Business Type:
Manufacturer/Factory,Trading Company
Establishment:
2012
R&D Capacity:
OEM, ODM, designandmanufacture
Terms of Payment:
LC, T/T, D/P, cash
OEM/ODM Service
Sample Available

Hydro Power, Generator, Power Plant manufacturer / supplier in China, offering Turbine Generator / Hydro Generator / Water Generator, Hydro Power Generator, Small Francis Hydro Turbine/Water Turbine Generator and so on.

1
    YRS
General Supplier
Supplier Homepage Industrial Equipment & Components Power & Generating Sets Hydro Generator China Hydro Turbine Water Turbine Turbina De Agua for Hydropower

China Hydro Turbine Water Turbine Turbina De Agua for Hydropower

Get Latest Price
Min. Order / Reference FOB Price
10 Piece Contact Supplier
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, cash
Size: Medium
Type: Horizontal Hydro Generator
Specification: CE / IEC
Hydro Turbine//Water Turbine/Turbina De Agua
Quick Detail:
Output Power: 50Kw to 50Mw
Rate Head:2m-1200m
Type:Francis, Pelton, Turgo, Kaplan, Tubular

Frequency:50HZ or 60HZ

Voltage: 400V,3.3KV,6.3KV,10.5KV or customized

Material: stainless steel
Shaft type:Horizontal or Vertical
high efficiency,long service life


Our service:
Fuchun Industry Development Co., ltd Shenzhen is an experienced manufacture and engineering Company in small scale hydro power equipment ( 50Kw to 50Mw). We play the role of manufacture and EPC contractor andcould supply water to wire equipments and services.
Fuchun has a experienced and professional team to work for site survey, civil work design and power system design. Also there is a strong after sale service to serve at different projects in the world.
We can provide customers with the complete package, from the design and manufacture of the turbine, generator and control equipment through to installation, commissioning and ongoing repair and maintenance.
1.Water Turbine Generator Unit Design & SUPPLY
2.Hydropower equipment supply
3.Feasibility study of hydropower project
4.Manufacture
5.Installation & Supervision
6.Commissioning and Training service
7. Hydro power plant rehabilitant
8. Hydro power plant spares supply
9.Services
Our main procucts as below:
1.Main Product kinds
1).Kaplan: fixed blade type and adjustable blade type turbines; are ranging from 3 to 45m in water head,100kW to 30MW in capacity and 0.8 to 6m in runner diameter.
2).Impulse:Turgo and Pelton type; Theirs shaft arrangements are either vertical or horizontal and they may have single nozzle,twin or multi-nozzles;are ranging from 80 to 1,000m in water head,200kW to 20MW in capacity and 0.55 to 2.3 in runner diameter.
3).Tubular: They have been classified into Bulb, Pit, Siphon and"S" types in the light of their structural types;ranging from 2 to 25m in water head, 200KW to 16MW in capacity,and 0.8m to 5.8m in runner diameter.
4).Francis:Vertical and horizontal type;are ranging from 10 to 300m in water head,100kW to 50MW in capacity and 0.35 to 4.0 m in runner diameter.

2.Accessory equipment:
Inlet valves:Hydraulic / electric control butterfly valves, ball valves, gate valves .
Governors: YDT, YWT, DST and TY series.
Excitations: SCR excitations, DC excitaiton systems, AC brushless exciters.
Oil pressure supply systems, control facilities, automatic control systems and so on.

We are also committed to fulfill all essential requirements with respect to quality, health, safety and continuously aim to reduce the harmful impact on the environment.
Our factory occupies 560,000 square meters of land,which inculdes 18 workshops,over 320 sets of heavy and precision producing and testing machinery;scientific research development center in the southern China,and various testing facilities.we also hold close ties with several research institutions and universities in this field in order to maintain advanced technology and to develop new products.More than 20 kinds of our products have been granted national or provincial technical progress and excellent products awards.We fully carry out the ISO9001 quality management system.Our products can meet IEC standard and CE requirements.
In 60 years of the company history, we designed and manufactured a large mount of hydro turbine generators, not only for domestic China but also export to more than 30 counties, such as South America,Guatemala,Ecuador,Congo,Pakistan, USA, Canada, Cuba, Germany, Austria, Turkey, North Korea, Uruguay, Viet Nam, Burma, Nepal, Norway, Denmark, Belgium, Russia, Georgia, Bulgaria, Bhutan, France, UK, Italy, etc.

Our company sincerely welcomes all clients, partners, and friends from all over the world to contact us for business co-operation. We believe that our efforts will bring you and us a win-win situation.

