6/143022012.128
Philippines Rated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440VZD-LH-160
SF320-36/215012012.129
GuatemalaRated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440VCJA475-W-80/2x9
SFW614-12/1180
CJA475-W-80/2x6.5
SFW302-12/99022012.1110UKRated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-55B/1x8.512012.1111 UKRated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400VHL110-WJ-4212012.1112UKRated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1113UKRated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1114UKRated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1115 HPP1
Guatemala Rated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440VHLA575c-WJ-56
SFW600-8/99022012.816UKRated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-40/1x9
SFW100-8/59012012.0417EcuadorRated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440VHL220-WJ-50
SFW470-8/99012012.0418Italy Rated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400VHL110-WJ-42
HLD54-WJ-4022012.0319 Pakistan Type:HL855a
Runner diameter:1750mm27Mw spare runners 32011.1120ITALYRated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA475-W-80/2x6.5
SFW250-10/85022011.0621ItalyRated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA475-W-85/1x9.5
SFW715-8/118032011.0522 UKRated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-42/1x10
SFW100-8/59012011.0323HPP1
AlbaniaRated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KVCJA475-W-105/2x7.5
SFW2150-8/173012010.1224 HPP2
AlbaniaRated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KVCJA475-W-115/2x8
SFW3000-8/173012010.1225 Italy Rated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD41-WJ-42
HLD74-WJ-6022010.1226
Afghanistan Rated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400VHL295-LJZ-50
SF500--6/85052010.1227
PakistanRated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kVCJA475-W-100/2x10
SFW1500-10/143022010.0828 HPP1
VietnamRated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kVHL69-LJ-205
SF37500-10/360022010.0229
MozambiqueRated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x9
SFW570-8/99012010.0430
Pakistan Rated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kVHLA696-WJ-68
SFW1000-8/118032010.0331 Italy Rated head:35m
Rated flow:4.25m³/s
Frequency:50HzHLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/99032010.0132Italy Rated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kVCJA475-W-110/2x8.5
SFW1600-10/173022009.0733GeorgiaRated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm4000KW Pelton runner change 32009.0634
VietnamRated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kVHLA883-LJ-155
SF17000-12/325022009.01