Reference List of Some Export ProjectsNo.Country and Power Station Exported toTechnical ParametersTypeQtyDate of contract1Latin America 12013,122Latin AmericaRated head:305m
Rated flow:0.385m³/s
Frequency:60Hz
Outgoing line voltage:480VCJA475-W-80/2x6.5
SFW1000-8/118012013.063South AsiaType:HL855a
Runner diameter:1750mm27Mw spare runners 12013.064Europe Rated head:73.8m
Rated flow:0.1325m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-55/1x712013.035EuropeRated head:203m
Rated flow:0.312m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x8.5
SFW500-8/99012013.056South AsiaRated head:88m
Rated flow:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400VHLA550-WJ-62
SFW1000-6/118012013.057West AfricaRated head:210m
Rated flow:0.423m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x9.5
SFW700-8/118012013.058
Latin AmericaRated head:925m
Rated flow:0.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KVCJC601-W-100/1x5
SFW1980-6/143022012.129
Southeast AsiaRated head:4m
Rated flow:10m³/s
Frequency:60Hz
Outgoing line voltage:440VZD-LH-160
SF320-36/215012012.1210
Latin AmericaRated head:128m
Rated flow:0.6+0.3m³/s
Frequency:60Hz
Outgoing line voltage:440VCJA475-W-80/2x9
SFW614-12/1180
CJA475-W-80/2x6.5
SFW302-12/99022012.1111EuropeRated head:48.51m
Rated flow:0.351m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-55B/1x8.512012.1112EuropeRated head:47.48m
Rated flow:0.38m³/s
Frequency:50Hz
Outgoing line voltage:400VHL110-WJ-4212012.1113EuropeRated head:25.44m
Rated flow:0.332m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1114Europe Rated head:35.19m
Rated flow:0.3m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1115Europe Rated head:37.82m
Rated flow:0.291m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD54-WJ-5012012.1116Latin AmericaRated head:60m
Rated flow:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440VHLA575c-WJ-56
SFW600-8/99022012.817EuropeRated head:58.1m
Rated flow:0.169m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-40/1x9
SFW100-8/59012012.0418Latin AmericaRated head:38m
Rated flow:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440VHL220-WJ-50
SFW470-8/99012012.0419EuropeRated head:43m
Rated flow:0.59m³/s
Frequency:50Hz
Outgoing line voltage:400VHL110-WJ-42
HLD54-WJ-4022012.0320South AsiaType:HL855a
Runner diameter:1750mm27Mw spare runners 32011.1121EuropeRated head:134m
Rated flow:0.25m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA475-W-80/2x6.5
SFW250-10/85022011.0622EuropeRated head:228m
Rated flow:0.4m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA475-W-85/1x9.5
SFW715-8/118032011.0523EuropeRated head:61.8m
Rated flow:0.221m³/s
Frequency:50Hz
Outgoing line voltage:400VXJA-W-42/1x10
SFW100-8/59012011.0324Europe Rated head:379.7m
Rated flow:0.685m³/s
Frequency:50Hz
Outgoing line voltage:10.5KVCJA475-W-105/2x7.5
SFW2150-8/173012010.1225Europe Rated head:461.6m
Rated flow:0.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KVCJA475-W-115/2x8
SFW3000-8/173012010.1226EuropeRated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400VHLD41-WJ-42
HLD74-WJ-6022010.1227
Middle AsiaRated head:36m
Rated flow:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400VHL295-LJZ-50
SF500--6/85052010.1228
South AsiaRated head:206m
Rated flow:0.89m³/s
Frequency:50Hz
Outgoing line voltage:6.6kVCJA475-W-100/2x10
SFW1500-10/143022010.0829Southeast AsiaRated head:385m
Rated flow:11.24m³/s
Frequency:50Hz
Outgoing line voltage:13.8kV(37.5Mw)HL69-LJ-205
SF37500-10/360022010.0230
East AsiaRated head:206.8m
Rated flow:0.358m³/s
Frequency:50Hz
Outgoing line voltage:400VCJA237-W-80/1x9
SFW570-8/99012010.0431
South AsiaRated head:47.5m
Rated flow:2.62m³/s
Frequency:50Hz
Outgoing line voltage:6.6kVHLA696-WJ-68
SFW1000-8/118032010.0332EuropeRated head:35m
Rated flow:4.25m³/s
Frequency:50HzHLA696-WJ-82
SFW800-12/1430
HLJF2504-WJ-56
SFW400-8/99032010.0133EuropeRated head:265m
Rated flow:0.734m³/s
Frequency:50Hz
Outgoing line voltage:6.3kVCJA475-W-110/2x8.5
SFW1600-10/173022009.0734EuropeRated head:289m
Rated flow:1.775m³/s
Nozzle No.:2
Bucket No.: 20
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm4000KW Pelton runner and shaft spares 32009.0635
Southeast AsiaRated head:86.2m
Rated flow:22.5m³/s
Frequency:50Hz
Outgoing line voltage:10.5kV(17Mw) HLA883-LJ-155
SF17000-12/325022008.01